REPRISE Next Generation Delivery System

NCT ID: NCT02329496

Last Updated: 2018-05-24

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

38 participants

Study Classification

INTERVENTIONAL

Study Start Date

2014-12-03

Study Completion Date

2017-10-19

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

To confirm the acute performance and safety of the Lotus™ Valve with the Next Generation Delivery System for transcatheter aortic valve replacement (TAVR) in symptomatic patients with severe calcific aortic stenosis who are considered high risk for surgical valve replacement.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This clinical study is a prospective single-arm study designed to demonstrate that the acute performance and safety of the LOTUS Edge Valve System when used with the iSleeve Introducer Set or current Lotus Introducer Set are consistent with the results of the Lotus Valve System used in the REPRISE II study, when delivered and deployed in symptomatic subjects who have severe calcific aortic valve stenosis and who are at high risk for surgical aortic valve replacement (SAVR).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Stenosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Lotus Valve and LOTUS Edge Valve System

Transcatheter aortic valve replacement (TAVR) with Lotus Valve System with the Next Generation Delivery System and LOTUS Edge Valve System

Group Type EXPERIMENTAL

Lotus Valve and LOTUS Edge Valve System

Intervention Type DEVICE

Transcatheter aortic valve replacement (TAVR) with the Lotus Valve System with the Next Generation Delivery System and LOTUS Edge Valve System, with either the Lotus Introducer or iSleeve Introducer Sets

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Lotus Valve and LOTUS Edge Valve System

Transcatheter aortic valve replacement (TAVR) with the Lotus Valve System with the Next Generation Delivery System and LOTUS Edge Valve System, with either the Lotus Introducer or iSleeve Introducer Sets

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Subject is ≥70 years of age
2. Subject has documented calcific native aortic valve stenosis with an initial aortic valve area (AVA) of ≤1.0 cm2 (or AVA index of ≤0.6 cm2/m2) and either a mean pressure gradient ≥40 mm Hg or a jet velocity ≥4 m/s, as measured by echocardiography.
3. Subject has a documented aortic annulus size between ≥20 and ≤27.5 mm based on pre-procedure diagnostic imaging
4. Subject has symptomatic aortic valve stenosis with NYHA Functional Class ≥ II.
5. Subject is considered high risk for surgical valve replacement based on at least one of the following:

* Society of Thoracic Surgeons (STS) score ≥8%, and/or
* Agreement by the heart team (which must include an in-person evaluation by an experienced cardiac surgeon) that subject is at high operative risk of serious morbidity or mortality with surgical valve replacement.
6. Heart team (which must include an experienced cardiac surgeon) assessment that the subject is likely to benefit from valve replacement
7. Subject (or legal representative) understands the study requirements and the treatment procedures, and provides written informed consent.
8. Subject, family member and/or legal representative agree(s) and subject is capable of returning to the study hospital for all required scheduled follow up visits.

Exclusion Criteria

1. Subject has a congenital unicuspid or bicuspid aortic valve.
2. Subject with an acute myocardial infarction within 30 days of the index procedure (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of creatine kinase-myoglobin band (CK-MB) elevation and/or troponin level elevation).
3. Subject has had a cerebrovascular accident or transient ischemic attack within the past 6 months, or has any permanent neurologic defect prior to study enrollment.
4. Subject is on dialysis or has serum creatinine level \>3.0 mg/dL or 265 µml/L.
5. Subject has a pre-existing prosthetic heart valve (aortic or mitral) or a prosthetic ring in any position.
6. Subject has ≥3+ mitral regurgitation, ≥3+ aortic regurgitation or ≥3+ tricuspid regurgitation (i.e., subject cannot have more than moderate mitral, aortic or tricuspid regurgitation).
7. Subject has a need for emergency surgery for any reason.
8. Subject has a history of endocarditis within 12 months of index procedure or evidence of an active systemic infection or sepsis.
9. Subject has echocardiographic evidence of intra-cardiac mass, thrombus or vegetation.
10. Subject has Hgb \<9 g/dL, platelet count \<50,000 cells/mm3 or \>700,000 cells/mm3, or white blood cell count \<1,000 cells/mm3.
11. Subject is receiving chronic (≥72 hours) anticoagulation therapy (warfarin), and cannot tolerate concomitant therapy with aspirin or clopidogrel (subjects who require chronic anticoagulation must additionally be able to be treated with either aspirin or clopidogrel).\*
12. Subject has active peptic ulcer disease or gastrointestinal bleed within the past 3 months, other bleeding diathesis or coagulopathy or will refuse transfusions.
13. Subject has known hypersensitivity to contrast agents that cannot be adequately pre-medicated, or has known hypersensitivity to aspirin, all thienopyridines, heparin, nickel, titanium, or polyurethanes.
14. Subject has a life expectancy of less than 12 months due to non-cardiac, co-morbid conditions based on the assessment of the investigator at the time of enrollment.
15. Subject has hypertrophic obstructive cardiomyopathy.
16. Subject has any therapeutic invasive cardiac procedure within 30 days prior to the index procedure (except for balloon aortic valvuloplasty and pacemaker implantation which are allowed).
17. Subject has untreated coronary artery disease, which in the opinion of the treating physician, is clinically significant and requires revascularization.
18. Subject has documented left ventricular ejection fraction \<30%.
19. Subject is in cardiogenic shock or has hemodynamic instability requiring inotropic support or mechanical support devices.
20. Subject has severe peripheral vascular disease (including aneurysm defined as maximal luminal diameter \>5 cm or with documented presence of thrombus, marked tortuosity, narrowing of the abdominal aorta, severe unfolding of the thoracic aorta or thick \[\>5 mm\] protruding or ulcerated atheroma in the aortic arch) or symptomatic carotid or vertebral disease.
21. Femoral artery lumen of \<6.0 mm for subjects requiring 23 mm valve size or \<6.5 mm for subjects requiring 27 mm valve size, or severe iliofemoral tortuosity or calcification that would prevent safe placement of the introducer sheath.
22. Current problems with substance abuse (e.g., alcohol, etc.).
23. Subject is participating in another investigational drug or device study that has not reached its primary endpoint.
24. Subject has untreated conduction system disorder (e.g., Type II second degree atrioventricular block) that in the opinion of the treating physician is clinically significant and requires a pacemaker implantation.
Minimum Eligible Age

70 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Boston Scientific Corporation

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Robert Gooley, MD

Role: PRINCIPAL_INVESTIGATOR

Monash

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Prince Charles Hospital

Chermside, Queensland, Australia

Site Status

Monash Heart

Clayton, Victoria, Australia

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Australia

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

S2332

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

REPRISE EDGE 29 mm EU Study
NCT02964962 WITHDRAWN NA
RESPOND Post Market Study
NCT02031302 COMPLETED
RESPOND EDGE Post Market Study
NCT04009720 TERMINATED