Trial Outcomes & Findings for Investigation of Two New 1-piece Ostomy Products in People With an Ileostomy or Colostomy (NCT NCT02675634)
NCT ID: NCT02675634
Last Updated: 2017-10-16
Results Overview
Subjects will evaluate the fit to body for each product by answering the question "how was the baseplates ability to fit the body contours in the area around the stoma?" The question is answered using an ordinal 5 point scale ranging from very poor to very good. The result shown below shows the fraction of subject who answered 'Good' or' Very Good' to the question.
COMPLETED
NA
55 participants
14 +/- 2 days
2017-10-16
Participant Flow
The subjects were recruited through the Coloplast A/S database and from hospital sites
Participant milestones
| Measure |
Test A, Test B, Subjects Own Product
The subjects first test Coloplast Test A, followed by Coloplast Test B and finally Subjects own product
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Test A, Subjects Own Product, Test B
The subjects first test Coloplast Test A, followed by Subjects own product, and finally Coloplast Test B
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Test B, Test A, Subjects Own Product
The subjects first test Coloplast Test B, followed by Coloplast Test A and finally Subjects own product
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Test B, Subjects Own Product, Test A
The subjects first test Coloplast Test B, followed by Subjects own product, and finally Coloplast Test A
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Subjects Own Product, Test A, Test B
The subjects first test Subjects own product, followed by Test A, and finally Coloplast Test B
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Subjects Own Product, Test B, Test A
The subjects first test Subjects own product, followed by Test B, and finally Coloplast Test A
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
|---|---|---|---|---|---|---|
|
Test Period 1
STARTED
|
10
|
8
|
9
|
9
|
10
|
9
|
|
Test Period 1
COMPLETED
|
10
|
7
|
8
|
8
|
10
|
9
|
|
Test Period 1
NOT COMPLETED
|
0
|
1
|
1
|
1
|
0
|
0
|
|
Test Period 2
STARTED
|
10
|
7
|
8
|
8
|
10
|
9
|
|
Test Period 2
COMPLETED
|
9
|
7
|
8
|
8
|
10
|
8
|
|
Test Period 2
NOT COMPLETED
|
1
|
0
|
0
|
0
|
0
|
1
|
|
Test Period 3
STARTED
|
9
|
7
|
8
|
8
|
10
|
8
|
|
Test Period 3
COMPLETED
|
9
|
7
|
8
|
8
|
10
|
8
|
|
Test Period 3
NOT COMPLETED
|
0
|
0
|
0
|
0
|
0
|
0
|
Reasons for withdrawal
| Measure |
Test A, Test B, Subjects Own Product
The subjects first test Coloplast Test A, followed by Coloplast Test B and finally Subjects own product
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Test A, Subjects Own Product, Test B
The subjects first test Coloplast Test A, followed by Subjects own product, and finally Coloplast Test B
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Test B, Test A, Subjects Own Product
The subjects first test Coloplast Test B, followed by Coloplast Test A and finally Subjects own product
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Test B, Subjects Own Product, Test A
The subjects first test Coloplast Test B, followed by Subjects own product, and finally Coloplast Test A
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Subjects Own Product, Test A, Test B
The subjects first test Subjects own product, followed by Test A, and finally Coloplast Test B
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
Subjects Own Product, Test B, Test A
The subjects first test Subjects own product, followed by Test B, and finally Coloplast Test A
Coloplast Test A: Test A is a new 1-piece ostomy appliance developed by Coloplast A/S
Coloplast Test B: Test B is a new 1-piece ostomy appliance developed by Coloplast A/S
Subjects own product: The comparator product is the ostomy appliance product that the subject normally uses. This could include products like SenSura , SenSura Mio, Confidence Natural, Moderma Flex and many more. data from the subject own product will be pooled so they appear as one comparator group.
|
|---|---|---|---|---|---|---|
|
Test Period 1
Adverse Event
|
0
|
1
|
0
|
1
|
0
|
0
|
|
Test Period 1
Device deficiency that did not lead to A
|
0
|
0
|
1
|
0
|
0
|
0
|
|
Test Period 2
Lack of Efficacy
|
1
|
0
|
0
|
0
|
0
|
0
|
|
Test Period 2
Adverse Event
|
0
|
0
|
0
|
0
|
0
|
1
|
Baseline Characteristics
One subject did not aswer the gender question therefore this information is missing.
Baseline characteristics by cohort
| Measure |
The Study Population
n=55 Participants
This consists of all participants who were enrolled in the study
|
|---|---|
|
Age, Continuous
|
69 years
STANDARD_DEVIATION 11.2 • n=55 Participants
|
|
Sex: Female, Male
Female
|
14 Participants
n=54 Participants • One subject did not aswer the gender question therefore this information is missing.
|
|
Sex: Female, Male
Male
|
40 Participants
n=54 Participants • One subject did not aswer the gender question therefore this information is missing.
|
PRIMARY outcome
Timeframe: 14 +/- 2 daysSubjects will evaluate the fit to body for each product by answering the question "how was the baseplates ability to fit the body contours in the area around the stoma?" The question is answered using an ordinal 5 point scale ranging from very poor to very good. The result shown below shows the fraction of subject who answered 'Good' or' Very Good' to the question.
Outcome measures
| Measure |
Test A
n=51 Participants
This is the result from all subjects evaluating Test A
|
Test B
n=54 Participants
This is the results from all the subjects evaluating Test B
|
Own Product
n=51 Participants
this is the result from all the subjects evaluating Own product.
|
|---|---|---|---|
|
Fit to Body
|
93 percentage of good or very good
|
88 percentage of good or very good
|
57 percentage of good or very good
|
Adverse Events
Test A
Test B
Own Product
Serious adverse events
| Measure |
Test A
n=52 participants at risk
This is the result from all subjects evaluating Test A
|
Test B
n=54 participants at risk
This is the results from all the subjects evaluating Test B
|
Own Product
n=51 participants at risk
this is the result from all the subjects evaluating Own product.
|
|---|---|---|---|
|
Gastrointestinal disorders
Obstibation
|
1.9%
1/52 • Number of events 1 • Adverse events were collected from subject enrollment to the subject left the study. Subjects with serious adverse events were followed until their condition was resolved.
|
0.00%
0/54 • Adverse events were collected from subject enrollment to the subject left the study. Subjects with serious adverse events were followed until their condition was resolved.
|
0.00%
0/51 • Adverse events were collected from subject enrollment to the subject left the study. Subjects with serious adverse events were followed until their condition was resolved.
|
Other adverse events
| Measure |
Test A
n=52 participants at risk
This is the result from all subjects evaluating Test A
|
Test B
n=54 participants at risk
This is the results from all the subjects evaluating Test B
|
Own Product
n=51 participants at risk
this is the result from all the subjects evaluating Own product.
|
|---|---|---|---|
|
Skin and subcutaneous tissue disorders
Peristomal skin dermatitis
|
15.4%
8/52 • Number of events 8 • Adverse events were collected from subject enrollment to the subject left the study. Subjects with serious adverse events were followed until their condition was resolved.
|
20.4%
11/54 • Number of events 12 • Adverse events were collected from subject enrollment to the subject left the study. Subjects with serious adverse events were followed until their condition was resolved.
|
7.8%
4/51 • Number of events 5 • Adverse events were collected from subject enrollment to the subject left the study. Subjects with serious adverse events were followed until their condition was resolved.
|
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place
Restriction type: LTE60