A Lead Rectangle to Lower the Operator's Radiation Exposure

NCT ID: NCT01469195

Last Updated: 2011-11-10

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

50 participants

Study Classification

OBSERVATIONAL

Study Start Date

2011-12-31

Study Completion Date

2012-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

During fluoroscopic imaging, diagnostic information is carried in the primary beam. These high intensity X-rays are the chief hazard to the patient. Lower energy scattered radiation deviates in all directions from the patient. Despite typical precautions (i.e., hanging a lead shield between the patient and the operator), many operators will be exposed to high radiation dose (higher than the permitted 50 miliS per year), this long term radiation exposure may result in stochastic and deterministic effects. The purpose of this study was to test the hypothesis that a non disposable radiation protection drape (that will cover the lower part of the patient) could help minimize the radiation scattered from the patient to the operator. In a procedure done through the Radial approach, there is a large portion of the patients (from the umbilicus and down) that is a source of scatter radiation to the operator. This portion can be covered with a lead rectangle. A non disposable, lead drape of uniform thickness will be inserted into a sterile nylon bag and will be used during fluoroscopic and cineangiography coronary angioplasty procedures. The lead drapes will cover the femoral puncture site. The widths and length of the drape is 50-60cm and 100 cm respectively and was shown not to hinder the field of radiation needed for fluoroscopy and cineangiography. (The upper border of the lead is under the patient's umbilicus and was shown not to interfere with the radiation field needed for angiography or angioplasty).

The Investigators anticipate that the study will show a significant reduction in radiation exposure and hence reduce the radiation hazard to the operator.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The Investigators tested the hypothesis on a Phantom that contain bones and tissue that simulate human tissue. The above phantom is used in the oncology department for testing radiation protocols delivered to patients. Those preliminary testing showed that a lead rectangle decreased significantly the radiation scattered towards the operators and personnel in the catheterization laboratory. In all chosen places whether 40 or 100 cm from the radiation beam - The Investigators detected a significant reduction in scattered radiation. The significant reduction in these experiments is attributed to the location the Investigators choose but also to the size of the lead drape 100 X60 cm which give a large area of protection. From simple geometric calculations it's understandable that the zone or volume of radiation protection become much larger further away from the lead rectangle.Patients who are admitted for an elective PCI procedure ( or stable ACS patients) will be ask to participate in the study and sign an informed consent. All the procedure will be as standard of care, after cleaning the right or left arm, and the groin a sterile towel will cover the groin, on top of the sterile towel the lead rectangle (that by itself will be inserted to a sterile nylon bag) will be put over to cover the area from the umbilicus and down.

(In case that the radial approach will fail and femoral approach will be needed, it is easy to remove the lead rectangle while keeping sterile field in the groin area). Few dosimeters will be used to assess radiation exposure, two underneath the lead apron, one on top, and two dosimeters for the operator (two detecting the radiation exposure in the neck area).

The Investigators will approach patients in whom a long procedure time and higher radiation exposure are anticipated (like patients with chronic total occlusion, heavily calcified or tortuous coronary arteries). In those, the fluoroscopy time on average, is longer than usual.

A total of 50 patients will be recruited (based on the Investigators preliminary radiation testing on the phantom and the results of Politi et al). In 25 patients a lead rectangle will be used on top of the regular protection (personal lead suit, leaded glass shield), in 25 patients only regular protection for the operators.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atherosclerosis Coronary Occlusion Coronary Artery Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CONTROL

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Group A - No lead protection

Patients who are admitted for an elective percutaneous coronary intervention procedure ( or stable acute coronary syndrome patients) will be ask to participate in the study and sign an informed consent (see inclusions and exclusions).The Investigators will approach patients in whom a long procedure time and higher radiation exposure are anticipated (like patients with chronic total occlusion, heavily calcified or tortuous coronary arteries). In those, the fluoroscopy time on average, is longer than usual. In group A - no lead protection will be used.

No interventions assigned to this group

Group B plus lead protection

Patients who are admitted for an elective percutaneous coronary intervention procedure ( or stable acute coronary syndrome patients) will be ask to participate in the study and sign an informed consent (see inclusions and exclusions).The Investigators will approach patients in whom a long procedure time and higher radiation exposure are anticipated (like patients with chronic total occlusion, heavily calcified or tortuous coronary arteries). In those, the fluoroscopy time on average, is longer than usual. In group B - lead protection will be used from the umbilicus and down.

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* patients referred for an elective (non emergent) - radial access approach for coronary angioplasty.
* patients with angina pectoris or acute coronary syndrome, which are hemodynamically stable, will be included.
* Age 18-75.

Exclusion Criteria

* Urgent/Emergent procedures (ST elevation myocardial infarction, suspected LM disease, low Ejection fraction \<35%, patients in heart failure - NYHA class III, IV).
* Any situation that there is higher chance (over 10%) of switching to a femoral access approach (like weak radial pulse, low blood pressure \<90 mmHg, failed radial access in the past) .
* Significant valve disease like; severe aortic stenosis, severe mitral regurgitation.
* Pregnancy or women in child bearing age.
Minimum Eligible Age

18 Years

Maximum Eligible Age

75 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Sunnybrook Health Sciences Centre

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Bradley H Strauss, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Sunnybrook Health Sciences Centre, Schulich Heart program Devision of Cardiology Toronto Ontario, Canada

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Sunnybrook health sciences centre

Toronto, Ontario, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Bradley H Strauss, MD PhD

Role: CONTACT

416 480 6066

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Bradley H Strauss, MD, PhD

Role: primary

416480-6066

References

Explore related publications, articles, or registry entries linked to this study.

Politi L, Biondi-Zoccai G, Nocetti L, Costi T, Monopoli D, Rossi R, Sgura F, Modena MG, Sangiorgi GM. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield. Catheter Cardiovasc Interv. 2012 Jan 1;79(1):97-102. doi: 10.1002/ccd.22947. Epub 2011 Apr 25.

Reference Type BACKGROUND
PMID: 21520391 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

RAD410OSH

Identifier Type: -

Identifier Source: org_study_id