Trial Outcomes & Findings for Comparison of Different Intermittent Pneumatic Compression Devices for Deep Vein Thrombosis (NCT NCT01779648)

NCT ID: NCT01779648

Last Updated: 2013-05-01

Results Overview

Computed tomographic angiography were performed on 4th postoperative days to detect deep vein thrombosis and evaluate its extent and location.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

54 participants

Primary outcome timeframe

On 4th postoperative days after total knee replacement arthroplasty

Results posted on

2013-05-01

Participant Flow

The recruitment started in March, 2012 and ended in January, 2013. A total 57 participants were recruited and tested for enrollment after admission to the hospital.

Two of them were excluded prior to group assignment because of the detection of a lung cancer and a deep vein thrombosis, respectively.

Participant milestones

Participant milestones
Measure
Group SF
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression Simultaneous compression +Fixed refill time:
Group AA
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression Alternate compression+Adjusted refill time
Overall Study
STARTED
28
27
Overall Study
COMPLETED
27
27
Overall Study
NOT COMPLETED
1
0

Reasons for withdrawal

Reasons for withdrawal
Measure
Group SF
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression Simultaneous compression +Fixed refill time:
Group AA
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression Alternate compression+Adjusted refill time
Overall Study
Protocol Violation
1
0

Baseline Characteristics

Comparison of Different Intermittent Pneumatic Compression Devices for Deep Vein Thrombosis

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Group SF
n=28 Participants
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 Participants
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Total
n=55 Participants
Total of all reporting groups
Age, Categorical
<=18 years
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
8 Participants
n=5 Participants
1 Participants
n=7 Participants
9 Participants
n=5 Participants
Age, Categorical
>=65 years
20 Participants
n=5 Participants
26 Participants
n=7 Participants
46 Participants
n=5 Participants
Age Continuous
68.0 years
STANDARD_DEVIATION 8.1 • n=5 Participants
72.3 years
STANDARD_DEVIATION 5.9 • n=7 Participants
70.1 years
STANDARD_DEVIATION 7.4 • n=5 Participants
Sex: Female, Male
Female
26 Participants
n=5 Participants
24 Participants
n=7 Participants
50 Participants
n=5 Participants
Sex: Female, Male
Male
2 Participants
n=5 Participants
3 Participants
n=7 Participants
5 Participants
n=5 Participants
Region of Enrollment
Korea, Republic of
28 participants
n=5 Participants
27 participants
n=7 Participants
55 participants
n=5 Participants
Body Mass Index
Female
27.1 kg/m2
STANDARD_DEVIATION 5.2 • n=5 Participants
26.3 kg/m2
STANDARD_DEVIATION 4.4 • n=7 Participants
26.7 kg/m2
STANDARD_DEVIATION 4.8 • n=5 Participants
Body Mass Index
Male
26.5 kg/m2
STANDARD_DEVIATION 4.6 • n=5 Participants
28.0 kg/m2
STANDARD_DEVIATION 1.6 • n=7 Participants
27.4 kg/m2
STANDARD_DEVIATION 2.7 • n=5 Participants

PRIMARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Population: One participant of Group SF dropped out of the analysis due to the device error; air leakage in the closed circuit system.

Computed tomographic angiography were performed on 4th postoperative days to detect deep vein thrombosis and evaluate its extent and location.

Outcome measures

Outcome measures
Measure
Group SF
n=27 Participants
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 Participants
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Rate of Deep Vein Thrombosis
Deep vein thrombosis
14 participants
15 participants
Rate of Deep Vein Thrombosis
ipsilateral development
9 participants
12 participants
Rate of Deep Vein Thrombosis
contralateral development
1 participants
1 participants
Rate of Deep Vein Thrombosis
bilateral development
4 participants
2 participants
Rate of Deep Vein Thrombosis
distal DVT
13 participants
14 participants
Rate of Deep Vein Thrombosis
proximal DVT
1 participants
1 participants
Rate of Deep Vein Thrombosis
Symptomatic DVT
0 participants
0 participants

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Doppler ultrasonography were performed to measure one of the venous hemodynamic parameters to be compared. A longitudinal scans of bilateral superficial femoral veins, just distal to the confluence of the profunda femoral veins, were performed. Baseline velocity, flow pattern, and augmented flow of 11 seconds (Simultaneous compression arm) or 12 seconds (Alternate compression arm) were recorded. Under fixed state of other ultrasound scan parameters, peak velocity (PV) was measured by determination of maximum point of the augmented waveform.

Outcome measures

Outcome measures
Measure
Group SF
n=27 Participants
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 Participants
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Peak Velocity
24.8 cm/sec
Standard Deviation 5.9
22.8 cm/sec
Standard Deviation 4.9

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Doppler ultrasonography were performed to measure one of the venous hemodynamic parameters to be compared. A longitudinal scans of bilateral superficial femoral veins, just distal to the confluence of the profunda femoral veins, were performed. Baseline velocity, flow pattern, and augmented flow of 11 seconds (Alternate compression arm) or 12 seconds (Simultaneous compression arm) were recorded. This is an automatically measured mean value of venous flow.

