Trial Outcomes & Findings for Validity of Digital Models Obtained With iTero® and Lava Digital® in Comparison With Plaster Models. (NCT NCT01934517)

NCT ID: NCT01934517

Last Updated: 2016-02-15

Results Overview

Overjet: measured as the greatest horizontal distance from the labial surface of the lower central incisor to the most inferior point at the mesiodistal center of the upper central incisor

Recruitment status

COMPLETED

Target enrollment

25 participants

Primary outcome timeframe

one year

Results posted on

2016-02-15

Participant Flow

Participant milestones

Participant milestones
Measure
iTero, Lava Digital and Plaster Models: All Study Participants
Single-group study: 1. ITero models obtained from intraoral scans with iTero scanner 2. Plaster models obtained from alginate and PVS intraoral impressionsScan of plaster 3. Lava Digital models obtained from extraoral scans of plaster models
Overall Study
STARTED
25
Overall Study
COMPLETED
25
Overall Study
NOT COMPLETED
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Validity of Digital Models Obtained With iTero® and Lava Digital® in Comparison With Plaster Models.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
iTero, Lava Digital and Plaster Models
n=25 Participants
All study participants: iTero, LavaDigital and plaster models (single-group study)
Age, Categorical
<=18 years
23 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
2 Participants
n=5 Participants
Age, Categorical
>=65 years
0 Participants
n=5 Participants
Sex: Female, Male
Female
17 Participants
n=5 Participants
Sex: Female, Male
Male
8 Participants
n=5 Participants
Region of Enrollment
Canada
25 participants
n=5 Participants

PRIMARY outcome

Timeframe: one year

Overjet: measured as the greatest horizontal distance from the labial surface of the lower central incisor to the most inferior point at the mesiodistal center of the upper central incisor

Outcome measures

Outcome measures
Measure
iTero Models
n=25 Participants
ITero models obtained from intraoral scans with iTero scanner
Plaster Models
n=25 Participants
Plaster models obtained from alginate and PVS intraoral impressionsScan of plaster
Lava Digital Models
n=25 Participants
Lava Digital models obtained from extraoral scans of plaster models
Overjet
0.25 mm
Interval -0.65 to 1.16
0.27 mm
Interval -0.78 to 1.25
0.28 mm
Interval -0.58 to 1.2

Adverse Events

iTero Models

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Plaster Models

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Lava Digital Models

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Vincent Peloquin

U of Montreal

Phone: 514-343-6056

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place