Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
25 participants
INTERVENTIONAL
2015-08-31
2018-03-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Methods Patient selection criteria will be the same that in the original COR study. All patients will be followed with a Reveal LINQ® cardiac monitor that will be implanted before ablation. The primary objective is the proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation. Secondary objectives are: AF-free survival without anti arrhythmic drugs 12 months after ablation, cumulative AF burden (number of AF episodes and percentage of time in AF) 12 months after ablation, percentage of the pulmonary veins with bidirectional block at the end of the procedure, and ablation time (from the onset of the first energy delivery to the end of the last energy delivery), procedure time (from femoral puncture to catheter removal), and fluoroscopy time.
Final results will be known 24 months after the first enrollment. Statistical analysis Continuous variables that are distributed normally according to the Shapiro-Wilk test will be presented as the mean \[standard deviation\], and the values will be compared with the t test. Continuous variables that do not follow a normal distribution will be presented as the median \[25th to 75th percentile\] and will be compared with the Mann-Whitney U test. Categorical variables between two groups with expected values \<5 will be compared with the Fisher exact test. Otherwise, categorical variables will be compared with the chi-squared test. The AF-free survival functions will be represented as Kaplan-Meier curves. Data analyses will be done with JMP® (version 9.0.1, SAS Institute Inc., Cary, NC, USA) and Stata® (version 11.0, StataCorp LP; College Station, TX, USA).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Cryoenergy Or Radiofrequency for Pulmonary Vein Isolation
NCT00969735
Cryoballoon Ablation in Patients With Longstanding Persistent Atrial Fibrillation
NCT02294929
Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation
NCT01061931
High-Density (HD) Wave Mapping in Subjects With Atrial Fibrillation as a Predictor of Recurrence After a Single Ablation Procedure Using a PVI-Only Strategy
NCT03882021
Hybrid Therapy and Heart Team for Atrial Fibrillation
NCT03737929
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The primary endpoint of the study (proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation) was met by 48% of patients treated with cryoenergy and 68% of patients treated with radiofrequency (OR 0.43 \[95% confidence interval, 0.19 to 1.0\]; P=0.05). This difference disappeared after adjustment for acute procedural outcome. In patients for whom all 4 PVs were blocked at the end of the procedure, there was no difference between group C and group R in the primary endpoint (67% versus 68%; P=0.94). Thus, the COR trial supports that: 1) complete PV conduction block is critical to the success of AF ablation; 2) despite the fact that the results of the anatomical cryoablation technique used in the COR study are superior to the previously published series of patients treated with PV cryoablation and followed by implantable monitors, results of cryoablation might be even better if we aim for PV conduction block. At present time, the availability of the Achieve® mapping catheter and the more efficient 2nd-generation cryoballoon ArcticFront Advance® catheter provides an opportunity to test a electrophysiologically guided PV cryoablation approach against conventional PV isolation with point-by-point radiofrequency ablation catheters.
The COR advance study is a non-randomized observational prospective single center study to assess the results of an electrophysiologically guided approach for PV cryoablation using the Arctic Front Advance ST® catheter together with the Achieve® mapping catheter in 25 patients with drug-refractory paroxysmal AF.
Methods
Inclusion criteria:
* Symptomatic recurrent paroxysmal AF
* \>2 episodes in the last 6 months
* Refractory to 1 or more antiarrhythmic drugs
* Anatomical pattern consisting of 4 pulmonary veins
* Willing and capable of providing informed consent
Exclusion criteria:
* Patients that are \<18 or \>75 years old
* Prior AF ablation
* Prior cardiac surgery
* Moderate to severe valvular heart disease
* Anteroposterior diameter of the left atrium \>50 mm
* Hyperthyroidism, intracardiac thrombus, contraindications for anticoagulation, concomitant acute illness, pregnancy.
