The Efficacy and Safety of Accufuser Omnibus® (Elastomeric Infusion Pump); Comparative Clinical Trial

NCT ID: NCT01976494

Last Updated: 2015-06-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

86 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-10-31

Study Completion Date

2014-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Acute post-operative pain causes not only discomfort for the patient, but delays recovery by increasing the morbidity of the circulatory system, respiratory system, and immune system, so pain control is one of the important objectives in peri-operative patient management. Patient controlled analgesia (PCA) is a piece of equipment for which the patient can personally control the administration of an analgesic. It is generally used in postoperative pain management because it is a method which can heighten patient satisfaction by reducing complications and obtaining the appropriate level of pain relief. Usually, it is designed to administer an analgesic at a steady speed, and the patient can administer additional medication by pressing a button when the pain is severe. Here, to prevent complications from excessive administration of an analgesic, repeated administration is not allowed within a certain time interval. The PCA equipment can be categorized as electronic and physical according to the force which operates the drug injection pump. Electronic equipment uses electrical energy to apply vermicular movement to the fluid tube to administer the analgesic. Physical equipment is disposable equipment designed to fill an elastomer reservoir bag expanding the material, and its elasticity returns to the original length used to administer the analgesic. The physical equipment is easy to carry and movement is comfortable because there is no need for additional electronic equipment or devices. There is also no need for special training to operate the equipment, and the action mechanism is simple so there is less opportunity for malfunction. The disposable physical equipment accounts for approximately 70% of the domestic market share and it is preferred over the electronic equipment. On the other hand, contrary to the electronic equipment, the physical PCA equipment has the disadvantage of not providing information regarding the history of the equipment's use. The early physical PCA equipment was very simple and only had the function of continually administering medication at a set speed. Hence, it was not sufficient to function as 'patient controlled' pain control equipment. Then, the function of an additional administration button was added so that the patient can personally decide whether to administer an additional amount of analgesic. At the same time, the physical PCA equipment has improved to prevent excessive administration by setting a lock-out time as a safety measure. The following development was Accufuser Selectuss®, where a function was added to select the administration speed from three options. In this way, the physical PCA equipment has continued to evolve in the direction of enhancing safety, convenience, and clinical effectiveness. The advantage of pain control using PCA equipment is that the patient can personally control additional the administration of an analgesic by pressing a button. In the case of existing or imported products, it is designed to administer a bolus by pressing the button, and the pressure presses the PVC bag filled with medication under the button to administer the bolus. Compared to the intravenous route, using an epidural as a PCA administration route has superior analgesic effect, so it can reduce the amount of opioid analgesic administered. On the other hand, the disadvantage is that it has to pass through a narrow and long epidural catheter to deliver the medication to the epidural space which has a relatively higher resistance. Woo Young Medical experimented with their own product Accufuser plus® (Woo Young Medical, Korea), and the results showed that the time taken to empty the bolus bag was approximately 40-80 seconds depending on the dosage. The pressure when a person presses the bolus button on the PCA equipment was repeatedly measured to obtain a mean value, and this pressure was constantly maintained by a machine to measure the time taken to empty the bolus bag. Clinically, it is not easy to continually press the button for 40-80 seconds, so it is difficult to exclude the possibility that the bolus was not administered properly. In addition, when excessive pressure is applied, there is the possibility that the bolus bag may burst. The domestically developed products and Accufuser Omnibus® (Woo Young Medical, Korea) was developed for the purpose of supplementing bolus failure which can occur when using epidural PCA. Within the bolus module, a second elastomeric balloon is installed behind the first bolus bag so the patient does not have to press the bolus button for a long time.

Therefore, this research focused on the effectiveness and safety of the domestic product Accufuser Omnibus® (Woo Young Medical, Korea) regarding whether the bolus is sufficiently delivered when it is administered through the epidural route, and compared the results through a comparative clinical trial with imported physical PCA equipment (Infusor SV®, Baxter, USA).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Upper Gastrointestinal Cancer

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

SUPPORTIVE_CARE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

domestic PCA equipment

Patient controlled analgesia by the domestic PCA equipment

Group Type EXPERIMENTAL

The domestic PCA equipment 'Accufuser Omnibus®'

Intervention Type DEVICE

* Subject patient selection: the purpose and method of this research will be explained to the patients who satisfy the exclusion criteria before surgery, and written consent regarding research participation will be obtained.
* Use of PCA equipment by patients is determined by randomization. Regardless of the PCA equipment type, the basal rate and bolus dose are equally set to 2 mL/hr and 2 mL for the entire research period.
* Epidural PCA regime: normal saline added to 0.75% ropivacaine 40 mL and fentanyl 15-20 mcg/kg for a total volume of 100 ml.
* After pretreatment, the chest epidural catheter is mounted in the pretreatment room or operating room. The catheter tip is adjusted to be fixed between T6-7 or T7-8.
* After mounting the catheter, a test dose of 1% lidocaine 3 ml and epinephrine 1:200.000 is injected. Ten minutes later, sensory loss and skin dermatome will be checked using an alcohol swab.

