Trial Outcomes & Findings for Comparison of the Sensitivity and Specificity of Acoustic Angiography to the Sensitivity and Specificity of Conventional Ultrasound (NCT NCT02175628)

NCT ID: NCT02175628

Last Updated: 2019-08-05

Results Overview

To compare (using a reader study) the sensitivity and specificity of acoustic angiography to the sensitivity and specificity of conventional b-mode ultrasound in evaluation of breast lesions

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

23 participants

Primary outcome timeframe

1.5 years

Results posted on

2019-08-05

Participant Flow

Participant milestones

Participant milestones
Measure
Acoustic Angiography
All breast patients will be included in the experimental group. Acoustic Angiography: Acoustic angiography imaging involves a research high frequency ultrasound scanner (VisualSonics Vevo 770) and a prototype transducer as well as conventional b-mode ultrasound to guide the location of the imaging. The conventional ultrasound will be conducted just prior to the acoustic angiography for localization. The imaging also requires administration of Definity ultrasound contrast agent. Acoustic angiography imaging will be performed by trained medical personnel using mild compression to eliminate motion. Total imaging time is estimated to be less than 15 minutes. All image data will be de-identified and transferred for off-line analysis based on a study ID. The research images will NOT be interpreted or analyzed for clinical decisions related to the patient.
Healthy Volunteers
A volunteer group was added to the study to perfect the image acquisition techniques. Acoustic Angiography: Acoustic angiography imaging involves a research high frequency ultrasound scanner (VisualSonics Vevo 770) and a prototype transducer as well as conventional b-mode ultrasound to guide the location of the imaging. The conventional ultrasound will be conducted just prior to the acoustic angiography for localization. The imaging also requires administration of Definity ultrasound contrast agent. Acoustic angiography imaging will be performed by trained medical personnel using mild compression to eliminate motion. Total imaging time is estimated to be less than 15 minutes. All image data will be de-identified and transferred for off-line analysis based on a study ID. The research images will NOT be interpreted or analyzed for clinical decisions related to the patient.
Overall Study
STARTED
6
17
Overall Study
COMPLETED
6
17
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Comparison of the Sensitivity and Specificity of Acoustic Angiography to the Sensitivity and Specificity of Conventional Ultrasound

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Acoustic Angiography
n=6 Participants
All breast patients will be included in the experimental group. Acoustic Angiography: Acoustic angiography imaging involves a research high frequency ultrasound scanner (VisualSonics Vevo 770) and a prototype transducer as well as conventional b-mode ultrasound to guide the location of the imaging. The conventional ultrasound will be conducted just prior to the acoustic angiography for localization. The imaging also requires administration of Definity ultrasound contrast agent. Acoustic angiography imaging will be performed by trained medical personnel using mild compression to eliminate motion. Total imaging time is estimated to be less than 15 minutes. All image data will be de-identified and transferred for off-line analysis based on a study ID. The research images will NOT be interpreted or analyzed for clinical decisions related to the patient.
Healthy Volunteers
n=17 Participants
A volunteer group was added to the study to perfect the image acquisition techniques. Acoustic Angiography: Acoustic angiography imaging involves a research high frequency ultrasound scanner (VisualSonics Vevo 770) and a prototype transducer as well as conventional b-mode ultrasound to guide the location of the imaging. The conventional ultrasound will be conducted just prior to the acoustic angiography for localization. The imaging also requires administration of Definity ultrasound contrast agent. Acoustic angiography imaging will be performed by trained medical personnel using mild compression to eliminate motion. Total imaging time is estimated to be less than 15 minutes. All image data will be de-identified and transferred for off-line analysis based on a study ID. The research images will NOT be interpreted or analyzed for clinical decisions related to the patient.
Total
n=23 Participants
Total of all reporting groups
Age, Categorical
<=18 years
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
5 Participants
n=5 Participants
15 Participants
n=7 Participants
20 Participants
n=5 Participants
Age, Categorical
>=65 years
1 Participants
n=5 Participants
2 Participants
n=7 Participants
3 Participants
n=5 Participants
Age, Continuous
48 years
STANDARD_DEVIATION 14 • n=5 Participants
43 years
STANDARD_DEVIATION 17 • n=7 Participants
45 years
STANDARD_DEVIATION 17 • n=5 Participants
Sex: Female, Male
Female
6 Participants
n=5 Participants
14 Participants
n=7 Participants
20 Participants
n=5 Participants
Sex: Female, Male
Male
0 Participants
n=5 Participants
3 Participants
n=7 Participants
3 Participants
n=5 Participants
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
n=5 Participants
1 Participants
n=7 Participants
1 Participants
n=5 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
6 Participants
n=5 Participants
8 Participants
n=7 Participants
14 Participants
n=5 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
n=5 Participants
8 Participants
n=7 Participants
8 Participants
n=5 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Race (NIH/OMB)
Asian
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Race (NIH/OMB)
Black or African American
2 Participants
n=5 Participants
2 Participants
n=7 Participants
4 Participants
n=5 Participants
Race (NIH/OMB)
White
4 Participants
n=5 Participants
5 Participants
n=7 Participants
9 Participants
n=5 Participants
Race (NIH/OMB)
More than one race
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
n=5 Participants
10 Participants
n=7 Participants
10 Participants
n=5 Participants
Region of Enrollment
United States
6 participants
n=5 Participants
17 participants
n=7 Participants
23 participants
n=5 Participants

PRIMARY outcome

Timeframe: 1.5 years

Population: The data were unable to be analyzed because we could not visualize the vessels to calculate this value. The system was unable to achieve the imaging resolution to visualize the vasculature.

To compare (using a reader study) the sensitivity and specificity of acoustic angiography to the sensitivity and specificity of conventional b-mode ultrasound in evaluation of breast lesions

Outcome measures

Outcome data not reported

SECONDARY outcome

Timeframe: 1.5 years

Population: The data were unable to be analyzed because we could not visualize the vessels to calculate this value. The system was unable to achieve the imaging resolution to visualize the vasculature.

The AUC of acoustic angiography compared to the AUC of b-mode ultrasound

Outcome measures

Outcome data not reported

SECONDARY outcome

Timeframe: 1.5 years

Population: Preference Study not conducted because the imaging resolution was insufficient. The data were unable to be analyzed because we could not visualize the vessels to calculate this value. The system was unable to achieve the imaging resolution to visualize the vasculature.

To compare radiologist preference of acoustic angiography to conventional b-mode ultrasound for each lesion characteristic (shape, margins and vascularity)

Outcome measures

Outcome data not reported

SECONDARY outcome

Timeframe: 1.5 years

Population: The data were unable to be analyzed because we could not visualize the vessels to calculate this value. The system was unable to achieve the imaging resolution to visualize the vasculature.

To quantify vessel tortuosity metrics for the acoustic angiograph images, and to use these metrics to develop a model for predicting malignancy (a model-based malignancy score)

Outcome measures

Outcome data not reported

SECONDARY outcome

Timeframe: 1.5 years

Population: The data were unable to be analyzed because we could not visualize the vessels to calculate this value. The system was unable to achieve the imaging resolution to visualize the vasculature.

To compare the model-based malignancy score to the acoustic angiography reader study

Outcome measures

Outcome data not reported

Adverse Events

Acoustic Angiography

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Healthy Volunteers

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Associate Director of Clinical Research Operations, Department of Radiology

University of North Carolina at Chapel Hill

Phone: 9199664997

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place