Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE4
40 participants
INTERVENTIONAL
2011-02-28
2013-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The protocol was approved by Institutional Ethics Committee of University Hospital Dubrava. All participating elective surgical patients were given brief description of the trial, and gave written informed consent before enrolment.
According to a computer generated randomisation list, patients were randomly assigned to receive BIS-guided anesthesia (group 1) or routine anesthesia care as a non BIS-guided group (group 2). The non BIS-guided group was studied while the BIS monitor was attached to patient, but the screen was blinded to the anesthesiologist in charge. All values were recorded by the younger anesthesiologist, who was not involved in the anesthesia maintenance. All other aspects of perioperative treatment were similar, including choice of anesthetic agents and monitoring.
The operation was performed under general anesthesia using midazolam (0.15 mg/kg), fentanyl (2 µg/kg) and pancuronium (0.1 mg/kg) to facilitate endotracheal intubation, and 1.5-2.5 MAC of sevoflurane, nitrous oxide 50% in oxygen, boluses of fentanyl and pancuronium for maintenance. Intraoperatively, after induction doses of fentanyl, anesthesia was mainly balanced with sevoflurane. Electrocardiography (EKG), invasive blood pressure (IBP), peripheral oxygen saturation (SpO2), and end-tidal CO2 (etCO2) were monitored.
A BIS sensor was applied to patient's forehead before induction of anesthesia and connected to A-2000 BIS monitor (Aspect Medical Systems, Newton, MA, USA). It records the electroencephalogram from 4 electrodes and after processing it with mathematic algorithms it generates a number from 0 to 100. When the BIS value is lower than 40, the patient is in deep anesthesia state, when the value is over 80, the patient is under light sedation \[3\].
After the surgery and recovery from anesthesia, patients were transferred to intensive care unit for continuous monitoring of vital functions and homeostasis.
At the induction of anesthesia, and every 15 minutes during operation, BIS levels were recorded. Also, at the end of the operation, extubation time and analgesics consumption were recorded.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
anesthesia monitoring
Bispectral Index Monitoring (BIS) has been proven to be effective in preventing awareness. Optimizing anesthesia level using BIS monitoring, neither to light nor to deep will probably help to shorten recovery time and reduce drug consumption. A BIS sensor was applied to patient's forehead before induction of anesthesia and connected to A-2000 BIS monitor (Aspect Medical Systems, Newton, MA, USA). It records the electroencephalogram from 4 electrodes and after processing it with mathematic algorithms it generates a number from 0 to 100. When the BIS value is lower than 40, the patient is in deep anesthesia state, when the value is over 80, the patient is under light sedation.
bispectral index monitoring
A BIS sensor was applied to patient's forehead before induction of anesthesia and connected to A-2000 BIS monitor (Aspect Medical Systems, Newton, MA, USA). It records the electroencephalogram from 4 electrodes and after processing it with mathematic algorithms it generates a number from 0 to 100. When the BIS value is lower than 40, the patient is in deep anesthesia state, when the value is over 80, the patient is under light sedation.At the induction of anesthesia, and every 15 minutes during operation following parameters were recorded: heart rate (HR), systolic blood pressure (BP), end-tidal CO2 (etCO2) and BIS level. Also, operation time and extubation time were recorded. Finally, all patients were visited on the first postoperative day and interviewed about intraoperative recall.
no bispectral index monitoring
At the induction of anesthesia, and every 15 minutes during operation following parameters were recorded: heart rate (HR), systolic blood pressure (BP), end-tidal CO2 (etCO2) and BIS level. Also, operation time and extubation time were recorded. Finally, all patients were visited on the first postoperative day and interviewed about intraoperative recall.
bispectral index monitoring
A BIS sensor was applied to patient's forehead before induction of anesthesia and connected to A-2000 BIS monitor (Aspect Medical Systems, Newton, MA, USA). It records the electroencephalogram from 4 electrodes and after processing it with mathematic algorithms it generates a number from 0 to 100. When the BIS value is lower than 40, the patient is in deep anesthesia state, when the value is over 80, the patient is under light sedation.At the induction of anesthesia, and every 15 minutes during operation following parameters were recorded: heart rate (HR), systolic blood pressure (BP), end-tidal CO2 (etCO2) and BIS level. Also, operation time and extubation time were recorded. Finally, all patients were visited on the first postoperative day and interviewed about intraoperative recall.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
bispectral index monitoring
A BIS sensor was applied to patient's forehead before induction of anesthesia and connected to A-2000 BIS monitor (Aspect Medical Systems, Newton, MA, USA). It records the electroencephalogram from 4 electrodes and after processing it with mathematic algorithms it generates a number from 0 to 100. When the BIS value is lower than 40, the patient is in deep anesthesia state, when the value is over 80, the patient is under light sedation.At the induction of anesthesia, and every 15 minutes during operation following parameters were recorded: heart rate (HR), systolic blood pressure (BP), end-tidal CO2 (etCO2) and BIS level. Also, operation time and extubation time were recorded. Finally, all patients were visited on the first postoperative day and interviewed about intraoperative recall.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* ASA (American Society of Anesthesiologists) physical status II or III.
Exclusion Criteria
* psychosis,
* known or suspected electroencephalograph abnormality (eg, epilepsy, previous brain operation),
* chronic use of psychoactive medication,
* operation time exceeding six hours.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Hospital Dubrava
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Jasminka Persec, MD, PhD
MD PhD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jasminka Persec, MD PhD
Role: PRINCIPAL_INVESTIGATOR
Anesthesiology, reanimatology and intensive care medicine Clinic, University Hospital Dubrava, Zagreb, Croatia
Zoran Persec, MD PhD
Role: STUDY_CHAIR
Department of urology, University Hospital Dubrava, Zagreb, Croatia
Ino Husedzinovic, Professor
Role: STUDY_DIRECTOR
Head of Anesthesiology, reanimatology and intensive care medicine Clinic, University Hospital Dubrava, Zagreb, Croatia
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital Dubrava
Zagreb, , Croatia
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Persec J, Persec Z, Kopljar M, Sojcic N, Husedzinovic I. Effect of bispectral index monitoring on extubation time and analgesic consumption in abdominal surgery: a randomised clinical trial. Swiss Med Wkly. 2012 Oct 9;142:w13689. doi: 10.4414/smw.2012.13689. eCollection 2012.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
12377KBD
Identifier Type: -
Identifier Source: org_study_id