CPG Styles Study: A Study of the Safety of the Contour Profile Gel Breast Implants (CPG Styles Study)

NCT ID: NCT01959880

Last Updated: 2016-11-11

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE3

Total Enrollment

1891 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-08-31

Study Completion Date

2015-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The CPG Styles Study is designed to demonstrate the safety of different styles of Mentor's Contour Profile Gel (CPG) breast implants in women who are undergoing primary augmentation, primary reconstruction, or revision. Safety information on the rate of capsular contracture, rupture and infection will be collected and used to determine device safety.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Silicone gel-filled breast implants were introduced in the early sixties and were in wide-scale distribution by the time the Medical Device Amendments to the Food Drug and Cosmetic Act was passed in 1976. In 1983, gel-filled breast implants were designated as Class III devices requiring pre-market approval. In May 1990, the Food and Drug Administration (FDA) published a proposed request (515(b)) for Pre-market Approval Applications (PMA) and in April 1991 published the final request. This final publication put manufacturers of gel-filled breast implants on notice that for continued marketing of gel-filled breast implants, a PMA was due to FDA in 90 days from the final publication date.

A pre-market approval (PMA) for the Mentor gel-filled breast implants was filed with the FDA in July 1991. At the FDA General and Plastic Surgery Advisory Committee meeting in November 1991, the committee recommended the submission of additional information to establish the safety and effectiveness of gel-filled breast implants.

In January 1992, the FDA Commissioner announced a voluntary moratorium of the sale of gel-filled breast implants to allow the advisory panel time to assess additional information. In April 1992, the moratorium was lifted but only for reconstruction and revision subjects. Every subject implanted had to be part of an adjunct study, in addition to being offered participation in a registry of gel-filled breast implant subjects. In order to be implanted with gel-filled implants for augmentation, women had to be enrolled in an IDE clinical trial.

In September of 2000 the Core Gel study began, leading the way to the November 2006 FDA approval of MemoryGel breast implant.

The objective of the CPG Styles Study is to determine the safety of the different styles of Mentor's Contour Profile Gel (CPG) breast implants in women undergoing breast augmentation, reconstruction, or revision.

Throughout the duration of this study, patients are required to have follow-up visits at 10 weeks post-surgery and every year after surgery through the 10th year of study completion.

Total subject population: Up to 500 new subjects, plus up to 1500 subjects rolled over from the CPG Continued Access Study will continue the 10-year follow-up under this protocol.

On September 10th, 2014, Mentor received FDA approval for the CPG Styles 312, 322, 323, and 332. The study is now closed to new subject enrollment.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Breast Augmentation Breast Reconstruction Breast Revision

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Breast Augmentation Breast Reconstruction Breast Revision Silicone Gel Contour Profile Gel Siltex CPG Styles

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Revison Augmentation

Patients in this cohort will have had previous breast augmentation with silicone or saline filled implants and are having a revision surgery to correct or improve the result of any previous breast augmentation surgery.

Group Type OTHER

The Contour Profile Gel (CPG) breast implants

Intervention Type DEVICE

The CPG mammary prosthesis is a silicone elastomer mammary device with a textured surface. The Siltex® (textured) shell consists of a smooth shell bonded to an additional layer of silicone that has a textured pattern imprinted into its surface. The Siltex® shell is textured to provide a disruptive surface for collagen interface. The CPG implant contains a gel that is a more cohesive silicone gel than that used in other Mentor gel implants. The gel is made from the same materials as Mentor's standard gel. The contour shape of the CPG is designed to provide inferior projection with reduced superior fullness. The CPG mammary prosthesis contains raised orientation marks on the anterior and posterior of the implant which may help the physician ensure proper placement.

The Contour Profile Gel is available in sizes 125cc - 690cc and 4 styles with various projection and height options in this study.

Revision Reconstruction

Patients in this cohort will have had previous breast reconstruction with silicone or saline filled implants and are having a revision surgery to correct or improve the result of any previous breast reconstruction surgery.

Group Type OTHER

The Contour Profile Gel (CPG) breast implants

Intervention Type DEVICE

The CPG mammary prosthesis is a silicone elastomer mammary device with a textured surface. The Siltex® (textured) shell consists of a smooth shell bonded to an additional layer of silicone that has a textured pattern imprinted into its surface. The Siltex® shell is textured to provide a disruptive surface for collagen interface. The CPG implant contains a gel that is a more cohesive silicone gel than that used in other Mentor gel implants. The gel is made from the same materials as Mentor's standard gel. The contour shape of the CPG is designed to provide inferior projection with reduced superior fullness. The CPG mammary prosthesis contains raised orientation marks on the anterior and posterior of the implant which may help the physician ensure proper placement.

The Contour Profile Gel is available in sizes 125cc - 690cc and 4 styles with various projection and height options in this study.

Primary Augmentation

The Augmentation cohort will include patients who have post-lactational mammary involution or wish general breast enlargement.

