Mean Systemic Filling Pressure and Heart Performance Predicting Fluid Responsiveness in Aortic Valve Replacement

NCT ID: NCT02778620

Last Updated: 2019-12-18

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

27 participants

Study Classification

OBSERVATIONAL

Study Start Date

2013-08-31

Study Completion Date

2015-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to determine fluid responsiveness in critically ill patients by measuring mean systemic filling pressure on the intensive care unit.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The assessment of the cardiovascular state in critically ill patients is subject to difficulties in terms of the fact that several hemodynamic parameters, for example mean arterial blood pressure (MAP) and cardiac output (CO) supply insufficient information about the circulating volume and cardiac performance. There is a clinical need to adequate determination of intravascular volume status and therefore reliable predictors of fluid responsiveness are highly relevant. However, in determining the fluid status of a patient, the lack of appreciation of the venous side of the circulation persists today, which is greatly due to the inability to appropriately assess the venous side of the circulation. The importance of the venous part of the circulation is moreover reflected by the fact that an increase in venous resistance does reduce CO many times more than a similar increase in arterial resistance. Mean systemic filling pressure (Pms), which is defined as the pressure equal to the pressure which would be measured if the heart should suddenly stop pumping and all (arterial and venous) the pressures in the entire circulatory system should be brought to equilibrium instantaneously, is a good, complete and reliable reflection of the total intravascular fluid compartment. Passive leg raising (PLR) represents a "self-volume challenge" that predicts preload responsiveness and the transient hemodynamic changes on venous return can be directly monitored in ventilated patients, provided that there is an intact circulation, in order to test the amount of volume responsiveness.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cardiac Output, High

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Volume responsiveness mean systemic filling pressure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Aortic Valve Replacement

Post Anaesthetic Care Unit (PACU) patients treated with aortic valve replacement (AVR) are highly eligible for this study.These are patients with an indication for fast track treatment (PACU) post-cardiac surgery with a good left ventricular ejection fraction without significant co-morbidity. The final decision for PACU-classification is taken by the responsible anaesthesiologist and intensivist in close collaboration with the cardiothoracic surgeon performing the operation, as well as the cardiologist.

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients must be older than 18 years, and must be equipped with a pulse-contour cardiac output system with a central venous catheter.
* Patients will be subsequently connected to the hemodynamic monitoring device Navigatorâ„¢.
* In those patients with clinical signs of inadequate tissue perfusion, passive leg raising and standardized fluid challenge will be performed.

Exclusion Criteria

* Patients with assist devices (e.g. intra aortic balloon pump, Impella®, ECMO), patients with arrhythmias (either atrial of ventricular) will be excluded from the study.
* Also, patients with inguinal impairment or contraindications for a passive leg raising will be excluded (such as deep venous thrombosis or elastic compression stocking), head trauma, an increase intra-abdominal pressure suspected by clinical context and examination as well as patients with absolute contraindications for fluid challenge.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Erasmus Medical Center

OTHER

Sponsor Role collaborator

Catharina Ziekenhuis Eindhoven

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

L.P.B. Meijs

MD, PhD-candidate Intensive Care Unit / resident cardiology

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jan Bakker, MD, PhD

Role: STUDY_CHAIR

Erasmus Medical Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Catharina Hospital

Eindhoven, North Brabant, Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

M12-1270

Identifier Type: -

Identifier Source: org_study_id