Assessing the Efficacy of CARDIOgoniometry (CGM) to Determine Physiologically Significant Stenosis in Patients With Stable Coronary Artery Disease in Comparison to Fractional FLOW Reserve - CARDIOFLOW
NCT ID: NCT02815631
Last Updated: 2022-08-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
30 participants
INTERVENTIONAL
2015-09-30
2016-10-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
FFR is an angiographic technique which measures the physiological significance of a coronary stenosis and trial data has shown that basing management decisions on this data improves prognosis. However FFR studies are expensive and invasive, whereas CGM is painless and simply involves placing 4 sticky pads to the patient's chest / back and is similar to an ECG (heart tracing). The investigators want to see whether we can use this new method to find out whether treatment with coronary angioplasty would be of benefit. If so, then in the future, clinicians could use this method (CGM) rather than pressure wire assessment (FFR). This would have several advantages; in particular, it can be easily performed in the clinic and avoids the need to use an expensive pressure wire.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Devices Evaluating Fractional Flow Reserve in Coronary Arteries
NCT03052803
Fractional Flow Reserve Versus Angiographically Guided Management to Optimise Outcomes in Unstable Coronary Syndromes
NCT01764334
Clinical Usefulness of Fractional Flow Reserve Measurement for Significant Stenosis in Proximal Coronary Artery
NCT02475291
Evaluation of Diagnostic Accuracy, Safety, and Cost-Effectiveness of the Non-Invasive Cardiolens FFR-CT Pro Method to Measure the Fractional Flow Reserve in Diagnostics of Chronic Coronary Syndromes Versus the Standard Diagnostic Modalities.
NCT04777513
Sensor-equipped Ultrathin Pressure Microcatheter Versus Pressure Wire for FFR Measurement
NCT03541577
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Last year in the UK 202 098 patients underwent coronary angiography to determine whether they had significant coronary artery disease. However, it is well recognised that, even with orthogonal views, angiography is limited in terms of its ability to determine the functional importance of coronary lesions. In particular those lesions judged to be 50-70% stenosed may not necessarily cause ischaemia as this depends on factors such as the lesion length and, importantly, the size of the territory supplied by the vessel.
There have been several studies that have demonstrated the clinical utility of evaluating such lesions with FFR. The measurement of FFR is an index of the physiological significance of a coronary stenosis and is defined as the ratio of maximal blood flow in a stenotic artery to normal maximal flow. It is calculated by comparing the ratio of the aortic pressure and the pressure distal to the coronary stenosis during maximal hyperaemia. These pressures are measured by introducing a coronary pressure guide wire into the artery and hyperaemia is induced by giving an infusion of adenosine intravenously. An FFR ratio of \<0.80 indicates that the coronary stenosis is causing significant ischaemia and would benefit from PCI. This has since been incorporated into ESC clinical guidelines on myocardial revascularisation.
However this is an invasive procedure and the pressure wires are relatively expensive compared to standard angioplasty wires. On the contrary, CGM is a cheap and non-invasive technique that can be easily applied. The aim of the proposed study is to assess whether CGM may be able to aid clinicians in identifying if a coronary stenosis is physiologically significant at inducing myocardial ischaemia in conjunction with standard coronary angiography.
CGM is form of 3D vector electrocardiography which can provide quantitative analysis of myocardial depolarisation and repolarisation. It has been shown to be more sensitive and specific than standard 12-lead ECG at diagnosing stable coronary artery disease. Furthermore, other work has showed CGM to be more sensitive than 12-lead ECG at detecting patients with ACS. More recently in 2012, further work found that CGM was more sensitive and specific than the 12 lead ECG at identifying abnormal myocardial perfusion scans (MPS). FFR validity was initially based on a comparison with MPS and therefore we hypothesise that CGM may be comparable to FFR.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Cardiogoniometry (CGM)
Every patient involved in the study will undergo a series of CGM recordings whilst having their FFR procedure. These recordings will all be done whilst they are in the catheterisation laboratory and will be taking at the following points during the procedure.
1. First baseline recording - taken when the patient first enters the catheterisation laboratory and is prepped for their procedure.
2. Second baseline recording - taken when the FFR guide wire is in place in the coronary artery being assessed.
3. Maximal hyperaemia recording - this will be taken when the patient is at maximal hyperaemia during their adenosine infusion for their FFR procedure.
The patients involvement will then be finished in the study and will be cared for as per clinical practice.
If the CGM records a result of anything less than 0, it will be regarded as a positive result.
Cardiogoniometry (CGM)
Fractional flow reserve (FFR)
Every patient involved in the study will undergo an FFR assessment of their coronary arteries. These recordings will all be done whilst they are in the catheterisation laboratory. They will have the following recordings:
1. A baseline FFR will be recorded once the pressure wire has been advanced down the coronary artery being assessed.
2. Maximal hyperaemia FFR will be recorded during adenosine infusion.
An FFR ratio of \<0.80 will be regarded as a positive result.
Fractional Flow Reserve (FFR)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Cardiogoniometry (CGM)
Fractional Flow Reserve (FFR)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients who have been consented to undergo coronary angiography +/- PCI as part of their routine care by their clinician.
* Aged 18 or over.
* The patient has been informed of the nature of the study and has provided full written informed consent.
* FFR will be performed on study participants who demonstrate visible coronary stenosis on coronary angiography.
Exclusion Criteria
* Patients with haemodynamic instability and / or cardiogenic shock (defined as a sustained blood pressure of \<90mmHg +/- the need for inotropic support)
* Patients with an acute coronary syndrome (as defined by the European Society of Cardiology)
* Those unable to perform a good quality CGM: 1) Patients who are SOB at rest; 2) Patients with very frequent ectopic beats; 3) Patients in atrial fibrillation; 4) Patients with a heart rate \>150 beats/min
* Those patients unable to tolerate adenosine: 1) Patients with severe asthma, especially if taking oral theophylline; 2) Patients with second or third degree heart block (without a pacemaker in situ); 3) Patients with sick sinus syndrome; 4) Patients with Long QT syndrome; 5)Patients with severe hypotension (systolic pressure) \<100mmHg); 6) Patients with decompensated heart failure.
* Patients with previous coronary artery bypass graft surgery
* Patients who are unable to receive treatment with heparin
* Patients with a chronic total occlusion
* Patients with extremely tortuous or calcified vessels that are unfavourable for assessment with FFR.
* Patients with severe stenosis of the left main stem
* Patients with significant renal impairment (defined as eGFR\<30ml/min)
* Females who are or could be pregnant
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hull University Teaching Hospitals NHS Trust
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Castle Hill Hospital
Hull, East Yorkshire, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Brown OI, Clark AL, Chelliah R, Davison BJ, Mather AN, Cunnington MS, John J, Alahmar A, Oliver R, Aznaouridis K, Hoye A. Cardiogoniometry Compared to Fractional Flow Reserve at Identifying Physiologically Significant Coronary Stenosis: The CARDIOFLOW Study. Cardiovasc Eng Technol. 2018 Sep;9(3):439-446. doi: 10.1007/s13239-018-0354-1. Epub 2018 Apr 12.
Related Links
Access external resources that provide additional context or updates about the study.
Cardiogoniometry Compared to Fractional Flow Reserve at Identifying
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
15/YH/2071
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.