Automated Adjustment of Inspired Oxygen to Maintaining Regional Cerebral Oxygenation in Preterm Infants on Respiratory Support
NCT ID: NCT02748447
Last Updated: 2017-04-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
60 participants
INTERVENTIONAL
2016-04-30
2017-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Aim of this study: to evaluate the efficacy of automated FiO2 adjustment in maintaining SpO2 within a target range and in reducing the risk of cerebral tissue hypo-oxygenation due to SpO2 fluctuations in preterm infants on invasive or non invasive respiratory support with supplemental oxygen.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effects of Automated Adjustment of FiO2 on Cerebral and Arterial Oxygenation in Preterm Infants
NCT01942473
Application of Lung Near-Infrared Spectroscopy (NIRS) in Preterm Infants
NCT05961670
Effects of Closed-loop Automatic Control of FiO2 in Extremely Preterm Infants
NCT03168516
Impact of Different Modes of Noninvasive Ventilation on Regional Oximetry and Hemodynamics in Premature Newborn
NCT01942967
Successful Extubation and Noninvasive Ventilation in Preterm ≤ 1500g Terms
NCT02396693
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Aim of this study: to evaluate the efficacy of automated FiO2 adjustment in maintaining SpO2 within a target range and in reducing the risk of cerebral tissue hypo-oxygenation due to SpO2 fluctuations in preterm infants on invasive or non invasive respiratory support with supplemental oxygen.
Methodology: multicenter randomized cross-over clinical trial. The study will be carried out for almost 1 year .
Study centers: 7 Italian Neonatal Intensive Care Units (NICUs) Number of subjects: 60 infants to have a \>90% power, with an alpha of p=0.01, of detecting a 5% difference in %-time in the target range and a 50% difference in both SpO2 hyperoxic and hypoxic %-time.
Diagnosis and main inclusion criteria: preterm infants of 25+0-28+6 weeks of gestational age, requiring invasive or non invasive respiratory support and supplemental oxygen.
Other enrollment requirements: All infants will be enrolled between \>72 hours (end of transition period) and \</= 7 days. Expected to remain of the current mode of support for the 48-hour intervention period. Infants with major congenital anomalies, haemodynamic instability (patent ductus arteriosus-PDA) or requiring catecholamines treatment, clinical evidence of seizures or ongoing sepsis (positive blood culture) during the study, or within 24 hours prior of enrollment, will be excluded.
Study product:AVEA ventilator with closed-loop inspired oxygen control (CLiO2) automated FiO2 control option. An additional sensor will be attached to the infant's forehead for continuous measurement of cerebral tissue oxygen saturation (rStO2) with 5100C NIRS oximeter, Covidien.
Duration:24 hours each of manual control and CLiO2 control. Reference therapy:Manual control of FiO2 provided according to standardized guidelines.
Statistical Methodology: repeated measures mixed linear model with control from sequence and ventilation mode.
Concurrent safety oversight:Independent Data Safety Monitoring Board, with blinded review every 6 months or 50% enrollment, and after 15 subjects.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
SUPPORTIVE_CARE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
A-FiO2
24 hours in automated FiO2 adjustment to maintain SpO2 within a target range
Automated FiO2 adjustment
AVEA ventilator according to SpO2 target range delivers an automated FiO2
M-FiO2
24 hours in manual adjustment of FiO2 to maintain SpO2 within a target range
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Automated FiO2 adjustment
AVEA ventilator according to SpO2 target range delivers an automated FiO2
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
72 Hours
7 Days
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
ASST Fatebenefratelli Sacco
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Gianluca Lista,MD
MD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Gianluca Lista, MD
Role: PRINCIPAL_INVESTIGATOR
ASST-FBF-Sacco
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
V. Buzzi Childrens's Hospital - ASST FBF-SACCO
Milan, , Italy
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Kurth CD, McCann JC, Wu J, Miles L, Loepke AW. Cerebral oxygen saturation-time threshold for hypoxic-ischemic injury in piglets. Anesth Analg. 2009 Apr;108(4):1268-77. doi: 10.1213/ane.0b013e318196ac8e.
Laptook AR, Salhab W, Allen J, Saha S, Walsh M. Pulse oximetry in very low birth weight infants: can oxygen saturation be maintained in the desired range? J Perinatol. 2006 Jun;26(6):337-41. doi: 10.1038/sj.jp.7211500.
Claure N, D'Ugard C, Bancalari E. Automated adjustment of inspired oxygen in preterm infants with frequent fluctuations in oxygenation: a pilot clinical trial. J Pediatr. 2009 Nov;155(5):640-5.e1-2. doi: 10.1016/j.jpeds.2009.04.057.
van Kaam AH, Hummler HD, Wilinska M, Swietlinski J, Lal MK, te Pas AB, Lista G, Gupta S, Fajardo CA, Onland W, Waitz M, Warakomska M, Cavigioli F, Bancalari E, Claure N, Bachman TE. Automated versus Manual Oxygen Control with Different Saturation Targets and Modes of Respiratory Support in Preterm Infants. J Pediatr. 2015 Sep;167(3):545-50.e1-2. doi: 10.1016/j.jpeds.2015.06.012. Epub 2015 Jul 2.
Other Identifiers