Trial Outcomes & Findings for Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension (NCT NCT02489045)

NCT ID: NCT02489045

Last Updated: 2021-08-13

Results Overview

Evaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).

Recruitment status

COMPLETED

Study phase

PHASE4

Target enrollment

178 participants

Primary outcome timeframe

up to 1 day

Results posted on

2021-08-13

Participant Flow

Participant milestones

Participant milestones
Measure
SHAPE Measurement
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Overall Study
STARTED
178
Overall Study
COMPLETED
125
Overall Study
NOT COMPLETED
53
Follow-up
STARTED
21
Follow-up
COMPLETED
11
Follow-up
NOT COMPLETED
10

Reasons for withdrawal

Reasons for withdrawal
Measure
SHAPE Measurement
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Overall Study
unable to collect usable data
53
Follow-up
Lost to Follow-up
10

Baseline Characteristics

Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
SHAPE Measurement
n=125 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Age, Continuous
58 years
STANDARD_DEVIATION 12 • n=5 Participants
Sex: Female, Male
Female
45 Participants
n=5 Participants
Sex: Female, Male
Male
80 Participants
n=5 Participants
Ethnicity (NIH/OMB)
Hispanic or Latino
4 Participants
n=5 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
121 Participants
n=5 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
n=5 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
n=5 Participants
Race (NIH/OMB)
Asian
5 Participants
n=5 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
n=5 Participants
Race (NIH/OMB)
Black or African American
41 Participants
n=5 Participants
Race (NIH/OMB)
White
79 Participants
n=5 Participants
Race (NIH/OMB)
More than one race
0 Participants
n=5 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
n=5 Participants
Region of Enrollment
United States
125 participants
n=5 Participants

PRIMARY outcome

Timeframe: up to 1 day

Evaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).

Outcome measures

Outcome measures
Measure
SHAPE Measurement
n=113 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Diagnostic Accuracy of SHAPE Liver Pressure Estimates (in dB) for Diagnosing Portal Hypertension With Catheter Pressure Measurements (in mmHg) as the Reference Standard
95 diagnostic accuracy in percent

PRIMARY outcome

Timeframe: up to 1 day

Evaluate the correlation between in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg) in patients undergoing a transjugular liver biopsy.

Outcome measures

Outcome measures
Measure
SHAPE Measurement
n=113 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE Liver Pressure Estimates (in dB) Correlation With Catheter Pressure Measurements (in mmHg)
0.68 correlation coefficient

PRIMARY outcome

Timeframe: up to 2 hours

Population: Only subjects with clinically significant portal hypertension were included in the follow-up study

Determine if SHAPE measurements (in dB) can provide a quantitative, noninvasive measurement of hepatic venous pressure gradient (HVPG) to monitor disease progression or treatment response in patients identified with portal hypertension by comparing the results to repeat biopsies and/or clinical outcomes.

Outcome measures

Outcome measures
Measure
SHAPE Measurement
n=11 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min. SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patients
SHAPE values in responders
-4.01 dB
Standard Deviation 3.61
Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patients
SHAPE value in non-responders
2.33 dB
Standard Deviation 0

Adverse Events

SHAPE Measurement

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Flemming Forsberg, PhD

Thomas Jefferson University

Phone: 215-955-4870

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place