Group Type OTHER

The Contour Profile Gel (CPG) breast implants

Intervention Type DEVICE

The CPG mammary prosthesis is a silicone elastomer mammary device with a textured surface. The Siltex® (textured) shell consists of a smooth shell bonded to an additional layer of silicone that has a textured pattern imprinted into its surface. The Siltex® shell is textured to provide a disruptive surface for collagen interface. The CPG implant contains a gel that is a more cohesive silicone gel than that used in other Mentor gel implants. The gel is made from the same materials as Mentor's standard gel. The contour shape of the CPG is designed to provide inferior projection with reduced superior fullness. The CPG mammary prosthesis contains raised orientation marks on the anterior and posterior of the implant which may help the physician ensure proper placement.

The Contour Profile Gel is available in sizes 125cc - 690cc and 4 styles with various projection and height options in this study.

Primary Reconstruction

The Reconstruction cohort will include patients with loss of breast due to mastectomy or with deformities secondary to disease, malignancy, trauma, and congenital deformity.

Congenital deformities will include deformities of the breast itself as well as skeletal abnormalities reflected in breast deformity or asymmetry.

Group Type OTHER

The Contour Profile Gel (CPG) breast implants

Intervention Type DEVICE

The CPG mammary prosthesis is a silicone elastomer mammary device with a textured surface. The Siltex® (textured) shell consists of a smooth shell bonded to an additional layer of silicone that has a textured pattern imprinted into its surface. The Siltex® shell is textured to provide a disruptive surface for collagen interface. The CPG implant contains a gel that is a more cohesive silicone gel than that used in other Mentor gel implants. The gel is made from the same materials as Mentor's standard gel. The contour shape of the CPG is designed to provide inferior projection with reduced superior fullness. The CPG mammary prosthesis contains raised orientation marks on the anterior and posterior of the implant which may help the physician ensure proper placement.

The Contour Profile Gel is available in sizes 125cc - 690cc and 4 styles with various projection and height options in this study.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

The Contour Profile Gel (CPG) breast implants

The CPG mammary prosthesis is a silicone elastomer mammary device with a textured surface. The Siltex® (textured) shell consists of a smooth shell bonded to an additional layer of silicone that has a textured pattern imprinted into its surface. The Siltex® shell is textured to provide a disruptive surface for collagen interface. The CPG implant contains a gel that is a more cohesive silicone gel than that used in other Mentor gel implants. The gel is made from the same materials as Mentor's standard gel. The contour shape of the CPG is designed to provide inferior projection with reduced superior fullness. The CPG mammary prosthesis contains raised orientation marks on the anterior and posterior of the implant which may help the physician ensure proper placement.

The Contour Profile Gel is available in sizes 125cc - 690cc and 4 styles with various projection and height options in this study.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subject is genetic female, 18 years of age or older
* A candidate for: Primary breast augmentation (general breast enlargement), Primary breast reconstruction (for trauma, loss of breast tissue due to mastectomy, malignancy, contralateral post-reconstruction symmetry, congenital deformity, including asymmetry), or Revision surgery (previous augmentation or reconstruction with silicone-filled or saline-filled implants)
* Signs the Informed Consent
* Agrees to return device to Mentor if explant necessary
* Agrees to comply with follow-up procedures, including returning for all follow-up visits

Exclusion Criteria

* Subject is pregnant
* Has nursed a child within three months of study enrollment
* Been implanted with any silicone implant other than breast implants (e.g. silicone artificial joints or facial implants)
* Confirmed diagnosis of the following rheumatic diseases or syndromes: SLE, Sjogren's syndrome, scleroderma, polymyositis, or any connective tissue disorder, rheumatoid arthritis, crystalline arthritis, infectious arthritis, spondylarthropathies, any other inflammatory arthritis, fibromyalgia, or chronic fatigue syndrome
* Currently has a condition that could compromise or complicate wound healing (except reconstruction subjects)
* Subject in Augmentation cohort and has diagnosis of active cancer of any type. (Exception is low-grade non-metastasizing skin cancer)
* Infection or abscess anywhere in the body
* Demonstrates tissue characteristics which are clinically incompatible with implant (e.g. tissue damage resulting from radiation, inadequate tissue, or compromised vascularity)
* Possesses any condition, or is under treatment for any condition which, in the opinion of the investigator and/or consulting physicians(s), may constitute an unwarranted surgical risk
* Anatomic or physiologic abnormality which could lead to significant postoperative adverse events
* Demonstrates characteristics that are unrealistic/unreasonable with the risks involved with the surgical procedure
* Premalignant breast disease without a subcutaneous mastectomy
* Untreated or inappropriately treated breast malignancy, without mastectomy
* Are HIV positive
* Work for Mentor or the study doctor or are directly-related to anyone that works for Mentor or the study doctor
Minimum Eligible Age

18 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Mentor Worldwide, LLC

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

John Canady, M.D.

Role: STUDY_DIRECTOR

Mentor Worldwide, LLC

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Mentor Worldwide LLC

Santa Barbara, California, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

110390SS-0313-2

Identifier Type: -

Identifier Source: org_study_id