Optic Nerve Sheath Diameter as a Screening Test for Increased Intracranial Pressure

NCT ID: NCT02338284

Last Updated: 2015-06-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

100 participants

Study Classification

OBSERVATIONAL

Study Start Date

2014-10-31

Study Completion Date

2015-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Patients admitted to the ICU may have delayed awakening after their critical illness has resolved. Though most either are due to metabolic causes or delayed elimination of sedative medications, more serious pathologies such as intracranial hemorrhage, ischemic stroke, and vasogenic edema may also be the cause of coma. These pathologies all result in increases in intracranial pressure (ICP) with cerebral edema. Identifying elevated intracranial pressure elevations have so far, relied on invasive monitoring techniques requiring placement of an intracranial or intraventricular catheter.

The optic nerve sheath diameter (ONSD) has been described as a highly sensitive (88-94%) and specific (85% - 94%) noninvasive technique of identifying increased intracranial pressures in patients with brain trauma, intracranial bleeding or stroke\[1-4\]. This method requires placement of an ultrasound probe on the patient's closed eyelid and then a direct measurement of the diameter of the optic nerve sheath at a pre-specified distance from the globe. A value greater than 58 mm has been shown to correlate significantly with an increased ICP (\> 20 cm H20); r = 0.71, p\<0.001 \[5\].

The investigators hypothesize that bedside ultrasound measurement of the ONSD is a simple screening test for increased intracranial pressure and can be used to rapidly and efficiently identify patients in the ICU who have coma due to an increase in intracranial pressure. The investigators propose to carry out an observational trial to determine the predictive ability of the Optic Nerve Sheath Diameter for cerebral edema/ increased intracranial pressure and to compare it with the results of neuroimaging (CT and/or MRI).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Patients admitted to the ICU may have delayed awakening after their critical illness has resolved. Though most either are due to metabolic causes or delayed elimination of sedative medications, more serious pathologies such as intracranial hemorrhage, ischemic stroke, and vasogenic edema may also be the cause of coma. These pathologies all result in increases in intracranial pressure (ICP) with cerebral edema. At this stage, the usual workup includes brain CT scans, MRI or EEG. These tests require transporting the patient from the ICU to the Radiology department, a process that may not be possible for an unstable, critically ill patient. Identifying elevated intracranial pressure elevations have so far, relied on invasive monitoring techniques requiring placement of an intracranial or intraventricular catheter.

The optic nerve attaches to the globe posteriorly and is wrapped in a sheath that contains cerebrospinal fluid. The optic nerve sheath is contiguous with the dura mater and has a trabeculated arachnoid space through which cerebrospinal fluid slowly percolates. Pressure increases around the brain are therefore transmitted to around the optic nerve and increase the diameter of the optic nerve sheath. This optic nerve sheath diameter (ONSD) has been described as a highly sensitive (88-94%) and specific (85% - 94%) noninvasive technique of identifying increased intracranial pressures in patients with brain trauma, intracranial bleeding or stroke\[1-4\]. This method requires placement of an ultrasound probe on the patient's closed eyelid and then a direct measurement of the diameter of the optic nerve sheath at a pre-specified distance from the globe. A value greater than 58 mm has been shown to correlate significantly with an increased ICP (\> 20 cm H20); r = 0.71, p\<0.001 \[5\].

We hypothesize that bedside ultrasound measurement of the ONSD is a simple screening test for increased intracranial pressure and can be used to rapidly and efficiently identify patients in the ICU who have coma due to an increase in intracranial pressure.

Objectives:

To determine the role of bedside ONSD measurement by ultrasound in the evaluation of comatose patients in the ICU.

METHODS:

* Study Design: Prospective, Observational study
* Study Sample:

* Inclusion criteria: Consecutive, adult patients already admitted to the critical care service and in whom a cause of coma is not determined.
* Exclusion criteria: obvious ocular trauma, patients on sedative or narcotic infusions.