* Unavailability for follow-up at our center for at least 1 year
All procedures will be performed in the Arrhythmia Unit of our Institution. Patients will need to give written informed consent to be enrolled in this study. Pre-procedural exams and pre-ablation technique will be the same that used in the COR trial. The end point of PV cryoablation will be complete bidirectional PV conduction block assessed with the Achieve® catheter. Only one ArcticFront Advance® or ArcticFront Advance ST® catheter (23 or 28 mm diameter) will be used per patient. Every cryoenergy delivery will last 240 seconds, except in case of excessive freezing (temperature ≤-65ºC with a 23 mm balloon or ≤-60º with a 28 mm balloon), diaphragmatic hypokinesia or other significant adverse event related to freezing. No bonus applications will be given if the time to effect is less than 60 seconds with a 23-mm cryoballoon catheter, or less than 90 seconds with a 28-mm cryoballoon. When the time to effect cannot be assessed, no bonus applications will be given provided that there is complete occlusion of the PV during freezing (persistent contrast staining of the PV) and the application results in PV conduction block. Otherwise, either late PV conduction block or incomplete PV occlusion during freezing will need a bonus cryoenergy delivery. If PV conduction block is not achieved, one or more additional cryoenergy applications will be given at discretion of the responsible physician. Thus, the number of cryoenergy applications will not be limited by protocol, but the use of a different size cryoballoon or conventional point-by-point ablation catheters is strongly discouraged.
Patient selection criteria will be the same that in the original COR study. All patients will be followed with a Reveal LINQ® cardiac monitor that will be implanted before ablation. The primary objective is the proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation. Secondary objectives are: AF-free survival without anti arrhythmic drugs 12 months after ablation, cumulative AF burden (number of AF episodes and percentage of time in AF) 12 months after ablation, percentage of the pulmonary veins with bidirectional block at the end of the procedure, and ablation time (from the onset of the first energy delivery to the end of the last energy delivery), procedure time (from femoral puncture to catheter removal), and fluoroscopy time.
Final results will be known 24 months after the first enrollment.
Statistical analysis Continuous variables that are distributed normally according to the Shapiro-Wilk test will be presented as the mean \[standard deviation\], and the values will be compared with the t test. Continuous variables that do not follow a normal distribution will be presented as the median \[25th to 75th percentile\] and will be compared with the Mann-Whitney U test. Categorical variables between two groups with expected values \<5 will be compared with the Fisher exact test. Otherwise, categorical variables will be compared with the chi-squared test. The AF-free survival functions will be represented as Kaplan-Meier curves. Data analyses will be done with JMP® (version 9.0.1, SAS Institute Inc., Cary, NC, USA) and Stata® (version 11.0, StataCorp LP; College Station, TX, USA).
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ArticFont Advance ST
Patients undergoing PV isolation with the ArticFont Advance ST Cryoenergy Balloon Catheter
ArticFont Advance ST Cryoenergy Balloon Catheter
PV isolation using the ArticFont Advance ST Cryoenergy Balloon Catheter
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ArticFont Advance ST Cryoenergy Balloon Catheter
PV isolation using the ArticFont Advance ST Cryoenergy Balloon Catheter
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* \>2 episodes in the last 6 months
* Refractory to 1 or more antiarrhythmic drugs
* Anatomical pattern consisting of 4 pulmonary veins
* Willing and capable of providing informed consent
Exclusion Criteria
* Prior AF ablation
* Prior cardiac surgery
* Moderate to severe valvular heart disease
* Anteroposterior diameter of the left atrium \>50 mm
* Hyperthyroidism, intracardiac thrombus, contraindications for anticoagulation, concomitant acute illness, pregnancy.
* Unavailability for follow-up at our center for at least 1 year
18 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hospital San Carlos, Madrid
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Nicasio Perez Castellano
FEA
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Unidad de Arritmias, Hospital Clínico San Carlos
Madrid, , Spain
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Perez-Castellano N, Fernandez-Cavazos R, Moreno J, Canadas V, Conde A, Gonzalez-Ferrer JJ, Macaya C, Perez-Villacastin J. The COR trial: a randomized study with continuous rhythm monitoring to compare the efficacy of cryoenergy and radiofrequency for pulmonary vein isolation. Heart Rhythm. 2014 Jan;11(1):8-14. doi: 10.1016/j.hrthm.2013.10.014. Epub 2013 Oct 5.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
AF-3064: COR ADVANCE Study
Identifier Type: -
Identifier Source: org_study_id
More Related Trials