Trial Outcomes & Findings for Stage 3 Fontan Operation Liver Ultrasound Study (NCT NCT02269709)
NCT ID: NCT02269709
Last Updated: 2018-01-12
Results Overview
ARFI shear wave speed measurements were done on the right lobe of the liver. Measurement units are m/s (meters per second). A total of 8 measurements were performed on each subject at each time point.The 8 values were performed on each subject and averaged.
COMPLETED
NA
21 participants
0-6 months
2018-01-12
Participant Flow
Participant milestones
| Measure |
ARFI Ultrasound
Subjects were pediatric patients who had undergone a repair of a heart defect, called a Fontan operation. Patients underwent an ultrasound before and after the Fontan operation.
The ultrasound scan used acoustic radiation force impulse (ARFI) shear wave velocity imaging (SVI). This is a non-invasive scan that uses sound waves to create images of the liver and measure its stiffness.
|
|---|---|
|
Time of Enrollment
STARTED
|
21
|
|
Time of Enrollment
COMPLETED
|
18
|
|
Time of Enrollment
NOT COMPLETED
|
3
|
|
Follow-up #1 (24-72 Hours Post-surgery)
STARTED
|
18
|
|
Follow-up #1 (24-72 Hours Post-surgery)
COMPLETED
|
17
|
|
Follow-up #1 (24-72 Hours Post-surgery)
NOT COMPLETED
|
1
|
|
Prior to Hospital Discharge
STARTED
|
17
|
|
Prior to Hospital Discharge
COMPLETED
|
17
|
|
Prior to Hospital Discharge
NOT COMPLETED
|
0
|
|
Six Month Follow-up
STARTED
|
17
|
|
Six Month Follow-up
COMPLETED
|
5
|
|
Six Month Follow-up
NOT COMPLETED
|
12
|
Reasons for withdrawal
| Measure |
ARFI Ultrasound
Subjects were pediatric patients who had undergone a repair of a heart defect, called a Fontan operation. Patients underwent an ultrasound before and after the Fontan operation.
The ultrasound scan used acoustic radiation force impulse (ARFI) shear wave velocity imaging (SVI). This is a non-invasive scan that uses sound waves to create images of the liver and measure its stiffness.
|
|---|---|
|
Time of Enrollment
Withdrawal by Subject
|
3
|
|
Follow-up #1 (24-72 Hours Post-surgery)
Lost to Follow-up
|
1
|
|
Six Month Follow-up
Lost to Follow-up
|
12
|
Baseline Characteristics
The age of each gender group (males and females) is compared.
Baseline characteristics by cohort
| Measure |
ARFI Ultrasound
n=18 Participants
Subjects were pediatric patients who had undergone a Fontan operation. Subjects underwent an ultrasound before and after the Fontan operation. The ultrasound scan used acoustic radiation force impulse (ARFI) shear wave velocity imaging (SVI). This is a non-invasive scan that uses sound waves to create images of the liver and measure the stiffness of the tissue.
|
|---|---|
|
Age, Continuous
|
33.5 Months
STANDARD_DEVIATION 10.5 • n=18 Participants
|
|
Sex: Female, Male
Female
|
6 Participants
n=18 Participants
|
|
Sex: Female, Male
Male
|
12 Participants
n=18 Participants
|
|
Age by Sex
Age of Male Subjects
|
34 Months
n=12 Participants • The age of each gender group (males and females) is compared.
|
|
Age by Sex
Age of Female Subjects
|
33 Months
n=6 Participants • The age of each gender group (males and females) is compared.
|
PRIMARY outcome
Timeframe: 0-6 monthsPopulation: As shown in the participant flow, data was not captured for follow up time points 1 and 2 for 1 participant. At time point 3 data is only available for 5 participants.
ARFI shear wave speed measurements were done on the right lobe of the liver. Measurement units are m/s (meters per second). A total of 8 measurements were performed on each subject at each time point.The 8 values were performed on each subject and averaged.
Outcome measures
| Measure |
ARFI Ultrasound
n=18 Participants
Subjects underwent an ultrasound scan before and after the Fontan operation.
|
|---|---|
|
Shear Wave Speed (Liver Stiffness)
Liver Stiffness at baseline
|
1.18 meters per second
Standard Deviation 0.29
|
|
Shear Wave Speed (Liver Stiffness)
Liver Stiffness follow-up tim1 (24-72 hours later)
|
2.28 meters per second
Standard Deviation 0.31
|
|
Shear Wave Speed (Liver Stiffness)
Liver Stiffness follow-up time 2 (7 days later)
|
2.22 meters per second
Standard Deviation 0.38
|
|
Shear Wave Speed (Liver Stiffness)
Liver stiffness follow-up time 3 (6 months)
|
2.08 meters per second
Standard Deviation 0.24
|
SECONDARY outcome
Timeframe: Baseline and Follow Up Number 1 (approximately 24 -72 hours later)Population: Subjects who had undergone the Fontan operation and who had a central line placed. Blood pressure values were obtained from chart review.
Blood pressure in the IVC, the interior vena cava, was measured from a central line placed for patient care.
Outcome measures
| Measure |
ARFI Ultrasound
n=9 Participants
Subjects underwent an ultrasound scan before and after the Fontan operation.
|
|---|---|
|
IVC Pressure
IVC pressure before Fontan operation
|
7.2 mmHg
Standard Error 2.6
|
|
IVC Pressure
IVC pressure after Fontan operation (24-72 hours)
|
16.44 mmHg
Standard Error 3.3
|
Adverse Events
ARFI Ultrasound
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place