Trial Outcomes & Findings for Comparison of Laryngeal Mask Airway Supreme and Endotracheal Tube In Patients Undergoing Gynecological Laparoscopy Surgery (NCT NCT02127632)
NCT ID: NCT02127632
Last Updated: 2017-12-21
Results Overview
The measure is the mean airway pressure (cmH2O): T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device
COMPLETED
NA
100 participants
At first and last 10 minutes of pneumoperitoneum
2017-12-21
Participant Flow
Participant milestones
| Measure |
Group ETT (Endo Tracheal Tube)
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
Laryngeal Mask Airway-Supreme: Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.
Other Names:
LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7
|
Group LM-S(Laryngeal Mask Supreme Group)
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.
Endotracheal Tube: ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
|
|---|---|---|
|
Overall Study
STARTED
|
50
|
50
|
|
Overall Study
COMPLETED
|
50
|
50
|
|
Overall Study
NOT COMPLETED
|
0
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Comparison of Laryngeal Mask Airway Supreme and Endotracheal Tube In Patients Undergoing Gynecological Laparoscopy Surgery
Baseline characteristics by cohort
| Measure |
Group ETT (Endo Tracheal Tube)
n=50 Participants
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
Laryngeal Mask Airway-Supreme: Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson \& Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.
Other Names:
LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7
|
Group LM-S(Laryngeal Mask Supreme Group)
n=50 Participants
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.
Endotracheal Tube: ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
|
Total
n=100 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Continuous
|
39.36 years
STANDARD_DEVIATION 11.52 • n=5 Participants
|
38.86 years
STANDARD_DEVIATION 11.48 • n=7 Participants
|
39.11 years
STANDARD_DEVIATION 11.45 • n=5 Participants
|
|
Sex: Female, Male
Female
|
50 Participants
n=5 Participants
|
50 Participants
n=7 Participants
|
100 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Region of Enrollment
Turkey
|
50 participants
n=5 Participants
|
50 participants
n=7 Participants
|
100 participants
n=5 Participants
|
PRIMARY outcome
Timeframe: At first and last 10 minutes of pneumoperitoneumThe measure is the mean airway pressure (cmH2O): T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device
Outcome measures
| Measure |
Group ETT (Endo Tracheal Tube)
n=50 Participants
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
Laryngeal Mask Airway-Supreme: Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson \& Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.
Other Names:
LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7
|
Group LM-S(Laryngeal Mask Supreme Group)
n=50 Participants
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.
Endotracheal Tube: ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
|
|---|---|---|
|
Mean Airway Pressures
T1
|
7 cmH20
Interval 5.0 to 9.0
|
6 cmH20
Interval 4.0 to 9.0
|
|
Mean Airway Pressures
T2
|
8 cmH20
Interval 6.0 to 12.0
|
8 cmH20
Interval 6.0 to 19.0
|
|
Mean Airway Pressures
T3
|
8 cmH20
Interval 6.0 to 12.0
|
8 cmH20
Interval 4.0 to 17.0
|
|
Mean Airway Pressures
T4
|
7 cmH20
Interval 5.0 to 11.0
|
7 cmH20
Interval 5.0 to 12.0
|
SECONDARY outcome
Timeframe: BaselineTo provide the adequate gastric distention of either the LM-Supreme or the tracheal tube, as assigned. Gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field)
Outcome measures
| Measure |
Group ETT (Endo Tracheal Tube)
n=50 Participants
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
Laryngeal Mask Airway-Supreme: Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson \& Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.
Other Names:
LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7
|
Group LM-S(Laryngeal Mask Supreme Group)
n=50 Participants
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.
Endotracheal Tube: ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
|
|---|---|---|
|
Evaluation of Gastric Distention
|
3.24 units on a scale
Standard Deviation 1.99
|
2.02 units on a scale
Standard Deviation 1.07
|
SECONDARY outcome
Timeframe: postoperative 1st and 24th hoursPatients were asked about the presence of sore throat - defined as the presence of constant pain in the throat, 1 hr and 24 hr after the end of surgery according to Visual Analogue Scale. (range min. 0, max.10; \>4 analgesia planned)
Outcome measures
| Measure |
Group ETT (Endo Tracheal Tube)
n=50 Participants
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
Laryngeal Mask Airway-Supreme: Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson \& Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.
Other Names:
LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7
|
Group LM-S(Laryngeal Mask Supreme Group)
n=50 Participants
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.
Endotracheal Tube: ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
|
|---|---|---|
|
Throat Pain According to Visual Analogue Scale
postoperative 1st hour
|
2.04 point
Standard Deviation 1.61
|
0.32 point
Standard Deviation 0.76
|
|
Throat Pain According to Visual Analogue Scale
postoperative 24th hours
|
0 point
Standard Deviation 0
|
0 point
Standard Deviation 0
|
Adverse Events
Group ETT (Endo Tracheal Tube)
Group LM-S(Laryngeal Mask Supreme Group)
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place