Prospective, Non-randomized Multi-center, Controlled Physician-initiated Trial: Rotarex Belgium In-stent Occlusion
NCT ID: NCT02212626
Last Updated: 2017-08-01
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
30 participants
INTERVENTIONAL
2014-08-31
2017-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Trial Investigating the Efficacy of the Supera Peripheral Stent System for the Treatment of the Common Femoral Artery
NCT02804113
Post-Market Clinical Follow Up of Rotarex®S Catheter
NCT04010123
Physician-Initiated Trial Investigating the BeGraft Peripheral Stent Graft System
NCT02211716
Clinical Trial Investigating the BeGraft Peripheral Plus Stent Graft System for Iliac Lesion Treatment
NCT03286361
Belgian Trial Investigating the LifeStream Stent in Complex TASC C and D Iliac Lesions
NCT03349996
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Both techniques have limitations such as the application of fibrinolytic substances and technical, impossibility of rapid and complete thrombus extraction. Therefore various mechanical devices have been introduced which involve maceration or fragmentation and removal of thrombus. The two categories of devices for mechanical thrombectomy (MT) are: (1) rotational recirculation devices which work by the vortex principle, such as the Amplatz thrombectomy catheter (ATD, Microvena, White Bear Lake, MN) or the Arrow-Trerotola PTD (Arrow International, Reading, PA); and (2) hydrodynamic (rheolytic) recirculation devices which operate on the principle of the Venturi effect, such as the Hydrolyser (Cordis, Johnson and Johnson, Miami, FL), Oasis (Boston Scientific, Galway, Ireland), and the Angiojet (RTC; Possis Medical, Minneapolis, MN) \[5-10\]. These devices are not suited for subacute occlusions of more than 7-14 days' duration. Recently, a new rotational mechanical thrombectomy catheter, the Straub Rotarex / Aspirex (Straub Medical, 7323 Wangs, Switzerland) has been introduced. This device combines the two essential effects of mechanical clot fragmentation and removal of the fragmented clot material from the vessel by negative pressure. Two studies using the Rotarex system with 38, resp. 98 patients showed a primary patency rate of 62%, resp. 54% at 6 months and described the Rotarex / Aspirex systems as an efficient and quick technique for revascularization of acute femoropopliteal de novo occlusions. A more recent publication dating from 2011 reports results from using Rotarex® catheters for treatment of in-stent reocclusions of femoropopliteal arteries. In 78 patients, the restenosis rate was calculated as 18.4% after 12 months.
The purpose of this Belgian multi-center study is to follow-up patients after recanalization with the Rotarex®S catheter system (Straub Medical) for acute and subacute femoropopliteal stent occlusions.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Rotarex
After assessment of the lesion by angiography the occlusion is intraluminally crossed with the wire according to physician's discretion. The device is introduced and the catheter is activated while its tip is still proximal to the occlusion to allow lubrication of the spiral inside the catheter with the aspirated blood. The catheter is advanced into the occlusion with occasional retraction into the already recanalized lumen. Care must be taken to achieve sufficient cooling of the catheter tip and evacuation of the debris to get an appropriate blood flow along the catheter. In order to minimize peripheral embolization of clot the distal end of the occlusion should not be passed too fast before all loose material has been sucked back into the catheter. Several passages of the occlusion may be needed to clean out all wall-adherent thrombotic material. If residual underlying stenosis of \>30% persist further endovascular treatment can be performed according to the physician's discretion.
Rotarex S
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Rotarex S
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient is \>18 years old
* Patient understands the nature of the procedure and provides written informed consent, prior to enrolment in the study
* Patient has a projected life-expectancy of at least 6 months
* Symptomatic acute or subacute stent occlusion in the femoropopliteal artery
* Target vessel diameter ≥ 3 mm and ≤ 8 mm
* Patient is candidate for thrombolytic or anticoagulation medication
* Patient is able and willing to comply with study follow-up requirements
Exclusion Criteria
* Inability of crossing lesion with guidewire
* Known active infection at the time of intervention
* Untreated flow-limiting inflow lesions
* Perioperative unsuccessful ipsilateral percutaneous vascular procedure to treat inflow disease just prior to enrolment
* Aneurysm in the target vessel
* Severe medical comorbidities (untreated CAD/CHF, severe COPD, metastatic malignancy, dementia, etc) or other medical condition that would preclude compliance with the study protocol
* Major distal amputation (above the transmetatarsal) in the study limb or non-study limb
* Septicemia or bacteremia
* Any previously known coagulation disorder, including hypercoagulability
* Contraindication to anticoagulation or antiplatelet therapy
* Patient with known hypersensitivity to heparin, including those patients who have had a previous incidence of heparin-induced thrombocytopenia (HIT) type II
* Currently participating in another clinical research trial
* The patient must be excluded in case any of the following contraindications as listed in the IFU is present:
Rotarex®S catheters must not be used in case of:
* Patient not suitable for thrombectomy
* Target vessel belonging to the vessels of the cardiopulmonary, coronary or cerebral circulations
* Use inside or via undersized or oversized vessel diameters
* Impossibility to pass the lesion completely with the guidewire
* Subintimal position of the guidewire - even if only in short segments
* Use in stents or stent grafts if the guidewire has become threaded at any point in the wire mesh of stent or stent graft or the lining of the stent graft
* The introducer sheath, the guide catheter, the guidewire or the Rotarex®S catheter sustaining any damage, especially kinking
* Target lesions situated in the fracture areas of broken stents
* Known or suspected allergy to any of the components of the system or to a medicinal product to be administered in connection with the planned procedure
* Persistent vasospasm
* Imaging by Magnetic Resonance Imaging (MRI)
* Use of a defibrillator on the patient
* Use of electrosurgery on the patient
* Veterinary purposes
* Patients with hemodynamic instability or shock
* Patients with severe coagulatory disorders
* Situations where an embolism potentially triggered by the use of the catheter may have a very harmful effect on the patient
* Use inside or via narrow vessel radii or in tortuous vessel courses (radius of curvature \< 2cm)
* Target lesion in severely calcified vessel segments
* Target lesion in aneurysmatically altered vessel segments
* Known or suspected infection, especially of the puncture site or the vessel segment being treated
* Known, unhealed pre-existing mechanical damage to the vessel wall, especially caused by surgical procedures or interventional complications
* Impossibility to achieve sufficient anticoagulation and platelet aggregation inhibition
* Patient is pregnant or nursing a child
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Flanders Medical Research Program
NETWORK
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
OLV Hospital
Aalst, , Belgium
Imelda Hospital
Bonheiden, , Belgium
AZ Sint-Blasius
Dendermonde, , Belgium
UZA
Edegem, , Belgium
RZ Heilig Hart Hospital
Tienen, , Belgium
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
FMRP-130326
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.