High-frequency Oscillatory Ventilation (HFOV) in Preterm Infants With Severe Respiratory Distress Syndrome (RDS)
NCT ID: NCT01496508
Last Updated: 2011-12-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE2
360 participants
INTERVENTIONAL
2007-06-30
2011-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
HFOV
A SLE5000 infant ventilator was used as the high-frequency ventilator.HFOV setting were as follows: initial frequency was set between 11 and 15Hz; pressure amplitude of oscillation was initially adjusted to provide adequate chest wall movement and was subsequently titrated to maintain the PaCO2 between 40 and 55 mmHg.Extubation was considered when the patient's condition was stable for 12-24h, while adequate oxygenation could be maintained with an FIO2 \<0.3 and respiratory rate \<25/min.
mechanical ventilation (SLE 5000, Servo-i-Maquet)
Ventilation strategies for both groups were to emphasize lung recruitment and avoid atelectasis and over distention. The optimum lung volume was determined as expansion to 8 to 9.5 ribs for most infants, and 7 to 8 ribs for infants with air leak. HFOV setting were as follows: initial frequency was set between 11 and 15Hz; pressure amplitude of oscillation was initially adjusted to provide adequate chest wall movement and was subsequently titrated to maintain the PaCO2 between 40 and 55 mmHg; The initial mean airway pressure (MAP) was set at 8-10 cmH2O. MAP and FIO2 were set to maintain arterial oxygen saturation between 88 to 95%, an arterial pH of at least 7.25. Extubation was considered when MAP was ≤7 cmH2O and the pressure amplitude of oscillation reach 10 to 15 cmH2O.
CV
A Servo-i-Maquet will be used as the conventional mechanical ventilator. CV settings were: exhaled tidal volumes set at 5-6 mL/kg, initial peak inspiratory pressure (PIP) of 15-25 cmH2O; positive expiratory end pressure (PEEP) set to 4-6 cmH2O; inspiratory times of 0.25-0.40s; rates set to \<60/min. The weaning process was initiated when the following parameters were achieved: PIP \<18 cmH2O, PEEP \<4 cmH2O, and FIO2 \<0.4. Extubation was considered when the patient's condition was stable for 12-24h, while adequate oxygenation could be maintained with an FIO2 \<0.3 and respiratory rate \<25/min. All infants extubated onto nasal continuous positive airway pressure (Infant Flow, Electro Medical Equipment) and then weaned to a nasal cannula, and then to room air.
mechanical ventilation (SLE 5000, Servo-i-Maquet)
Ventilation strategies for both groups were to emphasize lung recruitment and avoid atelectasis and over distention. The optimum lung volume was determined as expansion to 8 to 9.5 ribs for most infants, and 7 to 8 ribs for infants with air leak. HFOV setting were as follows: initial frequency was set between 11 and 15Hz; pressure amplitude of oscillation was initially adjusted to provide adequate chest wall movement and was subsequently titrated to maintain the PaCO2 between 40 and 55 mmHg; The initial mean airway pressure (MAP) was set at 8-10 cmH2O. MAP and FIO2 were set to maintain arterial oxygen saturation between 88 to 95%, an arterial pH of at least 7.25. Extubation was considered when MAP was ≤7 cmH2O and the pressure amplitude of oscillation reach 10 to 15 cmH2O.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
mechanical ventilation (SLE 5000, Servo-i-Maquet)
Ventilation strategies for both groups were to emphasize lung recruitment and avoid atelectasis and over distention. The optimum lung volume was determined as expansion to 8 to 9.5 ribs for most infants, and 7 to 8 ribs for infants with air leak. HFOV setting were as follows: initial frequency was set between 11 and 15Hz; pressure amplitude of oscillation was initially adjusted to provide adequate chest wall movement and was subsequently titrated to maintain the PaCO2 between 40 and 55 mmHg; The initial mean airway pressure (MAP) was set at 8-10 cmH2O. MAP and FIO2 were set to maintain arterial oxygen saturation between 88 to 95%, an arterial pH of at least 7.25. Extubation was considered when MAP was ≤7 cmH2O and the pressure amplitude of oscillation reach 10 to 15 cmH2O.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Who developed RDS requiring mechanical ventilation
3. Presented a partial pressure of oxygen (PaO2): fraction of inspired oxygen (FIO2) ratio \<200
4. Radiograph criteria of severe RDS
Exclusion Criteria
2. Congenital abnormalities
3. Pneumothorax
4. Grade III-IV intracranial hemorrhage
24 Hours
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Zhengzhou Children's Hospital, China
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Changlian Zhu
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Hong Xiong, MD
Role: STUDY_DIRECTOR
Zhengzhou Children's Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Zhengzhou Children's Hospital
Zhengzhou, Henan, China
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Sun H, Cheng R, Kang W, Xiong H, Zhou C, Zhang Y, Wang X, Zhu C. High-frequency oscillatory ventilation versus synchronized intermittent mandatory ventilation plus pressure support in preterm infants with severe respiratory distress syndrome. Respir Care. 2014 Feb;59(2):159-69. doi: 10.4187/respcare.02382. Epub 2013 Jun 13.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ZZ-HFOV
Identifier Type: -
Identifier Source: org_study_id