Prospective Study of the BioVentrix PliCath HF™ System for the Treatment of Ischemic Cardiomyopathy
NCT ID: NCT01568138
Last Updated: 2021-03-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
26 participants
INTERVENTIONAL
2010-08-31
2015-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Appropriate subjects will have akinetic or dyskinetic scar located in the antero-septal LV distribution. Use of this device replicates the geometric reconfiguration of the ventricle achieved through surgical Left Ventricular Reconstruction (LVR), but on a beating, unsupported heart, thereby creating the option of avoiding the use of cardiopulmonary bypass pump (CBP).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Efficacy Study of the BioVentrix PliCath HF System
NCT01568164
Clinical Trial of Ventiflow LP Supporting High-risk Percutaneous Coronary Intervention(PCI)
NCT06754839
Bio Refine for Functional Mitral Regurgitation - a Safety & Feasibility Study
NCT06583876
Identifying and Facilitating Ventricular Recovery on Mechanical Support
NCT00687856
Magenta Elevate™ Clinical Feasibility Study in Cardiogenic Shock
NCT07293923
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In view of the limitations of existing therapy, physicians have sought alternative treatments. In this regard, there has been longstanding interest in surgical reconstruction of the failing heart. The underlying premise has been to surgically reduce the size of the ventricular chamber by removing a portion of the ventricular wall to decrease chamber radius. A reduction of chamber radius reduces wall stress for a given pressure so that the remaining muscle is put into a more favorable mechanical state.
The BioVentrix PliCath HF System consists of implantable anchors, the delivery system, and accessories, which are sterile and biocompatible. These devices are used in the reconfiguration of the abnormal cardiac geometry that is causing dysfunction by excluding a portion of the left ventricular chamber.
The procedure is based on the premise that the beneficial effects of Left Ventricular Reconstruction (LVR) via radius and volume reduction, can be realized by excluding a portion of the scarred left ventricle wall circumference. The procedure is similar to a Dor procedure except that it utilizes a series of anchors in place of the Fontan stitch and patch to exclude infarcted tissue and reduce the size of the left ventricle chamber and the scarred left ventricle wall. Because the ventricle is not resected, it is possible to do the procedure without a cardiopulmonary bypass pump.
The validity of this concept has been documented. Geometric confirmation was initially accomplished in a bench model, where radius was decreased by 24% and volume was diminished by 35% after exclusion of an antero-septal wall segment in dilated, explanted porcine hearts.
When using the PliCath System in accomplishing LV reconfiguration, the fundamental technical maneuver is placement of a hollow needle through a predetermined site in the anterior wall scar, across the LV chamber, and through a predetermined site in the scarred interventricular septum. Once achieved, a flexible guidewire is advanced through the needle and into the free right ventricular (RV) chamber. Once the wire is completely through the septum, a dilator enables passage of a 14Fr Introducer to traverse the needle route, allowing introduction of an internal, elongated anchor which can be oriented into appropriate alignment and matched with an external anchor of identical length and alignment. The anchors, which are placed in the RV and on the epicardium as a result of the original needle passage, can be brought toward each other until contact between the two walls is established and they are apposed along their lengths. The action is repeated (i.e., repeated needle sticks and anchor placement), along the long axis of the LV until a linear portion of antero-lateral wall is in contact with a corresponding portion of the septum, excluding the entire intervening wall segment from the circumference of the chamber.
The device is designed to allow removal at any stage of deployment prior to removal of the "Leash" attached to the hinged, internal anchor.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PliCath HF System
To evaluate the safety and feasibility of the BioVentrix PliCath HF Epicardial Catheter-based Ventricular Reduction (ECVR) System for left ventricular (LV) volume reduction in heart failure (HF). The System utilizes anchors that are implanted into the scarred portion of the heart, rendering the ventricle smaller.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 15% ≥ LVEF ≤ 45%
* NYHA FC II-III
* 60 cc/m² ≥ LVESV/I ≤ 120 cc/m²
* Acontractile (akinetic and/or dyskinetic) scar located in the antero-septalapical region due to prior infarction as evidenced by an echocardiogram and/or an MRI
* Maintained standard medical management for at least 90 days, and at stable target (or maximum tolerated) dosages.
* Willing and competent to complete informed consent
* Viability of myocardium in regions remote from area of intended scar exclusion as evidenced by an echocardiogram and/or an MRI
* Agree to required follow-up visits
Exclusion Criteria
* Thrombus or intra-ventricular mass in left atrium or ventricle Cardiac Resynchronization Therapy (CRT) device placement within prior 60 days of enrollment
* Significant diastolic dysfunction, defined as a pseudonormal Doppler filling pattern with E/A ratio \> 2
* Thin walled, paradoxically moving septal scar that would preclude successful support of the anchor pairs as evidenced by an MRI
* Cardiac valve disease which, in the opinion of the investigator, will require surgery
* Mitral Regurgitation \> 1+
* Intolerance or unwillingness to take warfarin
* Functioning pacemaker leads in antero-apical RV which, in the opinion of the investigator, would interfere with anchor placement.
* Pulmonary Arterial Pressure \> 60 mm Hg
* Myocardial Infarction within prior 90 days enrollment
* Previous CVA or TIA which resulted, in the opinion of the investigator, in a significant residual neurological deficit
* Co-morbid disease process with life expectancy of less than one year
* Patients with lung, kidney and/or liver transplant
* Chronic renal failure with a serum creatinine \> 2 mg/dL
* Pregnant or planning to become pregnant during the study
* Enrolled in any concurrent study other than observational
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ohio State University
OTHER
Centro Diagnostico Italiano
UNKNOWN
Advance Research Associates
OTHER
BioVentrix
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Pauls Stradins Hospital
Riga, , Latvia
Santariskiu Klinikus
Vilnius, , Lithuania
Jagiellonian University Hospital
Krakow, , Poland
Bakoulev Institute
Moscow, , Russia
Countries
Review the countries where the study has at least one active or historical site.
Related Links
Access external resources that provide additional context or updates about the study.
Sponsor company web site
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20032-P
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.