imported PCA equipment

Patient controlled analgesia by imported PCA equipment

Group Type ACTIVE_COMPARATOR

Imported PCA equipment 'Infusor SV®, Baxter, USA'

Intervention Type DEVICE

* Subject patient selection: the purpose and method of this research will be explained to the patients who satisfy the exclusion criteria before surgery, and written consent regarding research participation will be obtained.
* Use of PCA equipment by patients is determined by randomization. Regardless of the PCA equipment type, the basal rate and bolus dose are equally set to 2 mL/hr and 2 mL for the entire research period.
* Epidural PCA regime: normal saline added to 0.75% ropivacaine 40 mL and fentanyl 15-20 mcg/kg for a total volume of 100 ml.
* After pretreatment, the chest epidural catheter is mounted in the pretreatment room or operating room. The catheter tip is adjusted to be fixed between T6-7 or T7-8.
* After mounting the catheter, a test dose of 1% lidocaine 3 ml and epinephrine 1:200.000 is injected. Ten minutes later, sensory loss and skin dermatome will be checked using an alcohol swab.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

The domestic PCA equipment 'Accufuser Omnibus®'

* Subject patient selection: the purpose and method of this research will be explained to the patients who satisfy the exclusion criteria before surgery, and written consent regarding research participation will be obtained.
* Use of PCA equipment by patients is determined by randomization. Regardless of the PCA equipment type, the basal rate and bolus dose are equally set to 2 mL/hr and 2 mL for the entire research period.
* Epidural PCA regime: normal saline added to 0.75% ropivacaine 40 mL and fentanyl 15-20 mcg/kg for a total volume of 100 ml.
* After pretreatment, the chest epidural catheter is mounted in the pretreatment room or operating room. The catheter tip is adjusted to be fixed between T6-7 or T7-8.
* After mounting the catheter, a test dose of 1% lidocaine 3 ml and epinephrine 1:200.000 is injected. Ten minutes later, sensory loss and skin dermatome will be checked using an alcohol swab.

Intervention Type DEVICE

Imported PCA equipment 'Infusor SV®, Baxter, USA'

* Subject patient selection: the purpose and method of this research will be explained to the patients who satisfy the exclusion criteria before surgery, and written consent regarding research participation will be obtained.
* Use of PCA equipment by patients is determined by randomization. Regardless of the PCA equipment type, the basal rate and bolus dose are equally set to 2 mL/hr and 2 mL for the entire research period.
* Epidural PCA regime: normal saline added to 0.75% ropivacaine 40 mL and fentanyl 15-20 mcg/kg for a total volume of 100 ml.
* After pretreatment, the chest epidural catheter is mounted in the pretreatment room or operating room. The catheter tip is adjusted to be fixed between T6-7 or T7-8.
* After mounting the catheter, a test dose of 1% lidocaine 3 ml and epinephrine 1:200.000 is injected. Ten minutes later, sensory loss and skin dermatome will be checked using an alcohol swab.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* scheduled for upper abdominal surgery due to upper gastrointestinal cancer under laparotomy and plan on using epidural PCA 2
* ASA class I-II
* adults aged between 20 to 70 years
* voluntarily give written consent

Exclusion Criteria

* Patients who do not give consent to the researchers
* Patients who have allergies to the medication used for pain control, that is, the local anesthesia or opioid analgesic
* Patients who have a tendency to hemorrhage to be determined by clinical observations such as purple spots and test figures (when the PT or aPTT value is more than 1.5 times that of the normal value; platelet figures are decreased to 100,000 or lower
* Patients who have renal insufficiency or hepatic insufficiency
* Patients who do not want or fail to qualify for an epidural PCA
* Patients who are unable to express the degree of pain
* Patients who cannot understand Korean either by listening or reading
* Patients who have active infectious diseases or neurological diseases
* Patients who have an infection in the area to be punctured to mount the epidural catheter
Minimum Eligible Age

20 Years

Maximum Eligible Age

70 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Small and Medium Business Administration

UNKNOWN

Sponsor Role collaborator

Yonsei University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Departmnent of Anesthesiology and Pain Medicne Severance Hospital, Yonsei University Health System

Seoul, , South Korea

Site Status

Countries

Review the countries where the study has at least one active or historical site.

South Korea

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1-2013-0035

Identifier Type: -

Identifier Source: org_study_id