Trial Outcomes & Findings for Periimplant Mucosa Dynamics Around Divergent and Concave Atlantis Abutment Transition Profiles (NCT NCT01871220)

NCT ID: NCT01871220

Last Updated: 2022-06-14

Results Overview

Determine if there is a difference in soft tissue peri-implant zenith changes (in millimeters) for the concave/divergent abutment sites, specifically between at delivery and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery. This measurement is taken using a standardized stereotactic digital photography system that allows for increased measurement accuracy and precision, specifically with the Canfield Dental Camera, Canfield Imaging Systems.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

61 participants

Primary outcome timeframe

Delivery, and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery

Results posted on

2022-06-14

Participant Flow

Participant milestones

Participant milestones
Measure
Divergent Abutment
Divergent Transition Profile Divergent Transition Profile: An Atlantis abutment is delivered with a linear transition profile
Concave Abutment
Concave Transition Profile Concave Transition Profile: An Atlantis abutment is delivered with a concave transition profile.
Overall Study
STARTED
29
32
Overall Study
COMPLETED
25
29
Overall Study
NOT COMPLETED
4
3

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Concave
n=32 Participants
Participants were missing a single-rooted tooth on the upper jaw and were randomly-assigned to receive a concave-shaped implant abutment.
Divergent
n=29 Participants
Participants were missing a single-rooted tooth on the upper jaw and were randomly assigned to receive a divergent-shaped implant abutment.
Total
n=61 Participants
Total of all reporting groups
Age, Categorical
<=18 years
0 Participants
n=32 Participants
0 Participants
n=29 Participants
0 Participants
n=61 Participants
Age, Categorical
Between 18 and 65 years
26 Participants
n=32 Participants
26 Participants
n=29 Participants
52 Participants
n=61 Participants
Age, Categorical
>=65 years
6 Participants
n=32 Participants
3 Participants
n=29 Participants
9 Participants
n=61 Participants
Sex: Female, Male
Female
19 Participants
n=32 Participants
10 Participants
n=29 Participants
29 Participants
n=61 Participants
Sex: Female, Male
Male
13 Participants
n=32 Participants
19 Participants
n=29 Participants
32 Participants
n=61 Participants
Race and Ethnicity Not Collected
0 Participants
Race and Ethnicity were not collected from any participant.

PRIMARY outcome

Timeframe: Delivery, and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery

Determine if there is a difference in soft tissue peri-implant zenith changes (in millimeters) for the concave/divergent abutment sites, specifically between at delivery and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery. This measurement is taken using a standardized stereotactic digital photography system that allows for increased measurement accuracy and precision, specifically with the Canfield Dental Camera, Canfield Imaging Systems.

Outcome measures

Outcome measures
Measure
Divergent Abutment
n=25 Participants
Divergent Transition Profile Divergent Transition Profile: An Atlantis abutment is delivered with a linear transition profile
Concave Abutment
n=29 Participants
Concave Transition Profile Concave Transition Profile: An Atlantis abutment is delivered with a concave transition profile.
Peri-Implant Mucosal Zenith Distance (in Millimeters) at the Concave/Divergent Abutment Sites
Delivery
9.860 millimeters
Standard Deviation 1.148
9.770 millimeters
Standard Deviation 1.146
Peri-Implant Mucosal Zenith Distance (in Millimeters) at the Concave/Divergent Abutment Sites
1 Month After Delivery
9.684 millimeters
Standard Deviation 1.203
9.618 millimeters
Standard Deviation 1.160
Peri-Implant Mucosal Zenith Distance (in Millimeters) at the Concave/Divergent Abutment Sites
3 Months after Delivery
9.674 millimeters
Standard Deviation 1.231
9.610 millimeters
Standard Deviation 1.174
Peri-Implant Mucosal Zenith Distance (in Millimeters) at the Concave/Divergent Abutment Sites
6 Months after Delivery
9.652 millimeters
Standard Deviation 1.166
9.599 millimeters
Standard Deviation 1.160
Peri-Implant Mucosal Zenith Distance (in Millimeters) at the Concave/Divergent Abutment Sites
12 Months after Delivery
9.622 millimeters
Standard Deviation 1.258
9.596 millimeters
Standard Deviation 1.167

SECONDARY outcome

Timeframe: Baseline and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery

Population: The reason why the overall number of participants analyzed differs from the data in the rows is due to some participants being lost to follow-up.

