Evaluation of the CIRCA Monitoring System in Prevention of Esophageal Lesions Following RFCA
NCT ID: NCT02467166
Last Updated: 2021-06-02
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
40 participants
INTERVENTIONAL
2015-06-30
2020-05-05
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The OneFreeze Study
NCT02217254
Catheter Ablation of Longstanding Persistent Atrial Fibrillation
NCT02929836
Prospective Evaluation of CT Guided Ablation of Cardiac Ganglionated Plexi
NCT04642976
RF Lesion Monitoring With 8mm IntellaTip MiFi XP
NCT02089672
Esophageal Damage Protection During Pulmonary Vein Ablation. Pilot Study.
NCT03832959
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
When the investigators perform a radiofrequency catheter ablation (RFCA) at UCSD, the investigators routinely use the Circa™ temperature monitor system to prevent damage to the esophagus. For this study, patients will receive an esophagoscopy, a procedure in which a flexible tube with a camera is inserted through the mouth into the esophagus. The esophagoscopy will be conducted the next day following the ablation procedure to examine the lining of the esophagus for possible lesions or damage. Patients are asked to participate in this study because they are scheduled to have an ablation for atrial fibrillation (AF). There will be approximately 40 participants in this study at the University of California, San Diego (UCSD) Cardiovascular Center. The use of the Circa™ temperature monitoring system used in standard ablation procedures at UCSD and will be used whether or not patients decide to participate in this study. Using esophagoscopy, this study will evaluate the lining of the esophagus, or swallowing tube between the throat and stomach, the day following atrial fibrillation ablation by using an endoscope, flexible tube equipped with a camera.
Patients enrolled in the study will proceed to their standard of care ablation procedure for treatment of atrial fibrillation. There will be no changes to the ablation as part of this research study. The Circa™ temperature monitor system will be used throughout the ablation as is standard clinical care for all patients receiving AF ablations at UCSD. For research purposes only, patients will undergo an esophagoscopy, or endoscopic evaluation of the esophagus, the next day following the atrial fibrillation ablation. This procedure will take 40-45 minutes, and will involve inserting a flexible probe (tube) with a camera, into the throat and esophagus (swallowing tube), where it will be inspected for any damage (thermal lesions) caused during the ablation procedure.
Following the procedure, patients will be monitored in the usual fashion in the procedure treatment unit (PTU), as is standard of care following AF ablation. Ablation patients will be discharged from the hospital in a standard manner after esophagoscopy and asked to schedule a follow-up appointment following ablation, as is standard of care. There will not be any research follow-up for this study. If for any reason patients cannot complete the ablation or esophagoscopy procedure, patient will be withdrawn from study.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Circa™ Probe
The Circa™ Probe will be used during the RFCA to monitor esophageal temperature. Following ablation, the esophagoscopy will be performed to examine the esophagus for resulting thermal lesions.
Circa™ Probe
The Circa™ probe will be used to monitor esophageal temperature and guide ablation power and duration during the RFCA procedure. Following ablation esophagoscopy will be performed to assess for esophageal lesions.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Circa™ Probe
The Circa™ probe will be used to monitor esophageal temperature and guide ablation power and duration during the RFCA procedure. Following ablation esophagoscopy will be performed to assess for esophageal lesions.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Must give written informed consent
Exclusion Criteria
* Any known esophageal disease or prior injury that would preclude esophagoscopy
* Any complications occuring during or after AF ablation that would result in esophagoscopy being an added significant risk to the patient beyond the known potential risks from the esophagoscopy
* Prior AF ablation
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Circa Scientific, Inc.
INDUSTRY
University of California, San Diego
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Greg Feld
Professor of Medicine
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Gregory Feld, MD
Role: PRINCIPAL_INVESTIGATOR
UC San Diego
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sulpizio Cardiovascular Center
La Jolla, California, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Martinek M, Bencsik G, Aichinger J, Hassanein S, Schoefl R, Kuchinka P, Nesser HJ, Purerfellner H. Esophageal damage during radiofrequency ablation of atrial fibrillation: impact of energy settings, lesion sets, and esophageal visualization. J Cardiovasc Electrophysiol. 2009 Jul;20(7):726-33. doi: 10.1111/j.1540-8167.2008.01426.x. Epub 2009 Feb 2.
Dagres N, Anastasiou-Nana M. Prevention of atrial-esophageal fistula after catheter ablation of atrial fibrillation. Curr Opin Cardiol. 2011 Jan;26(1):1-5. doi: 10.1097/HCO.0b013e328341387d.
Halm U, Gaspar T, Zachaus M, Sack S, Arya A, Piorkowski C, Knigge I, Hindricks G, Husser D. Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias. Am J Gastroenterol. 2010 Mar;105(3):551-6. doi: 10.1038/ajg.2009.625. Epub 2009 Nov 3.
Sause A, Tutdibi O, Pomsel K, Dinh W, Futh R, Lankisch M, Glosemeyer-Allhoff T, Janssen J, Muller M. Limiting esophageal temperature in radiofrequency ablation of left atrial tachyarrhythmias results in low incidence of thermal esophageal lesions. BMC Cardiovasc Disord. 2010 Oct 26;10:52. doi: 10.1186/1471-2261-10-52.
Zellerhoff S, Ullerich H, Lenze F, Meister T, Wasmer K, Monnig G, Kobe J, Milberg P, Bittner A, Domschke W, Breithardt G, Eckardt L. Damage to the esophagus after atrial fibrillation ablation: Just the tip of the iceberg? High prevalence of mediastinal changes diagnosed by endosonography. Circ Arrhythm Electrophysiol. 2010 Apr;3(2):155-9. doi: 10.1161/CIRCEP.109.915918. Epub 2010 Mar 1.
Carroll BJ, Contreras-Valdes FM, Heist EK, Barrett CD, Danik SB, Ruskin JN, Mansour M. Multi-sensor esophageal temperature probe used during radiofrequency ablation for atrial fibrillation is associated with increased intraluminal temperature detection and increased risk of esophageal injury compared to single-sensor probe. J Cardiovasc Electrophysiol. 2013 Sep;24(9):958-64. doi: 10.1111/jce.12180. Epub 2013 Jun 7.
Feld GK, Tate C, Hsu J. Esophageal temperature monitoring during AF ablation: multi-sensor or single-sensor probe? J Cardiovasc Electrophysiol. 2013 Dec;24(12):E24. doi: 10.1111/jce.12305. Epub 2013 Nov 14. No abstract available.
ASGE Standards of Practice Committee; Evans JA, Early DS, Fukami N, Ben-Menachem T, Chandrasekhara V, Chathadi KV, Decker GA, Fanelli RD, Fisher DA, Foley KQ, Hwang JH, Jain R, Jue TL, Khan KM, Lightdale J, Malpas PM, Maple JT, Pasha SF, Saltzman JR, Sharaf RN, Shergill A, Dominitz JA, Cash BD; Standards of Practice Committee of the American Society for Gastrointestinal Endoscopy. The role of endoscopy in Barrett's esophagus and other premalignant conditions of the esophagus. Gastrointest Endosc. 2012 Dec;76(6):1087-94. doi: 10.1016/j.gie.2012.08.004. No abstract available.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol: Part 1
Document Type: Study Protocol: Part 2
Document Type: Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
150018
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.