Variables to be measured:

Independent variables:

Demographic identifiers; age, gender, comorbidity, admitting diagnosis, APACHE II scores, SAPS II scores

Dependent (Outcome) variables:

1. Diagnosis of cerebral edema/ elevated intracranial pressure as measured by Optic nerve sheath diameter
2. Diagnosis of cerebral edema/ elevated intracranial pressure as measured by neuroimaging
3. ICU mortality

Materials \& Methodologies:

1. Screening \& Enrollment of patients:

1. All ICU patients will be screened for enrollment.
2. For patients meeting the inclusion criteria, informed consent will be obtained from the patient or family members at bedside.
3. Demographic information will be collected in Case Record Forms (Appendix 2: Sample CRF)
4. Ultrasound examinations will be carried out and results entered into a CRF.
2. Technique of ONSD ultrasound measurement from Reference 6.

* A high resolution 7.5 -10 MHz linear array ultrasound transducer probe will be used. A large amount of standard water-soluble ultrasound transmission gel will be applied to the patient's closed eyelid. The globe will be scanned in the transverse plane.
* The ONSD will be measured at a predefined point 3 mm posterior to the globe in both eyes.
* Measurement of the ONSD for both eyes will be done and the average the two measurements will be taken.
* A value \> 58mm (from reference 1) will be considered as indicative of increased ICP and the primary ICU team will be informed for rapid measures to decrease ICP or urgent imaging of the CNS.
3. Statistical Methods:

1. Sample size \& Sampling: Consecutive admissions to the ICU will be enrolled. Since this is a proof of concept study, the projected sample size is 40 patients. An interim analysis will be carried out after 20 patients are enrolled and a further 20 will be enrolled as necessary
2. Analysis: Categorical variables will be reported as proportions or percentages, continuous variables as means or medians. Differences between groups will be estimated using CHI2, student t test or Mann-Whitney U test, as appropriate. A p value =0.05 will be considered significant. SPSS version 22.0 will be used for all analysis.

Ethical considerations:

* Informed Consent for ultrasonographic examination. The use of use of ultrasound for the assessment and management of critically ill patients in the ICU and emergency room is considered as standard of care and is routinely practiced in ICUs around the world. Since ultrasound evaluation has become incorporated into usual ICU practice, written consent is not required in its routine use. We therefore ask for a waiver of informed consent since we will not be performing any deviation from usual ICU care and our study is simply a collection of practice into a protocolized form.
* Research Advisory Committee (RAC) Review This protocol will be reviewed and approved by the hospital Research Advisory committee responsible for oversight of the study.

2\. Subject Confidentiality \& Protection of Rights of Control Subjects All case record forms, reports and other records will be identified only by the Study Identification Number (SID) to maintain subject confidentiality. All records will be kept in a password-protected file. All computer entry and networking programs will be done using SIDs only.

3\. Study Modification/Discontinuation The study may be modified or discontinued at any time by the primary investigators and or Research Advisory Committee as part of their duties to ensure that research subjects are protected.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coma

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ultrasound of globe

* A high resolution 7.5 -10 MHz linear array ultrasound transducer probe will be used. A large amount of standard water-soluble ultrasound transmission gel will be applied to the patient's closed eyelid. The globe will be scanned in the transverse plane.• The ONSD will be measured at a predefined point 3 mm posterior to the globe in both eyes. • Measurement of the ONSD for both eyes will be done and the average the two measurements will be taken.
* A value \> 58mm (from reference 1) will be considered as indicative of increased ICP and the primary ICU team will be informed for rapid measures to decrease ICP or urgent imaging of the CNS.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Consecutive, adult patients already admitted to the critical care service and in whom a cause of coma is not determined.

Exclusion Criteria

* Obvious ocular trauma
* Patients on sedative or narcotic infusions
Minimum Eligible Age

14 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

King Faisal Specialist Hospital & Research Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Nawal Salahuddin

Consultant Physician

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

nawal salahuddin, MD,FCCP

Role: PRINCIPAL_INVESTIGATOR

King Faisal Specialist Hospital & Research Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

King Faisal Specialist Hospital & Research Centre

Riyadh, Ar-Riyadh, Saudi Arabia

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Saudi Arabia

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Alaa Mohamed, MD

Role: CONTACT

966553730044

NADIA ALHARBI, MD

Role: CONTACT

966562042098

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Alaa Mohamed, MD

Role: primary

966553730044

nawal salahuddin, MD,FCCP

Role: backup

966551948786

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2141 103

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.