Trial Outcomes & Findings for Endoscopic Evaluation of Late Rectal Injury Following CyberKnife Radiosurgery for Prostate Cancer (NCT NCT01618838)
NCT ID: NCT01618838
Last Updated: 2018-08-22
Results Overview
Telangiectasia is the primary outcome since it is a measure of tissue fibrosis (primary source of proctitis) and is a well-defined and measurable outcome. No patients had outcome before the trial was terminated.
TERMINATED
NA
4 participants
Planned for 7 years, collected up to 23 months
2018-08-22
Participant Flow
Participant milestones
| Measure |
CyberKnife Radiosurgery, Colonoscopy
CyberKnife radiosurgery for prostate cancer; bowel toxicity will be evaluated at 2 years by colonoscopy (lower endoscopy).
CyberKnife radiosurgery: Treatment Planning:
Inverse planning using the CyberKnife planning system will be employed. The treatment plan used for each treatment will be based on an analysis of the volumetric dose including dose-volume histogram (DVH) analyses of the PTV and critical normal structures. The homogeneous CT model shall be used. Number of paths and beams used for each patient will vary and will be determined by the selected individual treatment plan. To reduce overall treatment time and total monitor units, 150-200 non-zero beams are recommended. No more than 250 beams shall be employed. Tuning structures shall be employed to minimize conformality index (CI) and new conformality index (nCI), preferably yielding values less than 1.20 and 1.25, respectively.
|
|---|---|
|
Overall Study
STARTED
|
4
|
|
Overall Study
COMPLETED
|
0
|
|
Overall Study
NOT COMPLETED
|
4
|
Reasons for withdrawal
| Measure |
CyberKnife Radiosurgery, Colonoscopy
CyberKnife radiosurgery for prostate cancer; bowel toxicity will be evaluated at 2 years by colonoscopy (lower endoscopy).
CyberKnife radiosurgery: Treatment Planning:
Inverse planning using the CyberKnife planning system will be employed. The treatment plan used for each treatment will be based on an analysis of the volumetric dose including dose-volume histogram (DVH) analyses of the PTV and critical normal structures. The homogeneous CT model shall be used. Number of paths and beams used for each patient will vary and will be determined by the selected individual treatment plan. To reduce overall treatment time and total monitor units, 150-200 non-zero beams are recommended. No more than 250 beams shall be employed. Tuning structures shall be employed to minimize conformality index (CI) and new conformality index (nCI), preferably yielding values less than 1.20 and 1.25, respectively.
|
|---|---|
|
Overall Study
slow accrual, trial closed prematurely.
|
4
|
Baseline Characteristics
Endoscopic Evaluation of Late Rectal Injury Following CyberKnife Radiosurgery for Prostate Cancer
Baseline characteristics by cohort
| Measure |
CyberKnife Radiosurgery, Colonoscopy
n=4 Participants
CyberKnife radiosurgery for prostate cancer; bowel toxicity will be evaluated at 2 years by colonoscopy (lower endoscopy).
CyberKnife radiosurgery: Treatment Planning:
Inverse planning using the CyberKnife planning system will be employed. The treatment plan used for each treatment will be based on an analysis of the volumetric dose including dose-volume histogram (DVH) analyses of the PTV and critical normal structures. The homogeneous CT model shall be used. Number of paths and beams used for each patient will vary and will be determined by the selected individual treatment plan. To reduce overall treatment time and total monitor units, 150-200 non-zero beams are recommended. No more than 250 beams shall be employed. Tuning structures shall be employed to minimize conformality index (CI) and new conformality index (nCI), preferably yielding values less than 1.20 and 1.25, respectively.
|
|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=5 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
0 Participants
n=5 Participants
|
|
Age, Categorical
>=65 years
|
4 Participants
n=5 Participants
|
|
Age, Continuous
|
75.5 years
n=5 Participants
|
|
Sex: Female, Male
Female
|
0 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
4 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
1 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
2 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
1 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
Region of Enrollment
United States
|
4 participants
n=5 Participants
|
PRIMARY outcome
Timeframe: Planned for 7 years, collected up to 23 monthsTelangiectasia is the primary outcome since it is a measure of tissue fibrosis (primary source of proctitis) and is a well-defined and measurable outcome. No patients had outcome before the trial was terminated.
