Comparison of BMD Measurement by DEXA to BeamMed Speed-of-Sound Measurement at Forearm in Patients With Gaucher Disease
NCT ID: NCT02067247
Last Updated: 2014-11-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
100 participants
INTERVENTIONAL
2014-02-28
2014-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The purpose of this study is to assess bone mineral density (BMD) comparability and precision using a standard Hologic DXA unit and the quantitative ultrasound-driven speed-of-sound (SOS) BeamMed technology. The physical and mechanical properties of bone that are measured by SOS are different than bone density measured by DXA and reflect bone strength and elasticity \[Goossens et al, 2008\]. The cohorts will be patients with Gaucher disease \[Zimran \& Elstein, 2010\] who currently are requested to undergo BMD evaluation only bi-annually \[Mistry et al, 2011\], partly because of the radiation of DXA scans (admittedly low relative to standard X-rays and CT). Patients with Gaucher disease are at added risk for osteonecrosis and pathological fractures but to date no biomarker or technology has been able to predict which patients are imminently at risk. Because the option of disease-specific but very costly enzyme replacement therapy (ERT) \[Barton et al, 1991\] is predicating on the estimated risk of severe disease, predicting skeletal damage (especially osteonecrosis at the femoral neck, FN) because of osteopenia or osteoporosis has clinically relevant ramifications \[Mistry et al, 2011\]. Additionally, it has been shown that there is a correlation between low BMD at the lumbar spine (LS) and anemia in patients with Gaucher disease \[Khan et al, 2012\], so that with correction of anemia with ERT it is hoped that there will be amelioration of BMD values, and this too would be worth performing at closer intervals.
The least inconvenient and shortest evaluation for BMD is at the forearm. For approximately a year, all patients at the Gaucher disease have had DXA forearm evaluations when undergoing routine testing. It is the intention of this study to prospectively compare forearm SOS results \[Olszynski et al, 2013\] with those from the standard DXA equipment with the possibility of using SOS as a quantitative measure of bone integrity on a more regular basis.
The strategy will be to measure forearm BMD by DXA and SOS by BeamMed for comparison of accuracy and comparability and secondarily to assess the values achieved at the forearm relative to standard DXA evaluations at the FN and LS.
Patients who arrive at the Gaucher Clinic for routine monitoring that includes DXA evaluation of BMD at FN, LS, and forearm will be requested to consent to undergo SunBeam evaluation at the forearm as well. The same DXA hardware and software (Hologic, Bedford, MA) will be used for all examinations as have been employed by the Gaucher Clinic since August 2011.
The SOS technology as developed by the BeamMed Company (originally, the Sunlight Ultrasound Technologies, Israel) is based on the physical property that ultrasound waves travel faster through bone than soft tissue. The bone sonometer measures the time that elapses between the axially transmitted sound generated as an inaudible high-frequency pulsed acoustic signal at a center frequency of 1.25 MHz and the first reception of a signal after it has traveled through the selected bone. This is recorded as the SOS in m/sec. The ultrasonic waves are transmitted and received by transducers embedded in the ultrasound probe. As the ultrasound wave travels, the speed, dispersion, and attenuation of the signal is influenced by the density, elasticity, and cohesiveness of the medium, so that the greater the density and elasticity of the medium, the faster the speed of propagation \[Ashman et al, 1984\].
The device consists of a desktop main unit and 3 probes of different sizes. The small probe (1.4cm x 2.7cm x 11cm), 900-1000 KHz will be used for this study. Calibration is performed each day using a standardized calibrating plastic provided by the company. The SOS is determined as the mean of 3 scans that are found to be statistically similar (coefficient of variation below 1.2%), as calculated by the software provided with the device. Based on these 3 readings, the 95th percentile of the measured SOS is determined and used for statistical analysis.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
SCREENING
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
SOS forearm test
BeamMed Speed-of-Sound bone strength test at forearm
BeamMed Speed-of-Sound bone strength test at forearm
BeamMed Speed-of-Sound bone strength test at forearm in addition to the DEXA test
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
BeamMed Speed-of-Sound bone strength test at forearm
BeamMed Speed-of-Sound bone strength test at forearm in addition to the DEXA test
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Gaucher disease type 1
* Able to undergo a DEXA test
Exclusion Criteria
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Shaare Zedek Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ari Zimran
Prof.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ari Zimran, Prof.
Role: PRINCIPAL_INVESTIGATOR
Shaare Zedek Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Shaare Zedek Medical Center
Jerusalem, Israel, Israel
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Baskin E, Dinur T, Lebel E, Tiomkin M, Elstein D, Zimran A. Comparison of Bone Mineral Density by Dual-Energy X-Ray Absorptiometry and Bone Strength by Speed-of-Sound Ultrasonography in Adults With Gaucher Disease. J Clin Densitom. 2016 Oct;19(4):465-470. doi: 10.1016/j.jocd.2015.12.002. Epub 2016 Jan 15.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
DEXA-SOS
Identifier Type: -
Identifier Source: org_study_id