Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization

NCT ID: NCT01681381

Last Updated: 2013-02-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

2790 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-09-30

Study Completion Date

2018-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a prospective, multi-center, open label, randomized study to evaluate the efficacy and safety of The TIVOLI Biodegradable polymer Rapamycin-Eluting Stent comparing with The FIREBIRD2™ Rapamycin-eluting Stent (DES) for Treatment Coronary Revascularization.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Ischemic Heart Disease Myocardial Ischemia Coronary Artery Lesions,Primary Coronary Disease Acute Coronary Syndrome Furcation Lesion of Coronary Artery

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Firebird2® DES

Device:Firebird2® DES The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length.

Group Type ACTIVE_COMPARATOR

Tivoli® DES

Intervention Type DEVICE

Device:Tivoli® DES The Tivoli® DES drug eluting stent(Tivoli® DES) is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug releasing in 1 week and approximately 80% releasing in 28 days. The polymer may be degraded in 3 to 6 months in human body. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 10、15、18、21、25、30、35 mm and diameters of 2.5、2.75、3.0、3.5、4.0 mm.

Firebird2® DES

Intervention Type DEVICE

The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug elutes in 1 week and approximately 90% elutes in 1 month. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 13, 18, 23, 29, 33 mm and diameters of 2.25, 2.5, 2.75, 3.0, 3.5, 4.0 mm.

Tivoli® DES

Device:Tivoli® DES The Tivoli® DES is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length.

Group Type EXPERIMENTAL

Tivoli® DES

Intervention Type DEVICE

Device:Tivoli® DES The Tivoli® DES drug eluting stent(Tivoli® DES) is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug releasing in 1 week and approximately 80% releasing in 28 days. The polymer may be degraded in 3 to 6 months in human body. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 10、15、18、21、25、30、35 mm and diameters of 2.5、2.75、3.0、3.5、4.0 mm.

Firebird2® DES

Intervention Type DEVICE

The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug elutes in 1 week and approximately 90% elutes in 1 month. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 13, 18, 23, 29, 33 mm and diameters of 2.25, 2.5, 2.75, 3.0, 3.5, 4.0 mm.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tivoli® DES

Device:Tivoli® DES The Tivoli® DES drug eluting stent(Tivoli® DES) is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug releasing in 1 week and approximately 80% releasing in 28 days. The polymer may be degraded in 3 to 6 months in human body. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 10、15、18、21、25、30、35 mm and diameters of 2.5、2.75、3.0、3.5、4.0 mm.

Intervention Type DEVICE

Firebird2® DES

The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug elutes in 1 week and approximately 90% elutes in 1 month. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 13, 18, 23, 29, 33 mm and diameters of 2.25, 2.5, 2.75, 3.0, 3.5, 4.0 mm.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* • The patient must be ≥18 of age;

* Symptomatic ischemic heart disease and/or objective evidence of myocardial ischemia including chronic stable coronary artery disease, or acute coronary syndrome including non-ST-elevation and ST-elevation myocardial infarction;
* Acceptable candidate for CABG;
* The patient is willing to comply with specified follow-up evaluations;4.Patients who agree to accept the follow-up visits.
* Patients can understand the study objectives psychologically and linguistically and show the sufficient compliance to the study protocol. Patients present acceptance of the risks and benefits described in the informed consent form.


* At least one lesion with a diameter stenosis \>70% or more suitable for coronary stent implantation in a vessel with a reference diameter ranging from 2.5 mm to 4.0 mm;
* Patients with multi-lesion or multi-vessel coronary disease, must have successful treatment (\<30% diameter stenosis visual estimate) of the first treated lesion prior to treatment of other lesions at the same brand of stent. Staged (planned) procedures must be performed within 30 days of the index procedure.

Exclusion Criteria

* Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure.
* Patient has a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated or in which patient will not be able to comply with dual antiplatelet therapy for at least 1 year;
* Patient has other medical illness (e.g., cancer, known malignancy, congestive heart failure, organ transplant recipient or candidate) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than 1 year);
* Left ventricular function \<40%;
* Cardiogenic shock or hemodynamic compromise requiring pressors and/or inotropes or mechanical support;
* Patient has a known hypersensitivity or contraindication to aspirin, heparin, clopidogrel/ticlopidine, stainless steel alloy, cobalt chromium, Rapamycinry , styrene-butylenes-styrene or poly-lactic acid (PLA) polymer, and/or contrast sensitivity that cannot be adequately pre-medicated;
* Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study;
* Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up.
* Existing impairment in liver and kidney.
* Extremely tortuous and/or calcification lesions.


• Two or more chronic total occlusions in the proximal half of the epicardial coronary artery which cannot be recannalized.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Essen Technology (Beijing) Co., Ltd.

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Han Yaling, Prof.

Role: PRINCIPAL_INVESTIGATOR

The General Hospital of Shenyang Military Region

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

The General Hospital of Shenyang Military Region

Shenyang, Liaoning, China

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

China

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Han Yaling, Prof.

Role: primary

(86-024) 28851120

References

Explore related publications, articles, or registry entries linked to this study.

Han Y, Xu B, Xu K, Guan C, Jing Q, Zheng Q, Li X, Zhao X, Wang H, Zhao X, Li X, Yu P, Zang H, Wang Z, Cao X, Zhang J, Pang W, Li J, Yang Y, Dangas GD. Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial. Circ Cardiovasc Interv. 2016 Feb;9(2):e003145. doi: 10.1161/CIRCINTERVENTIONS.115.003145.

Reference Type DERIVED
PMID: 26858080 (View on PubMed)

Han Y, Xu B, Jing Q, Lu S, Yang L, Xu K, Li Y, Li J, Guan C, Kirtane AJ, Yang Y; I-LOVE-IT 2 Investigators. A randomized comparison of novel biodegradable polymer- and durable polymer-coated cobalt-chromium sirolimus-eluting stents. JACC Cardiovasc Interv. 2014 Dec;7(12):1352-60. doi: 10.1016/j.jcin.2014.09.001. Epub 2014 Nov 12.

Reference Type DERIVED
PMID: 25440887 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

I-LOVE-IT2

Identifier Type: -

Identifier Source: org_study_id

More Related Trials