Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
215 participants
INTERVENTIONAL
2012-10-31
2014-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Efficacy of the CRE8 Sirolimus-Eluting Stent for the Treatment of De Novo Coronary Artery Lesions
NCT02360709
Safety and Efficacy of the CRE8 Stent for the Treatment of De Novo Coronary Artery Lesions
NCT02360423
Post-Market Registry to Evaluate the Safety and Efficacy of the The SUPRAFLEX CRUZ™ Sirolimus Eluting Coronary Stent System in the Treatment of an Octo- and Nonagenerian All-Comer Patient Cohort With Coronary Artery Disease - the Cruz Senior Study
NCT04612179
Evaluation of Sirolimus-Eluting, Heparin-Coated CoCr Stent in the Treatment of de Novo Coronary Artery Lesions in Small Vessels(EVOLUTION)
NCT00233779
Sirolimus-Eluting Stent vs. Intravascular Brachytherapy in In-Stent Restenotic Coronary Artery Lesions(SISR)
NCT00231257
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The clinical need thus exists for enhanced stent designs which offer improved safety and efficacy profiles compared to the earlier stent platforms.
new technologies have been developed which have led to the creation of devices with delivery systems based on the use of more biocompatible or bioabsorbable polymers and cytostatic drugs similar to sirolimus. The clinical data obtained with this second generation have demonstrated, in all devices tested, no less efficacy than first-generation DES, and a better safety profile, although not statistically significant.Concerning the most widely used second generation DES,after a small first-in-man trial, its safety and efficacy was further studied in larger randomized trials on patients with non-complex lesions in which EES was compared to PES, proving its angiographic superiority and clinical non-inferiority. A step forward, in assessing the clinically significant differences among different DES, was done with a new randomized trial comparing EES versus PES, powered for testing superiority in clinical outcomes and of sufficient magnitude to provide data on patient subgroups, particularly patients with diabetes. At present, a third-generation of DES, developed to minimize the possible side effects related to the presence of the polymer, is being evaluated in humans. To avoid the presence of the polymer on the surface of the device, different platforms are being evaluated: those with a porous surface onto which the pure drug is placed and those with holes closed towards the intraluminal part by a bioabsorbable polymer, onto which the drug is loaded. A third option to avoid the need of polymers has been used in the new CRE8 DES, featuring a polymer free platform with abluminal reservoirs to release the Amphilimus formulation. This device has been tested against Taxus Liberté in a randomized clinical trial, to assess the non-inferiority angiographic efficacy results. The 6month angiographic analysis, demonstrates that the primary study endpoint has been achieved, showing that CRE8 was not inferior to Taxus Liberté in terms of efficacy performances.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
CR8
a drug eluting coronary device, made of Cobalt-Chromium alloy and integrally coated with i-Carbofilm™, loaded with formulated Sirolimus
CR8 a drug eluting coronary stent
a drug eluting coronary device, made of Cobalt-Chromium alloy and integrally coated with i-Carbofilm™, loaded with formulated Sirolimus
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CR8 a drug eluting coronary stent
a drug eluting coronary device, made of Cobalt-Chromium alloy and integrally coated with i-Carbofilm™, loaded with formulated Sirolimus
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients with symptoms of stable angina or documented silent ischemia
* Patient with coronary artery disease ranging between 0 and 22 according to the Syntax score
* Patients with acute coronary syndrome, including unstable angina, NSTEMI and STEMI
* Patient is eligible for percutaneous coronary intervention and is an acceptable candidate for surgical revascularization
* Left ventricular ejection fraction \> 30%;
* Target de-novo lesions with diameter stenosis \> 50% (including total occlusion)
* Target lesion located in a target vessel with a diameter ranging from 2.5 to 4.0 mm;
* patient has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Ethical Committee of the respective clinical site.
Exclusion Criteria
* Known allergies to antiplatelets, anticoagulants, contrast media, sirolimus or cobalt chromium;
* Acute or chronic renal dysfunction (defined as creatinine greater than 2.5 mg/dl or on dialysis);
* Thrombocytopenia (platelet count less than 100,000/mm³) or hypercoagulable disorder;
* Known significant gastro-intestinal or urinary bleeding within the past 6 months;
* Patient refusing blood transfusion;
* Patient currently under immunosuppressant therapy;
* Patient with planned surgery within 6 months from the index procedure unless dual antiplatelet therapy is maintained throughout the peri-surgical period;
* Co-morbidities that could interfere with completion of study procedures, or life expectancy less than 1 year;
* Participating in another investigational drug or device trial that has not completed the primary endpoint or would interfere with the endpoints of this study;
* Patient underwent target vessel revascularization, with a DES, within 3 months prior to the index procedure;
* Target lesion is located or supplied by an arterial or venous bypass graft
18 Years
99 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Tel-Aviv Sourasky Medical Center
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
michal roll
Prof. Shmuel Banai
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Shmuel Banai, Prof
Role: PRINCIPAL_INVESTIGATOR
Tel Aviv Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Tel Aviv Sourasky Medical Center
Tel Aviv, , Israel
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Create
Identifier Type: -
Identifier Source: org_study_id