COmplex BifuRcation Lesions: a Comparison Between the AXXESS Device and Culotte Stenting: an Optical Coherence Tomography (OCT) Study

NCT ID: NCT01486095

Last Updated: 2017-05-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

40 participants

Study Classification

INTERVENTIONAL

Study Start Date

2011-11-29

Study Completion Date

2017-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Treatment of bifurcation lesions with drug-eluting stents (DES) (especially when a double stent technique is used) is associated with a higher risk for stent thrombosis. Different factors may play a role in the higher risk for stent thrombosis in bifurcation lesions. Possible mechanisms are delayed endothelialisation due to the action of the drug, coating polymers, or overlapping stent segments, incomplete stent apposition at specific sites in the bifurcation lesion and higher thrombogenicity due to turbulent flow at the bifurcation site. In human pathological data, the RUTSS (ratio of uncovered to total stent struts) appears to be the most powerful predictor of stent thrombosis.

This prospective study will assess the differences in stent strut coverage and stent strut apposition after complex bifurcation lesion treatment with the dedicated AXXESS Biolimus A9-eluting bifurcation stent at the bifurcation site and additional Biomatrix Biolimus A9-eluting stents in the distal main vessel and the side branch versus treatment with the culotte technique using the Xience Prime everolimus-eluting stents.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

BACKGROUND: There is an ongoing controversy over the efficacy and safety of different bifurcation stenting techniques. Critical considerations are the rate of restenosis at the side branch ostium, and completeness of healing at sites of overlap of stent struts, which may affect the risk of stent thrombosis.

AIMS: To compare vessel healing at 9 months using OCT imaging for two different treatment techniques for treating bifurcation lesions. Quantitative assessment of OCT images will be used to assess re-endothelialisation and quality of strut apposition to the vessel wall.

METHODS: Patients with true bifurcation lesions with involvement of a significant side branch requiring a stent will be randomly assigned to one of two treatment strategies. Group A will comprise 20 patients which will be treated with the Axxess™ Drug Eluting Coronary Bifurcation Stent System (Biosensors Europe SA) where additional Biomatrix™ Drug Eluting Coronary Stent Systems (Biosensors Europe SA) are implanted into the distal main branch (MB) and the side branch (SB) as required. Group B will consist of 20 patients which will be treated with the culotte technique using Xience Prime everolimus-eluting stents (Abbott-Vascular, US). Kissing balloon dilatation using non-compliant balloons will complete the index procedure in all cases. At 9 months, control angiography for all patients (with QCA using dedicated software) and OCT (of both main vessel and side branch) will be performed.

ENROLMENT PLAN:

Start: Third quarter of 2011 Enrolment period: ± 12 months Clinical follow-up: 5 years Angiographic and OCT results expected third quarter of 2013

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

True Coronary Bifurcation Lesions

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

AXXESS + Biomatrix

After mandatory predilatation, a self-expanding, conically shaped nickel-titanium AXXESS biolimus A9-eluting stent is placed at the level of the carina. The device is available in 3.0 and 3.5 mm calibre and 11 and 14 mm length. Depending on the lesion anatomy, additional Biomatrix™ Drug Eluting Coronary Stent Systems are placed distally if necessary. The procedure is completed with kissing balloon postdilatation using non-compliant balloons sized to the reference vessel diameter of the distal branches. Before this kissing balloon inflation, consecutive high pressure inflations should be performed in both branches.

Group Type EXPERIMENTAL

AXXESS + Biomatrix Biolimus Eluting stent

Intervention Type DEVICE

NAP

Culotte technique: Xience V/Prime

The culotte technique consists of stenting one of both branches of the bifurcation lesion first, and after balloon dilatation of the stent meshes, stenting the uncovered branch through the first stent and leaving the main vessel covered with two overlapped stents. The procedure is terminated by kissing balloon dilatation of both branches using non-compliant balloons sized to the reference vessel diameter of the distal branches. Before this kissing balloon inflation, consecutive high pressure inflations should be performed in both branches.

Group Type ACTIVE_COMPARATOR

Culotte technique with Xience V or Xience Prime stents

Intervention Type DEVICE

NAP

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

AXXESS + Biomatrix Biolimus Eluting stent

NAP

Intervention Type DEVICE

Culotte technique with Xience V or Xience Prime stents

NAP

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Patient older than 18 years
2. The subject has stable or unstable angina pectoris, or a positive functional study for ischemia.
3. The subject is eligible for PCI, and is an acceptable candidate for coronary artery bypass surgery.
4. The subject is male, or if female, has no childbearing potential or has had a negative urine or serum pregnancy test within 7 days of the index procedure and has no intention to become pregnant within a year of the procedure.
5. The subject has signed the informed consent prior to the procedure, and agrees to comply with the follow up requirements.
6. Patients with a de novo and true coronary bifurcation lesion (Medina classification (1,1,1), (1,0,1) or (0,1,1)).
7. Coronary artery with proximal parent vessel reference diameter of 2.75 - 3.75 mm and a branch vessel diameter of ≥ 2.25 mm.
8. The lesion must be at least 50% diameter stenosis within either the MB or SB.
9. Regarding lesion length: lesion should be able to be covered by 2 Xience Prime stents in a Culotte technique, or by a combination of maximally 1 AXXESS and 2 Biomatrix™ Drug Eluting Coronary Stents.
10. The side branch ostium is located at least 12 mm from the left main coronary artery.
11. The angle between the sidebranch and the parent vessel is less than 70°.

Exclusion Criteria

1. Left ventricular ejection fraction of \< 30%
2. Impaired renal function (serum creatinine \> 2.0 mg/dl)
3. Previous and/or planned brachytherapy of target vessel
4. Lesion of the left main trunk \> 50%, unprotected
5. The target vessel contains intraluminal thrombus.
6. The target lesion shows angiographic evidence of moderate to severe calcification or tortuosity.
7. Known allergies to antiplatelet, anticoagulation therapy, contrast media, everolimus or biolimus, stainless steel, cobalt, chromium, nickel or titanium
8. Pregnant and/or breast-feeding females or females who intend to become pregnant (pregnancy test required)
9. Patients with a life expectancy of less than one year
10. Patient currently enrolled in other investigational device or drug trial
11. Patient not able or willing to adhere to follow-up visits
12. Patients who intend to have a major surgical intervention within 6 months of enrolment in the study.
13. Patients who previously participated in this study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Biosensors International

OTHER

Sponsor Role collaborator

Universitaire Ziekenhuizen KU Leuven

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Prof Dr Walter Desmet

Christophe Dubois, MD, PhD, Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Christophe L Dubois, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Universitaire Ziekenhuizen KU Leuven

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

ZOL Genk

Genk, , Belgium

Site Status

UH Leuven

Leuven, , Belgium

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Belgium

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

UH Leuven S53441

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

OCT Guided Magmaris RMS in STEMI
NCT03955731 RECRUITING NA