Determine if there is a difference in submarginal buccal-lingual soft tissue thickness in the peri-implant transition zone relative to a fixed reference point, specifically at baseline and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery. This measurement is taken using a standardized stereotactic digital photography system that allows for increased measurement accuracy and precision, specifically with the Canfield Dental Camera, Canfield Imaging Systems.

Outcome measures

Outcome measures
Measure
Divergent Abutment
n=27 Participants
Divergent Transition Profile Divergent Transition Profile: An Atlantis abutment is delivered with a linear transition profile
Concave Abutment
n=31 Participants
Concave Transition Profile Concave Transition Profile: An Atlantis abutment is delivered with a concave transition profile.
Submarginal Buccal-lingual Thickness (Millimeters) in the Peri-implant Transition Zone Relative to a Fixed Reference Point After Prosthesis Delivery
Baseline
2.722 millimeters
Standard Deviation 1.1294
2.814 millimeters
Standard Deviation 1.1291
Submarginal Buccal-lingual Thickness (Millimeters) in the Peri-implant Transition Zone Relative to a Fixed Reference Point After Prosthesis Delivery
1 month after delivery
2.667 millimeters
Standard Deviation 0.6202
2.597 millimeters
Standard Deviation 0.6248
Submarginal Buccal-lingual Thickness (Millimeters) in the Peri-implant Transition Zone Relative to a Fixed Reference Point After Prosthesis Delivery
3 months after delivery
2.840 millimeters
Standard Deviation 0.7176
2.468 millimeters
Standard Deviation 0.5764
Submarginal Buccal-lingual Thickness (Millimeters) in the Peri-implant Transition Zone Relative to a Fixed Reference Point After Prosthesis Delivery
6 months after delivery
2.920 millimeters
Standard Deviation 0.6403
2.517 millimeters
Standard Deviation 0.5796
Submarginal Buccal-lingual Thickness (Millimeters) in the Peri-implant Transition Zone Relative to a Fixed Reference Point After Prosthesis Delivery
12 months after delivery
2.740 millimeters
Standard Deviation 0.7654
2.500 millimeters
Standard Deviation 0.5000

SECONDARY outcome

Timeframe: Baseline and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery

Population: The reason why the number analyzed in one or more rows differs from the overall number analyzed is that some subjects were lost to follow-up.

Determine if there is a difference in Keratinized Mucosa Width (millimeters) in the apico-coronal direction at the midfacial aspect of the implant site, specifically at baseline and 1, 3, 6, and 12 months after Atlantis Abutment and Restoration Delivery. This measurement is taken using a standardized stereotactic digital photography system that allows for increased measurement accuracy and precision, specifically with the Canfield Dental Camera, Canfield Imaging Systems.

Outcome measures

Outcome measures
Measure
Divergent Abutment
n=27 Participants
Divergent Transition Profile Divergent Transition Profile: An Atlantis abutment is delivered with a linear transition profile
Concave Abutment
n=31 Participants
Concave Transition Profile Concave Transition Profile: An Atlantis abutment is delivered with a concave transition profile.
Keratinized Mucosa Width (Millimeters) at the Midfacial Aspect of the Implant Site.
Baseline
2.704 millimeters
Standard Deviation 1.1373
3.307 millimeters
Standard Deviation 1.8425
Keratinized Mucosa Width (Millimeters) at the Midfacial Aspect of the Implant Site.
1 month after delivery
3.407 millimeters
Standard Deviation 1.1522
3.936 millimeters
Standard Deviation 1.7212
Keratinized Mucosa Width (Millimeters) at the Midfacial Aspect of the Implant Site.
3 months after delivery
3.620 millimeters
Standard Deviation 0.8930
4.177 millimeters
Standard Deviation 1.6711
Keratinized Mucosa Width (Millimeters) at the Midfacial Aspect of the Implant Site.
6 months after delivery
3.478 millimeters
Standard Deviation 0.9946
4.067 millimeters
Standard Deviation 1.6439
Keratinized Mucosa Width (Millimeters) at the Midfacial Aspect of the Implant Site.
12 months after delivery
3.560 millimeters
Standard Deviation 1.0832
4.035 millimeters
Standard Deviation 1.8609

Adverse Events

Divergent Abutment

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Concave Abutment

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information