Trial Outcomes & Findings for Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension (NCT NCT02489045)
NCT ID: NCT02489045
Last Updated: 2021-08-13
Results Overview
Evaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).
COMPLETED
PHASE4
178 participants
up to 1 day
2021-08-13
Participant Flow
Participant milestones
| Measure |
SHAPE Measurement
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
|
|---|---|
|
Overall Study
STARTED
|
178
|
|
Overall Study
COMPLETED
|
125
|
|
Overall Study
NOT COMPLETED
|
53
|
|
Follow-up
STARTED
|
21
|
|
Follow-up
COMPLETED
|
11
|
|
Follow-up
NOT COMPLETED
|
10
|
Reasons for withdrawal
| Measure |
SHAPE Measurement
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
|
|---|---|
|
Overall Study
unable to collect usable data
|
53
|
|
Follow-up
Lost to Follow-up
|
10
|
Baseline Characteristics
Noninvasive Subharmonic Aided Pressure Estimation of Portal Hypertension
Baseline characteristics by cohort
| Measure |
SHAPE Measurement
n=125 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
|
|---|---|
|
Age, Continuous
|
58 years
STANDARD_DEVIATION 12 • n=5 Participants
|
|
Sex: Female, Male
Female
|
45 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
80 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
4 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
121 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
5 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
41 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
79 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
Region of Enrollment
United States
|
125 participants
n=5 Participants
|
PRIMARY outcome
Timeframe: up to 1 dayEvaluate the use of in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and in the portal vein) as a first quantitative screening modality for determining the presence of clinically significant portal hypertension in patients undergoing a transjugular liver biopsy compared to catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg as the reference standard).
Outcome measures
| Measure |
SHAPE Measurement
n=113 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
|
|---|---|
|
Diagnostic Accuracy of SHAPE Liver Pressure Estimates (in dB) for Diagnosing Portal Hypertension With Catheter Pressure Measurements (in mmHg) as the Reference Standard
|
95 diagnostic accuracy in percent
|
PRIMARY outcome
Timeframe: up to 1 dayEvaluate the correlation between in vivo subharmonic aided pressure estimation (SHAPE as the difference between the optimized subharmonic signal in a hepatic vein and catheter based hepatic-venous pressure gradient measurements (HVPG in mmHg) in patients undergoing a transjugular liver biopsy.
Outcome measures
| Measure |
SHAPE Measurement
n=113 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
|
|---|---|
|
SHAPE Liver Pressure Estimates (in dB) Correlation With Catheter Pressure Measurements (in mmHg)
|
0.68 correlation coefficient
|
PRIMARY outcome
Timeframe: up to 2 hoursPopulation: Only subjects with clinically significant portal hypertension were included in the follow-up study
Determine if SHAPE measurements (in dB) can provide a quantitative, noninvasive measurement of hepatic venous pressure gradient (HVPG) to monitor disease progression or treatment response in patients identified with portal hypertension by comparing the results to repeat biopsies and/or clinical outcomes.
Outcome measures
| Measure |
SHAPE Measurement
n=11 Participants
48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
SHAPE measurement (Sonazoid ultrasoud contrast agent): Three vials with 48 µl of Sonazoid (GE Healthcare, Oslo, Norway) microbubbles (6 ml) will be prepared and drawn into a 10 ml syringe, placed in a syringe pump. Sonazoid will be co-infused at a rate of 0.024 µl/kg body weight/minute (suspension infusion rate of 0.18 ml/kg/hour) together with a 0.9% NaCl solution infused at a rate of at least 2 ml/min.
|
|---|---|
|
Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patients
SHAPE values in responders
|
-4.01 dB
Standard Deviation 3.61
|
|
Comparing SHAPE Results With Blood Work and Concomitant Imaging in Portal Hypertension Patients
SHAPE value in non-responders
|
2.33 dB
Standard Deviation 0
|
Adverse Events
SHAPE Measurement
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place