Trial Outcomes & Findings for Proclear 1-D Multifocal Nondispensing Study (NCT NCT01526902)
NCT ID: NCT01526902
Last Updated: 2014-04-07
Results Overview
Tested with charts distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
COMPLETED
NA
49 participants
After 1 hour of lens wear
2014-04-07
Participant Flow
Recruitment was open between 06FEB2012 and 28FEB2012
The subjects who are current contact lens wearers should attend the first visit wearing their habitual lenses and having worn them that day for at least 2 hours prior to the visit.
Participant milestones
| Measure |
Omafilcon A (PC 1-D MF) / Lotrafilcon B (AIR OPTIX MF)
Subjects were randomly assigned into either the omafilcon A (PC 1-D) Multifocal with +0.75D over-correction in the non-dominant eye or the Air Optix Aqua (lotrafilcon B)Multifocal lenses as their initial pair. Lens Pair 1 were evaluated for fit, vision and comfort (1 hour after lens application). Following this evaluation and during this same visit, the subject then crossed-over into the alternative pair of study lenses. This second pair of lenses was also evaluated for fit, vision and comfort (1 hour after lens application).
|
Lotrafilcon B (AIR OPTIX MF) / Omafilcon A (PC 1-D MF)
Subjects were randomly assigned into either the omafilcon A (PC 1-D) Multifocal with +0.75D over-correction in the non-dominant eye or the Air Optix Aqua (lotrafilcon B)Multifocal lenses as their initial pair. Lens Pair 1 were evaluated for fit, vision and comfort (1 hour after lens application). Following this evaluation and during this same visit, the subject then crossed-over into the alternative pair of study lenses. This second pair of lenses was also evaluated for fit, vision and comfort (1 hour after lens application).
|
|---|---|---|
|
Overall Study
STARTED
|
25
|
24
|
|
Overall Study
COMPLETED
|
25
|
24
|
|
Overall Study
NOT COMPLETED
|
0
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Proclear 1-D Multifocal Nondispensing Study
Baseline characteristics by cohort
| Measure |
Overall Study Population
n=49 Participants
Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.
|
|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=93 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
49 Participants
n=93 Participants
|
|
Age, Categorical
>=65 years
|
0 Participants
n=93 Participants
|
|
Age, Continuous
|
53 years
STANDARD_DEVIATION 6 • n=93 Participants
|
|
Sex: Female, Male
Female
|
39 Participants
n=93 Participants
|
|
Sex: Female, Male
Male
|
10 Participants
n=93 Participants
|
|
Region of Enrollment
United States
|
49 participants
n=93 Participants
|
PRIMARY outcome
Timeframe: After 1 hour of lens wearPopulation: Per Protocol
Tested with charts distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
Outcome measures
| Measure |
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
|
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
|
|---|---|---|
|
Objective Vision Assessments: High Contrast Distance Visual Acuity
|
-0.09 logMAR units
Standard Deviation 0.08
|
-0.05 logMAR units
Standard Deviation 0.08
|
PRIMARY outcome
Timeframe: After 1 hour of lens wearPopulation: Per Protocol
Tested with charts at intermediate distance (100cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
Outcome measures
| Measure |
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
|
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
|
|---|---|---|
|
Objective Vision Assessments: High Contrast Intermediate Visual Acuity
|
-0.11 logMAR units
Standard Deviation 0.08
|
-0.10 logMAR units
Standard Deviation 0.09
|
PRIMARY outcome
Timeframe: After 1 hour of lens wearPopulation: Per Protocol
Tested with charts set at near point (40cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.
Outcome measures
| Measure |
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
|
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
|
|---|---|---|
|
Objective Vision Assessments: High Contrast Near Visual Acuity
|
0.08 logMAR units
Standard Deviation 0.14
|
0.05 logMAR units
Standard Deviation 0.12
|
SECONDARY outcome
Timeframe: After 1 hour of lens wearPopulation: Per Protocol
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
Outcome measures
| Measure |
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
|
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
|
|---|---|---|
|
Subjective Overall Vision: High Contrast Distance Visual Quality
|
87 units on a scale
Standard Deviation 16
|
88 units on a scale
Standard Deviation 11
|
SECONDARY outcome
Timeframe: After 1 hour of lens wearPopulation: Per Protocol
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
Outcome measures
| Measure |
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
|
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
|
|---|---|---|
|
Subjective Vision Assessments: High Contrast Intermediate Visual Quality
|
85 units on a scale
Standard Deviation 15
|
85 units on a scale
Standard Deviation 15
|
SECONDARY outcome
Timeframe: After 1 hour of lens wearPopulation: Per Protocol
Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.
Outcome measures
| Measure |
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
|
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
|
|---|---|---|
|
Subjective Vision Assessments: High Contrast Near Visual Quality
|
81 units on a scale
Standard Deviation 18
|
80 units on a scale
Standard Deviation 18
|
Adverse Events
Lotrafilcon B / Air Optix MF (CONTROL)
Omafilcon A / PC1DMF L2A (TEST)
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Pete Kollbaum, OD, PhD, FAAO, FBCLA, Principal Investigator
Indiana University
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place
Restriction type: GT60