Dose-response Relationship of Phototherapy for Hyperbilirubinaemia Using Diodes: is There a "Saturation Point"
NCT ID: NCT01470820
Last Updated: 2011-11-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
151 participants
INTERVENTIONAL
2009-07-31
2010-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Objective: To examine the relation between light irradiance and the rate of decrease in total serum bilirubin concentration (TsB) and to see if the investigators can identify a "saturation point", i.e. an irradiation level above which there is no further decrease in TsB.
Design: Prospective randomised study. Setting: Neonatal Intensive Care Unit, Pediatric Department, Aalborg Hospital, Aarhus University Hospital, Denmark.
Material and method: 151 infants with gestational age ≥ 33 weeks and uncomplicated hyperbilirubinaemia are randomised to one of 4 different distances from phototherapy device to mattress (20, 29, 38 and 47 cm). TsB is measured before and after 24 hours of phototherapy and irradiance every 8th hour. Main outcome measure is 24 hours decrease of TsB expressed in percent (∆ TsB0-24 (%)).
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
HEALTH_SERVICES_RESEARCH
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Distance 20 cm
The infants were randomized by sealed and opaque envelopes to one of four phototherapy regimens. Either with distance from the phototherapy device to the mattress of 20, 29, 38 or 47 cm measured by a wood stick for each infant, corresponding to the distances to the infants of averagely 12, 21, 30 and 39 cm, respectively.
Phototherapy with blue light
The infants were placed in a bassinet with the phototherapy device placed above them. All infants were exposed naked (apart from eye pads and diaper) to continuously phototherapy for 24 hours, interrupted only for feeding and nursing for 30 minutes every three hours. TsB was determined before phototherapy and after 24 hours of treatment. The phototherapy apparatus used was neoBLUE LED phototherapy device (Natus Medical Inc., San Carlos, CA, USA) emitting blue light with an emission peak at 460 nm and a bandwidth of 450-470 nm. The irradiance was measured by use of the neoBLUE LED phototherapy radiometer (Natus Medical Inc.) every 8th hour at the infants head, trunk and knees and the average was calculated. The radiometer measures spectral irradiance in the range 420-500 nm with maximum sensitivity in the spectrum 440-480 nm.
Distance 29 cm
Phototherapy with blue light
The infants were placed in a bassinet with the phototherapy device placed above them. All infants were exposed naked (apart from eye pads and diaper) to continuously phototherapy for 24 hours, interrupted only for feeding and nursing for 30 minutes every three hours. TsB was determined before phototherapy and after 24 hours of treatment. The phototherapy apparatus used was neoBLUE LED phototherapy device (Natus Medical Inc., San Carlos, CA, USA) emitting blue light with an emission peak at 460 nm and a bandwidth of 450-470 nm. The irradiance was measured by use of the neoBLUE LED phototherapy radiometer (Natus Medical Inc.) every 8th hour at the infants head, trunk and knees and the average was calculated. The radiometer measures spectral irradiance in the range 420-500 nm with maximum sensitivity in the spectrum 440-480 nm.
Distance 38 cm
Phototherapy with blue light
The infants were placed in a bassinet with the phototherapy device placed above them. All infants were exposed naked (apart from eye pads and diaper) to continuously phototherapy for 24 hours, interrupted only for feeding and nursing for 30 minutes every three hours. TsB was determined before phototherapy and after 24 hours of treatment. The phototherapy apparatus used was neoBLUE LED phototherapy device (Natus Medical Inc., San Carlos, CA, USA) emitting blue light with an emission peak at 460 nm and a bandwidth of 450-470 nm. The irradiance was measured by use of the neoBLUE LED phototherapy radiometer (Natus Medical Inc.) every 8th hour at the infants head, trunk and knees and the average was calculated. The radiometer measures spectral irradiance in the range 420-500 nm with maximum sensitivity in the spectrum 440-480 nm.
Distance 47 cm
Phototherapy with blue light
The infants were placed in a bassinet with the phototherapy device placed above them. All infants were exposed naked (apart from eye pads and diaper) to continuously phototherapy for 24 hours, interrupted only for feeding and nursing for 30 minutes every three hours. TsB was determined before phototherapy and after 24 hours of treatment. The phototherapy apparatus used was neoBLUE LED phototherapy device (Natus Medical Inc., San Carlos, CA, USA) emitting blue light with an emission peak at 460 nm and a bandwidth of 450-470 nm. The irradiance was measured by use of the neoBLUE LED phototherapy radiometer (Natus Medical Inc.) every 8th hour at the infants head, trunk and knees and the average was calculated. The radiometer measures spectral irradiance in the range 420-500 nm with maximum sensitivity in the spectrum 440-480 nm.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Phototherapy with blue light
The infants were placed in a bassinet with the phototherapy device placed above them. All infants were exposed naked (apart from eye pads and diaper) to continuously phototherapy for 24 hours, interrupted only for feeding and nursing for 30 minutes every three hours. TsB was determined before phototherapy and after 24 hours of treatment. The phototherapy apparatus used was neoBLUE LED phototherapy device (Natus Medical Inc., San Carlos, CA, USA) emitting blue light with an emission peak at 460 nm and a bandwidth of 450-470 nm. The irradiance was measured by use of the neoBLUE LED phototherapy radiometer (Natus Medical Inc.) every 8th hour at the infants head, trunk and knees and the average was calculated. The radiometer measures spectral irradiance in the range 420-500 nm with maximum sensitivity in the spectrum 440-480 nm.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Uncomplicated neonatal hyperbilirubinemia
Exclusion Criteria
* infants in incubators
33 Weeks
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Aarhus University Hospital
OTHER
University of Aarhus
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Pernille K Vandborg, MD
Role: PRINCIPAL_INVESTIGATOR
Pediatric department, Aalborg Sygehus, Aarhus University Hospital
Finn Ebbesen, Professor
Role: PRINCIPAL_INVESTIGATOR
Pediatric department, Aalborg Sygehus, Aarhus University Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Pediatric Department, Aalborg Sygehus, Aarhus University Hospital
Aalborg, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Vandborg PK, Hansen BM, Greisen G, Ebbesen F. Dose-response relationship of phototherapy for hyperbilirubinemia. Pediatrics. 2012 Aug;130(2):e352-7. doi: 10.1542/peds.2011-3235. Epub 2012 Jul 16.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
N-20090014
Identifier Type: -
Identifier Source: org_study_id