Trial Outcomes & Findings for Proclear 1-D Multifocal Nondispensing Study (NCT NCT01526902)

NCT ID: NCT01526902

Last Updated: 2014-04-07

Results Overview

Tested with charts distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

49 participants

Primary outcome timeframe

After 1 hour of lens wear

Results posted on

2014-04-07

Participant Flow

Recruitment was open between 06FEB2012 and 28FEB2012

The subjects who are current contact lens wearers should attend the first visit wearing their habitual lenses and having worn them that day for at least 2 hours prior to the visit.

Participant milestones

Participant milestones
Measure
Omafilcon A (PC 1-D MF) / Lotrafilcon B (AIR OPTIX MF)
Subjects were randomly assigned into either the omafilcon A (PC 1-D) Multifocal with +0.75D over-correction in the non-dominant eye or the Air Optix Aqua (lotrafilcon B)Multifocal lenses as their initial pair. Lens Pair 1 were evaluated for fit, vision and comfort (1 hour after lens application). Following this evaluation and during this same visit, the subject then crossed-over into the alternative pair of study lenses. This second pair of lenses was also evaluated for fit, vision and comfort (1 hour after lens application).
Lotrafilcon B (AIR OPTIX MF) / Omafilcon A (PC 1-D MF)
Subjects were randomly assigned into either the omafilcon A (PC 1-D) Multifocal with +0.75D over-correction in the non-dominant eye or the Air Optix Aqua (lotrafilcon B)Multifocal lenses as their initial pair. Lens Pair 1 were evaluated for fit, vision and comfort (1 hour after lens application). Following this evaluation and during this same visit, the subject then crossed-over into the alternative pair of study lenses. This second pair of lenses was also evaluated for fit, vision and comfort (1 hour after lens application).
Overall Study
STARTED
25
24
Overall Study
COMPLETED
25
24
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Proclear 1-D Multifocal Nondispensing Study

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Overall Study Population
n=49 Participants
Subjects were randomly assigned into either the omafilcon A/PC 1-D MF lenses with +0.75D over-correction in the non-dominant eye or the lotrafilcon B/Air Optix MF lenses then crossed-over into the alternative pair of study lenses.
Age, Categorical
<=18 years
0 Participants
n=93 Participants
Age, Categorical
Between 18 and 65 years
49 Participants
n=93 Participants
Age, Categorical
>=65 years
0 Participants
n=93 Participants
Age, Continuous
53 years
STANDARD_DEVIATION 6 • n=93 Participants
Sex: Female, Male
Female
39 Participants
n=93 Participants
Sex: Female, Male
Male
10 Participants
n=93 Participants
Region of Enrollment
United States
49 participants
n=93 Participants

PRIMARY outcome

Timeframe: After 1 hour of lens wear

Population: Per Protocol

Tested with charts distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.

Outcome measures

Outcome measures
Measure
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
Objective Vision Assessments: High Contrast Distance Visual Acuity
-0.09 logMAR units
Standard Deviation 0.08
-0.05 logMAR units
Standard Deviation 0.08

PRIMARY outcome

Timeframe: After 1 hour of lens wear

Population: Per Protocol

Tested with charts at intermediate distance (100cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.

Outcome measures

Outcome measures
Measure
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
Objective Vision Assessments: High Contrast Intermediate Visual Acuity
-0.11 logMAR units
Standard Deviation 0.08
-0.10 logMAR units
Standard Deviation 0.09

PRIMARY outcome

Timeframe: After 1 hour of lens wear

Population: Per Protocol

Tested with charts set at near point (40cm)distant to the subject with both eyes together in normal lighting conditions. The unit of measure is logMAR units (logarithm of the minimum angle of resolution) A logMAR acuity of 0.0 equates to 20/20 Snellen acuity. Positive logMAR values indicate poorer vision and negative values denote better visual acuity than baseline 20/20 value.

Outcome measures

Outcome measures
Measure
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
Objective Vision Assessments: High Contrast Near Visual Acuity
0.08 logMAR units
Standard Deviation 0.14
0.05 logMAR units
Standard Deviation 0.12

SECONDARY outcome

Timeframe: After 1 hour of lens wear

Population: Per Protocol

Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.

Outcome measures

Outcome measures
Measure
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
Subjective Overall Vision: High Contrast Distance Visual Quality
87 units on a scale
Standard Deviation 16
88 units on a scale
Standard Deviation 11

SECONDARY outcome

Timeframe: After 1 hour of lens wear

Population: Per Protocol

Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.

Outcome measures

Outcome measures
Measure
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
Subjective Vision Assessments: High Contrast Intermediate Visual Quality
85 units on a scale
Standard Deviation 15
85 units on a scale
Standard Deviation 15

SECONDARY outcome

Timeframe: After 1 hour of lens wear

Population: Per Protocol

Subjects instructed to rate Vision quality at distance, intermediate and near vision (OU) using a 0-100 numerical scale where 0 = poor and 100 = excellent.

Outcome measures

Outcome measures
Measure
PC1DMF
n=49 Participants
(Test Lens) omafilcon A Proclear 1-D multifocal lens
Air Optix MF
n=49 Participants
(Control Lens) lotrafilcon B Air Optix Aqua Multifocal
Subjective Vision Assessments: High Contrast Near Visual Quality
81 units on a scale
Standard Deviation 18
80 units on a scale
Standard Deviation 18

Adverse Events

Lotrafilcon B / Air Optix MF (CONTROL)

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Omafilcon A / PC1DMF L2A (TEST)

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Pete Kollbaum, OD, PhD, FAAO, FBCLA, Principal Investigator

Indiana University

Phone: 812-856-0108

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place

Restriction type: GT60