Trial Outcomes & Findings for Clinical Evaluation of CARESTREAM Dual Energy and Digital Tomosynthesis (NCT NCT02531646)

NCT ID: NCT02531646

Last Updated: 2017-03-09

Results Overview

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

66 participants

Primary outcome timeframe

3 months

Results posted on

2017-03-09

Participant Flow

Participant milestones

Participant milestones
Measure
Predicate & Invest. DE - Human Subjects
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Predicate & Invest. DT - Human Subjects
Radiation - Fifteen to twenty (15-20) patients will receive a DR standard of care chest exam using the DRX Plus detector, and a DT exam. Each DT patient exam includes a scout image (chest PA) and a DT scan using the investigational DT SW. The DT scan is used by the DT console software to generate tomographic images. Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Predicate & Invest. DT - Phantom Images
Radiation - Eleven (11) phantoms of various anatomy will be imaged with linear tomography (LT) as predicate and DT for investigational. Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Overall Study
STARTED
37
18
11
Overall Study
COMPLETED
32
17
11
Overall Study
NOT COMPLETED
5
1
0

Reasons for withdrawal

Reasons for withdrawal
Measure
Predicate & Invest. DE - Human Subjects
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Predicate & Invest. DT - Human Subjects
Radiation - Fifteen to twenty (15-20) patients will receive a DR standard of care chest exam using the DRX Plus detector, and a DT exam. Each DT patient exam includes a scout image (chest PA) and a DT scan using the investigational DT SW. The DT scan is used by the DT console software to generate tomographic images. Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Predicate & Invest. DT - Phantom Images
Radiation - Eleven (11) phantoms of various anatomy will be imaged with linear tomography (LT) as predicate and DT for investigational. Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Overall Study
equip. image processing issue
5
1
0

Baseline Characteristics

Clinical Evaluation of CARESTREAM Dual Energy and Digital Tomosynthesis

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Predicate & Invest. DE - Human Subjects
n=37 Participants
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Predicate & Invest. DT - Human Subjects
n=18 Participants
Radiation - Fifteen to twenty (15-20) patients will receive a DR standard of care chest exam using the DRX Plus detector, and a DT exam. Each DT patient exam includes a scout image (chest PA) and a DT scan using the investigational DT SW. The DT scan is used by the DT console software to generate tomographic images. Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Predicate & Invest. DT - Phantom Images
n=11 Participants
Radiation - Eleven (11) phantoms of various anatomy will be imaged with linear tomography (LT) as predicate and DT for investigational. Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Total
n=66 Participants
Total of all reporting groups
Age, Customized
> 18 years
37 years
n=93 Participants
18 years
n=4 Participants
11 years
n=27 Participants
66 years
n=483 Participants
Sex/Gender, Customized
unknown
37 participants
n=93 Participants
18 participants
n=4 Participants
11 participants
n=27 Participants
66 participants
n=483 Participants

PRIMARY outcome

Timeframe: 3 months

Population: 224 image ratings from 7 radiologist readers (32 images rated x 7 readers) for Predicate \& Invest. DE - Human Subjects arm above.

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=224 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DE Predicate PA Chest
3.4540 units on a scale
Standard Error 0.0183

PRIMARY outcome

Timeframe: 3 months

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=224 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DE Investigational Composite
3.3214 units on a scale
Standard Error 0.0242

PRIMARY outcome

Timeframe: 3 months

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=224 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DE Investigational High Energy
3.2911 units on a scale
Standard Error 0.0178

PRIMARY outcome

Timeframe: 3 months

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=224 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DE Investigational Low Energy
3.5504 units on a scale
Standard Error 0.0163

PRIMARY outcome

Timeframe: 3 months

Population: 119 image ratings from 7 radiologist readers (17 images rated x 7 readers) for Predicate \& Invest. DT Reference 1 - PA Chest arm above.

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=119 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DT Reference 1- PA Chest
3.4832 units on a scale
Standard Error 0.0228

PRIMARY outcome

Timeframe: 3 months

Population: 119 image ratings from 7 radiologist readers (17 images rated x 7 readers) for Predicate \& Invest. DT Reference 2 - PA and LAT Chest arm above.

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=119 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DT Reference 2 - PA and LAT Chest
3.5546 units on a scale
Standard Error 0.0190

PRIMARY outcome

Timeframe: 3 month

Population: 119 image ratings from 7 radiologist readers (17 images rated x 7 readers) for DT Investigational - Scout \& DT Volume.

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=119 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DT Investigational - Scout & DT Volume
3.6277 units on a scale
Standard Error 0.0230

PRIMARY outcome

Timeframe: 3 months

Population: 77 phantom image ratings from 7 radiologist readers (11 images rated x 7 readers) for Predicate \& Invest. DT - Phantom Images arm above.

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=77 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - LT Predicate Phantom Images
3.3494 units on a scale
Standard Error 0.0433

PRIMARY outcome

Timeframe: 3 months

Population: 77 phantom image ratings from 7 radiologist readers (11 images rated x 7 readers) for Predicate \& Invest. DT - Phantom Images arm above.

1-1.9-Non-diagnostic Unacceptable for diagnostic purposes. Little or no clinically usable diagnostic information (e.g., gross underexposure, system failure or extensive motion artifact). Almost all such imaging should be repeated. 2-2.9-Limited Acceptable, with some technical defect (motion artifact, body habitus/poor x-ray penetration, or patient positioning may limit visualization of some body-regions but still adequate for diagnostic purposes). Not as much diagnostic information as is typical for an examination of this type, but likely sufficient. 3-3.9-Diagnostic Image quality that would be expected routinely when imaging cooperative patients. 4-Exemplary Good, most adequate for diagnostic purposes. Image quality that can serve as an example that should be emulated.

Outcome measures

Outcome measures
Measure
Predicate & Invest. DE - Human Subjects
n=77 images
Radiation -Thirty to forty (30-40) patients will receive a DR standard of care chest exam using the DRX Plus detector and a DE exam. Each DE patient exam includes high energy and low energy image exposures using the investigational device. These images are used by the DE console software to generate additional DE images (e.g. bone and soft tissue). Radiation: Radiation - Each human subject will receive one standard of care x-ray and one Duel Energy exposure or one standard of care x-ray and one Digital Tomosynthesis exposure.
Radlex Scale for Diagnostic Quality Ratings - DT Investigational Phantom Images
3.7156 units on a scale
Standard Error 0.0268

Adverse Events

Predicate & Invest. DE - Human Subjects

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Predicate & Invest. DT - Human Subjects

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Predicate & Invest. DT - Phantom Images

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Susan Pate, RN, MS, RAC, Senior Clinical Manager

Carestream Health, Inc.

Phone: 585-627-6557

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place