Trial Outcomes & Findings for D-Dimer Determined Anticoagulation INTENSITY in Patients With Mechanical Valve Replacement (NCT NCT01996657)

NCT ID: NCT01996657

Last Updated: 2017-06-26

Results Overview

The bleeding events included cerebral hemorrhage, gastrointestinal bleeding and other major internal or external bleeding that causes death, hospitalization, or permanent injury (e.g. vision loss) or necessitates transfusion.

Recruitment status

COMPLETED

Target enrollment

772 participants

Primary outcome timeframe

Up to 24 months

Results posted on

2017-06-26

Participant Flow

Participant milestones

Participant milestones
Measure
Standard Intensity of Anticoagulation
After mechanical valve replacement,patients should be gave oral anticoagulants,such as warfarin.and The intensity of anticoagulation for this group was standard intensity (INR:2.5-3.5). Warfarin
Low Intensity and Adjusted by Elevated D-dimer
The intensity of anticoagulation maintained at low level initiatively, D-dimer testing were analyzed at 3 month later. In case of D-dimer level elevated, adjusted the intensity to standard level. Warfarin
Low Intensity Without Adjustment
The intensity of anticoagulation for this group was kept at low intensity without adjustment (INR:1.8-2.6), Warfarin
Overall Study
STARTED
250
250
248
Overall Study
COMPLETED
237
239
234
Overall Study
NOT COMPLETED
13
11
14

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

D-Dimer Determined Anticoagulation INTENSITY in Patients With Mechanical Valve Replacement

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Standard Intensity of Anticoagulation
n=237 Participants
After mechanical valve replacement,patients should be gave oral anticoagulants,such as warfarin.and The intensity of anticoagulation for this group was standard intensity (INR:2.5-3.5). Warfarin
Low Intensity and Adjusted by Elevated D-dimer
n=239 Participants
The intensity of anticoagulation maintained at low level initiatively, D-dimer testing were analyzed at 3 month later. In case of D-dimer level elevated, adjusted the intensity to standard level. Warfarin
Low Intensity Without Adjustment
n=234 Participants
The intensity of anticoagulation for this group was kept at low intensity without adjustment (INR:1.8-2.6), Warfarin
Total
n=710 Participants
Total of all reporting groups
Age, Continuous
48.8 years
STANDARD_DEVIATION 11.5 • n=5 Participants
50.4 years
STANDARD_DEVIATION 11.9 • n=7 Participants
50.1 years
STANDARD_DEVIATION 10.9 • n=5 Participants
49.8 years
STANDARD_DEVIATION 11.3 • n=4 Participants
Sex: Female, Male
Female
113 Participants
n=5 Participants
102 Participants
n=7 Participants
96 Participants
n=5 Participants
311 Participants
n=4 Participants
Sex: Female, Male
Male
124 Participants
n=5 Participants
137 Participants
n=7 Participants
138 Participants
n=5 Participants
399 Participants
n=4 Participants
Elevated D-dimer(n)
17 participants
n=5 Participants
36 participants
n=7 Participants
38 participants
n=5 Participants
91 participants
n=4 Participants

PRIMARY outcome

Timeframe: Up to 24 months

The bleeding events included cerebral hemorrhage, gastrointestinal bleeding and other major internal or external bleeding that causes death, hospitalization, or permanent injury (e.g. vision loss) or necessitates transfusion.

Outcome measures

Outcome measures
Measure
Standard Intensity of Anticoagulation
n=237 Participants
After mechanical valve replacement,patients should be gave oral anticoagulants,such as warfarin.and The intensity of anticoagulation for this group was standard intensity (INR:2.5-3.5). Warfarin
Low Intensity and Adjusted by Elevated D-dimer
n=239 Participants
The intensity of anticoagulation maintained at low level initiatively, D-dimer testing were analyzed at 3 month later. In case of D-dimer level elevated, adjusted the intensity to standard level. Warfarin
Low Intensity Without Adjustment
n=234 Participants
The intensity of anticoagulation for this group was kept at low intensity without adjustment (INR:1.8-2.6), Warfarin
Bleeding Events;
16 Participants
3 Participants
4 Participants

PRIMARY outcome

Timeframe: 24 months

The thrombotic events included valve thrombosis, transient ischemic attack, ischemic stroke, peripheral embolism, and myocardial infarction.

Outcome measures

Outcome measures
Measure
Standard Intensity of Anticoagulation
n=237 Participants
After mechanical valve replacement,patients should be gave oral anticoagulants,such as warfarin.and The intensity of anticoagulation for this group was standard intensity (INR:2.5-3.5). Warfarin
Low Intensity and Adjusted by Elevated D-dimer
n=239 Participants
The intensity of anticoagulation maintained at low level initiatively, D-dimer testing were analyzed at 3 month later. In case of D-dimer level elevated, adjusted the intensity to standard level. Warfarin
Low Intensity Without Adjustment
n=234 Participants
The intensity of anticoagulation for this group was kept at low intensity without adjustment (INR:1.8-2.6), Warfarin
Thrombotic Events
5 Participants
5 Participants
14 Participants

SECONDARY outcome

Timeframe: Up to 24 months

The deaths from all causes

Outcome measures

Outcome measures
Measure
Standard Intensity of Anticoagulation
n=237 Participants
After mechanical valve replacement,patients should be gave oral anticoagulants,such as warfarin.and The intensity of anticoagulation for this group was standard intensity (INR:2.5-3.5). Warfarin
Low Intensity and Adjusted by Elevated D-dimer
n=239 Participants
The intensity of anticoagulation maintained at low level initiatively, D-dimer testing were analyzed at 3 month later. In case of D-dimer level elevated, adjusted the intensity to standard level. Warfarin
Low Intensity Without Adjustment
n=234 Participants
The intensity of anticoagulation for this group was kept at low intensity without adjustment (INR:1.8-2.6), Warfarin
All Cause Deaths
12 Participants
4 Participants
5 Participants

Adverse Events

Standard Intensity of Anticoagulation

Serious events: 24 serious events
Other events: 0 other events
Deaths: 12 deaths

D-dimer-guided Adjustmentd of Anticoagutlation Intensity

Serious events: 9 serious events
Other events: 0 other events
Deaths: 4 deaths

Low Intensity Without Adjustment

Serious events: 20 serious events
Other events: 0 other events
Deaths: 5 deaths

Serious adverse events

Serious adverse events
Measure
Standard Intensity of Anticoagulation
n=245 participants at risk
After mechanical valve replacement,patients should be gave oral anticoagulants,such as warfarin.and The intensity of anticoagulation for this group was standard intensity (INR:2.5-3.5). Warfarin
D-dimer-guided Adjustmentd of Anticoagutlation Intensity
n=245 participants at risk
The intensity of anticoagulation maintained at low level initiatively, D-dimer testing were analyzed at 3 month later. In case of D-dimer level elevated, adjusted the intensity to standard level. Warfarin
Low Intensity Without Adjustment
n=242 participants at risk
The intensity of anticoagulation for this group was kept at low intensity without adjustment (INR:1.8-2.6), Warfarin
Blood and lymphatic system disorders
thrombotic envents
2.0%
5/245
2.0%
5/245
5.8%
14/242
Blood and lymphatic system disorders
bleeding events
6.5%
16/245
1.2%
3/245
1.7%
4/242
Cardiac disorders
Deaths from other causes
1.2%
3/245
0.41%
1/245
0.83%
2/242

Other adverse events

Adverse event data not reported

Additional Information

Dr.Litao Zhang

Wuhan Asia Heart Hospital

Phone: +862765796888

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place