Outcome measures

Outcome measures
Measure
Group SF
n=27 Participants
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 Participants
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Mean Velocity
10.0 cm/sec
Standard Deviation 2.5
9.7 cm/sec
Standard Deviation 2.7

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Doppler ultrasonography were performed to measure one of the venous hemodynamic parameters to be compared. A longitudinal scans of bilateral superficial femoral veins, just distal to the confluence of the profunda femoral veins, were performed. Baseline velocity, flow pattern, and augmented flow of 11 seconds (Simultaneous compression arm) or 12 seconds (Alternate compression arm) were recorded. Peak volume flow (PVF) was automatically calculated with 1-second interval around the PV.

Outcome measures

Outcome measures
Measure
Group SF
n=27 Participants
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 Participants
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Peak Volume Flow
205.3 mL/min
Standard Deviation 76.5
176.4 mL/min
Standard Deviation 72.1

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Doppler ultrasonography were performed to measure one of the venous hemodynamic parameters to be compared. A longitudinal scans of bilateral superficial femoral veins, just distal to the confluence of the profunda femoral veins, were performed. Baseline velocity, flow pattern, and augmented flow of 11 seconds (Simultaneous compression arm) or 12 seconds (Alternate compression arm) were recorded. Total volume flow (TVF) was automatically calculated by the software.

Outcome measures

Outcome measures
Measure
Group SF
n=27 Participants
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 Participants
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Total Volume Flow
160.9 mL/min
Standard Deviation 58.1
144.2 mL/min
Standard Deviation 59.0

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Expelled volume was theoretically calculated value in order to figure out how much blood was squeezed by the compression for an hour; expelled total volume (ETV) = single cycle augmented TVF x cycling rate (cycles/hour).

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Expelled Total Volume
right leg
7214.0 mL/hour
Standard Deviation 3389.2
4342.0 mL/hour
Standard Deviation 2419.0
Expelled Total Volume
left leg
6102.8 mL/hour
Standard Deviation 3957.6
3334.5 mL/hour
Standard Deviation 1390.5

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Expelled volume was theoretically calculated value in order to figure out how much blood was squeezed by the compression for an hour; expelled peak volume (EPV) = single cycle augmented PVF x cycling rate (cycles/hour).

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Expelled Peak Volume
right leg
999.8 mL/hour
Standard Deviation 344.3
633.1 mL/hour
Standard Deviation 321.4
Expelled Peak Volume
left leg
904.0 mL/hour
Standard Deviation 454.2
525.5 mL/hour
Standard Deviation 196.2

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Enhanced peak velocity by application of intermittent pneumatic compression

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Augmented PV
right
62.8 cm/sec
Standard Deviation 17.8
56.2 cm/sec
Standard Deviation 19.5
Augmented PV
left
57.1 cm/sec
Standard Deviation 20.2
58.5 cm/sec
Standard Deviation 18.8

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Enhanced mean velocity by application of pneumatic compression

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Augmented MV
right leg
20.4 cm/sec
Standard Deviation 9.6
18.2 cm/sec
Standard Deviation 4.7
Augmented MV
left leg
33.1 cm/sec
Standard Deviation 6.1
18.3 cm/sec
Standard Deviation 6.1

SECONDARY outcome

Timeframe: On 4th postoperative days after total knee replacement arthroplasty

Enhanced peak volume flow by application of pneumatic compression

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Augmented PVF
right leg
666.5 mL/min
Standard Deviation 229.5
514.6 mL/min
Standard Deviation 465.0
Augmented PVF
left leg
602.7 mL/min
Standard Deviation 302.8
465.0 mL/min
Standard Deviation 186.6

SECONDARY outcome

Timeframe: on 4th postoperative day after total knee replacement arthroplasty

Enhanced total volume flow by application of pneumatic compression

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Augmented TVF
right leg
400.7 mL/min
Standard Deviation 188.2
324.2 mL/min
Standard Deviation 150.5
Augmented TVF
left leg
339.0 mL/min
Standard Deviation 219.8
271.2 mL/min
Standard Deviation 135.8

SECONDARY outcome

Timeframe: on 4th postoperative day after total knee replacement arthroplasty

Number of cuff inflation-deflation cycle during an hour. In group SF, the cycling rate is fixed as 90 cycles/hour, but in group AA, it is variable according to the individual venous refill time.

Outcome measures

Outcome measures
Measure
Group SF
n=54 limbs
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=54 limbs
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Cycling Rate
90 cycles/hour
Standard Deviation 0
78.9 cycles/hour
Standard Deviation 20.4

Adverse Events

Group SF

Serious events: 0 serious events
Other events: 6 other events
Deaths: 0 deaths

Group AA

Serious events: 0 serious events
Other events: 5 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Other adverse events
Measure
Group SF
n=27 participants at risk
Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression simultaneous compression :
Group AA
n=27 participants at risk
alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression alternate compression :
Musculoskeletal and connective tissue disorders
operative wound oozing
3.7%
1/27
3.7%
1/27
Musculoskeletal and connective tissue disorders
wound pain aggravation
18.5%
5/27
14.8%
4/27

Additional Information

Principal Investigator

SMG-SNU Boramae Medical Center

Phone: +82-10-9988-2691

Results disclosure agreements

  • Principal investigator is a sponsor employee