Pulmonary Artery Sealing Using the HARMONIC ACE+ Shears(HS) for VATS Lobectomy
NCT ID: NCT01975623
Last Updated: 2015-11-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
47 participants
INTERVENTIONAL
2013-09-30
2015-04-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Although VATS lobectomy has been proven to be effective and safe in experienced hands, it is not devoid of risk. Intra-operative surgical complications can be at times catastrophic.
Currently, in spite of being a safe and effective technique in experienced hands, a minority of anatomical pulmonary resections are being performed by VATS. The technical difficulty and increased actual and perceived danger of VATS lobectomy is related to PA branch manipulation and this is the main limitation for many thoracic surgeons regarding the adoption of VATS lobectomy into their practise. Furthermore, the majority of VATS lobectomies are being performed in high volume, academic medical centers with a resultant disparity in socioeconomic status between those that undergo VATS versus open lobectomy. If we can find a way to decrease the manipulation required by the surgeon on the PA branches, these procedures will be safer, less stressful for the surgeon and therefore more prevalent for anatomical pulmonary resections.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
After resection and removal of the resected specimen, the specimen will be examined ex-vivo, out of the operative field in a non-sterile field in the operative room. The lobar PA and its main segmental branches will be sharply dissected. Cannulation of a major segmental PA branch will be performed using our pressurization and monitoring device. The cannulation will be secured with a 2-0 silk suture. The vascular pressurization and recording device has been described in section E and is outlined in Figures 4 and 5. All pressure measurements will be recorded and graphed related to time from initial vascular pressurization to PA bursting pressure.
All distal segmental branches of the PA will be ligated to maintain the pressure throughout the catheterized segmental branch. An initial pressure of 25 mmHg will be obtained by inflating the vessel with normal saline. The lobar PA and the main segmental branches' diameters will be measured from vascular adventitia to adventitia. The lobar PA and the main segmental arteries will be sealed using the Harmonic Scalpel Ace+. The sealing will be performed with an intravascular pressure of 25 mmHg in order to simulate normal human PA pressures.
Following division of the PA, normal saline solution will be injected through the controlled pressure syringe pump in order to achieve an intralumenal vascular pressure until the bursting pressure is reached. Intralumenal pressure will be recorded at a frequency of 10 times per second. The bursting pressure will be recorded. Ex-vivo experimentation will take approximately 20 to 30 minutes. Burst pressure of the in-vivo endo-stapled (Endopath® ETS, 35mm, 2.5mm staples, white cartridge; Ethicon, Cincinnati, Ohio, USA) main lobar PA branches will be evaluated and recorded ex-vivo on the same specimens.
Endo-stapled vessels will be utilized as the size-matched control for energy sealed vessels in a 1:2 ratio. Allotment into the stapled or energy sealed group will be based on vascular size measurement prior to sealing. Attempts will be made to use the in-vivo staple line as the control vessel in all possible cases (size permitting) in order to increase the sample size of the energy sealed vessels.
Following vascular sealing, experimentation and recordings, the specimen will be sent for pathological evaluation of the resected lesion. All specimen manipulations will be strictly performed on the proximal main PA branches, away from the resected tumour. Care will be taken to not affect the pathological integrity of the resected lesion and its surrounding tissue and lymph nodes. Experimentation will be performed under the direct supervision of the attending thoracic surgeon in order to assure integrity of the specimen for pathological analysis.
Analysis will consist of between group comparisons of the efficacies and bursting pressure of both the energy sealed vessels (experimental group) and the endostapler-sealed vessels (control group). Vessels will be stratified by luminal diameter by millimeter. Primary outcome for analysis will be the intergroup comparisons of mean PA burst pressure by size of vessel. Intergroup differences will be compared with the student's t-test with bursting pressures entered as a continuous variable. Statistical testing for normality of data will be performed and when data is non-normal, non-parametric methods (ex: Wilcoxon Rank Sum Test…) will be used. Multivariable linear regression models will be employed in order to compare burst pressures between groups controlling for potential confounders (disease state, size of vessel sealed, age of patient, sex, pulmonary lobe, laterality, immunosupression, diabetes, vascular disease…).
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intervention Group
Pulmonary artery Energy Sealing with HARMONIC ACE+ Shears (HS) ex-vivo
HARMONIC ACE®+ Shears (HS)
We plan to evaluate the efficacy of the HS for the sealing of PAs in an ex-vivo human model. Efficacy will be measured and compared using the bursting pressure point following vascular energy sealing. Energy sealing may be superior to stapling devices as it eliminates the need for excessive tissue dissection around the pulmonary vessels, which in turn decrease the incidence of vascular injuries during VATS anatomical lung resection. All vessels will be sealed ex-vivo using the HARMONIC ACE®+ Shears (Ethicon, Cincinnati, Ohio, USA).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
HARMONIC ACE®+ Shears (HS)
We plan to evaluate the efficacy of the HS for the sealing of PAs in an ex-vivo human model. Efficacy will be measured and compared using the bursting pressure point following vascular energy sealing. Energy sealing may be superior to stapling devices as it eliminates the need for excessive tissue dissection around the pulmonary vessels, which in turn decrease the incidence of vascular injuries during VATS anatomical lung resection. All vessels will be sealed ex-vivo using the HARMONIC ACE®+ Shears (Ethicon, Cincinnati, Ohio, USA).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. patients undergoing lung explant prior to lung transplantation and
3. patients undergoing multiple visceral organ retrieval in which the lungs are not suitable for transplant.
Exclusion Criteria
* patient \< 18 years old,
* patients with hilar tumours in proximity to major PAs that might affect the integrity of the pathological vascular margin.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Centre de Recherche du Centre Hospitalier de l'Université de Montréal
OTHER
Ethicon Endo-Surgery
INDUSTRY
Centre hospitalier de l'Université de Montréal (CHUM)
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Moishe Liberman, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Centre hospitalier de l'Université de Montréal (CHUM)
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Centre Hospitalier de l'Université de Montréal
Montreal, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
12.262
Identifier Type: -
Identifier Source: org_study_id