Outcome measures
| Measure |
CyberKnife Radiosurgery, Colonoscopy
n=4 Participants
CyberKnife radiosurgery for prostate cancer; bowel toxicity will be evaluated at 2 years by colonoscopy (lower endoscopy).
CyberKnife radiosurgery: Treatment Planning:
Inverse planning using the CyberKnife planning system will be employed. The treatment plan used for each treatment will be based on an analysis of the volumetric dose including dose-volume histogram (DVH) analyses of the PTV and critical normal structures. The homogeneous CT model shall be used. Number of paths and beams used for each patient will vary and will be determined by the selected individual treatment plan. To reduce overall treatment time and total monitor units, 150-200 non-zero beams are recommended. No more than 250 beams shall be employed. Tuning structures shall be employed to minimize conformality index (CI) and new conformality index (nCI), preferably yielding values less than 1.20 and 1.25, respectively.
|
|---|---|
|
Proportion of Patients With Endoscopically Detectable-telangiectasia (VRS Grade 1 or Higher).
|
0 Participants
|
SECONDARY outcome
Timeframe: Planned for 7 years, collected up to 23 monthsPopulation: No patients had outcome before the trial was terminated.
Outcome measures
| Measure |
CyberKnife Radiosurgery, Colonoscopy
n=4 Participants
CyberKnife radiosurgery for prostate cancer; bowel toxicity will be evaluated at 2 years by colonoscopy (lower endoscopy).
CyberKnife radiosurgery: Treatment Planning:
Inverse planning using the CyberKnife planning system will be employed. The treatment plan used for each treatment will be based on an analysis of the volumetric dose including dose-volume histogram (DVH) analyses of the PTV and critical normal structures. The homogeneous CT model shall be used. Number of paths and beams used for each patient will vary and will be determined by the selected individual treatment plan. To reduce overall treatment time and total monitor units, 150-200 non-zero beams are recommended. No more than 250 beams shall be employed. Tuning structures shall be employed to minimize conformality index (CI) and new conformality index (nCI), preferably yielding values less than 1.20 and 1.25, respectively.
|
|---|---|
|
Proportion of Patients With Rectal Bleeding.
|
0 Participants
|
SECONDARY outcome
Timeframe: Planned for 7 years, collected up to 23 monthsProgression-free survival will be defined as the time in months from study entry until progression or death. Patients who are alive and free from progression on the date of closing follow-up will be censored on that date. Data table reports the number of participants who were alive without progression at the end of the study.
Outcome measures
| Measure |
CyberKnife Radiosurgery, Colonoscopy
n=4 Participants
CyberKnife radiosurgery for prostate cancer; bowel toxicity will be evaluated at 2 years by colonoscopy (lower endoscopy).
CyberKnife radiosurgery: Treatment Planning:
Inverse planning using the CyberKnife planning system will be employed. The treatment plan used for each treatment will be based on an analysis of the volumetric dose including dose-volume histogram (DVH) analyses of the PTV and critical normal structures. The homogeneous CT model shall be used. Number of paths and beams used for each patient will vary and will be determined by the selected individual treatment plan. To reduce overall treatment time and total monitor units, 150-200 non-zero beams are recommended. No more than 250 beams shall be employed. Tuning structures shall be employed to minimize conformality index (CI) and new conformality index (nCI), preferably yielding values less than 1.20 and 1.25, respectively.
|
|---|---|
|
Progression-free Survival
|
4 Participants
|
Adverse Events
CyberKnife Radiosurgery, Colonoscopy
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place