MRI Imaging of Retromuscular Hernia Repair With CICAT Visible®
NCT ID: NCT02460029
Last Updated: 2021-01-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
10 participants
OBSERVATIONAL
2015-05-31
2021-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Magnetic Resonance Imaging of Mesh Position After Ventral Hernia Repair
NCT02177214
Preperitoneal Umbilical Mesh Area
NCT05576753
MRI Imaging of Ipsilateral Retromuscular Access
NCT03380312
Visible vs. Non-Visible Mesh in Underlay Positon After Repair of Umbilical Hernias
NCT03200405
Prospective Study Of A Size Tailored Approach To Repair Umbilical And Epigastric Primary Ventral Hernias
NCT01639118
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Repair of ventral hernias always involves a scientific discussion about placing the "optimal mesh", the "optimal" mesh position or the "optimal" fixation method of the mesh. Today, there are a lot of meshes available of different materials, different textures, in different sizes and with different properties. The choice of the "right" mesh strongly depends on the sort of hernia and on the choice of the surgeon.
Furthermore, it is known that the majority of implanted meshes shrink to an extent, which may be of disadvantage for the patient. This has already been demonstrated in several animal studies, but clinical information on the mesh shrinkage is rare and mostly a result from revised surgery.
Most meshes for repair of abdominal hernia defects, based on polymeric textile, are invisible to conventional imaging techniques, inclusive "magnetic resonance imaging" (MRI). The textile company FEG Textiltechnik GmbH, Germany, has developed a unique method which allows imaging of the mesh in vivo in the MRI. For this purpose, these unique meshes contain an amount of iron particles. The particles are incorporated into the filaments, which are subsequent warp knitted to the mesh structure.
In a similar setting, the IMAP study, the visibility of the IPOM® mesh up to 13 months after laparoscopic ventral hernia repair will be investigated. Preliminary results from this study have shown a clear visibility and a promising outcome using this mesh.
PURPOSE:
The aim of this study is the visualization of the mesh surface and the confirmation with MRI scan at 1 month and 13 months after standardized retromuscular incisional hernia repair with the visible CICAT mesh (Dynamesh®).
The investigators want to show that with this type of mesh it is possible to visualize the mesh after retromuscular placement in vivo in a safe manner.
Furthermore, the positioning of the mesh, mesh shrinkage or mesh shifting will be monitored with this technique. This provides long-term benefit and provides early treatment possibilities in case of post-operative complications related to the mesh position. Furthermore, by means of dynamic MRI measurements the mesh elasticity will be evaluated in both directions longitudinal as well as transversal.
These results will provide information about the degree of mesh incorporation and the mechanical behavior of the tissue-mesh compound.
PROCEDURES
Hernia Repair:
* Introduction of the visible CICAT mesh (Dynamesh®) via laparotomy and retromuscular positioning of the mesh with a minimum overlap with the hernia defect of at least 5 cm in all directions.
* All patients will receive a standardized pain treatment protocol. Analgesics used will be checked. Visual analog scale (VAS) for pain will be measured at 4 hours, 8 hours, 12 hours, 16 hours, 20 hours and 24 hours post-operatively and every 12 hours thereafter until discharge of the patient.
* Pain medication after discharge will be monitored and checked with the patient at each consultation.
Clinical follow-up evaluation of all patients will be performed by the principal investigator.
MRI measurement will be performed at 1 and 13 months post-operatively.
MRI scan method:
Used gear: Philips Ingenia CX 1.5 Tesla. Measurements will be performed in head first prone position and if not possible in head first supine position. Prone position is preferred because of less motion artefacts from respiration and aortic pulsation, less tendency of intestinal gas accumulation against the abdominal wall producing additional signal voids. Hence the differentiation with the hypointense mesh can be difficult.
There is no use of contrast material during the investigation. Preferably, the examination will be conducted in sober state i.e. patient should not eat for 2 hours before the examination. This is to reduce the risk of post prandial hyper-peristaltic.
DATA PROTECTION AND PRIVACY OF THE PATIENT All information about this study will be collected in the EuraHS Registry. The data will be entered into the EuraHS platform with a coded number, MOONCAT\_01, MOONCAT\_02, ...
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ventral hernia
Visualization of the mesh surface and the confirmation with MRI scan at 1 month and 13 months after standardized retromusculare incisional hernia repair with the visible CICAT mesh (Dynamesh®).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Emergency surgery (incarcerated hernia)
* Clean-contaminated or contaminated procedures
* ASA score\> 4
* Pregnancy
* No patient Informed Consent
* Life expectancy of less than 2 years
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Duomed
INDUSTRY
Algemeen Ziekenhuis Maria Middelares
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Filip Muysoms
Head of the Department of Surgery
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Filip Muysoms, MD. PhD
Role: PRINCIPAL_INVESTIGATOR
Algemeen Ziekenhuis Maria Middelares
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
AZ Maria Middelares
Ghent, , Belgium
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Hansen NL, Ciritsis A, Otto J, Busch D, Kuhl CK, Kraemer NA. Utility of Magnetic Resonance Imaging to Monitor Surgical Meshes: Correlating Imaging and Clinical Outcome of Patients Undergoing Inguinal Hernia Repair. Invest Radiol. 2015 Jul;50(7):436-42. doi: 10.1097/RLI.0000000000000148.
Ciritsis A, Hansen NL, Barabasch A, Kuehnert N, Otto J, Conze J, Klinge U, Kuhl CK, Kraemer NA. Time-dependent changes of magnetic resonance imaging-visible mesh implants in patients. Invest Radiol. 2014 Jul;49(7):439-44. doi: 10.1097/RLI.0000000000000051.
Hansen NL, Barabasch A, Distelmaier M, Ciritsis A, Kuehnert N, Otto J, Conze J, Klinge U, Hilgers RD, Kuhl CK, Kraemer NA. First in-human magnetic resonance visualization of surgical mesh implants for inguinal hernia treatment. Invest Radiol. 2013 Nov;48(11):770-8. doi: 10.1097/RLI.0b013e31829806ce.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
MoonCat Study
Identifier Type: -
Identifier Source: org_study_id
More Related Trials