Feasibility Study of a Portable Artificial Pancreas System in Type 1 Diabetes Mellitus (T1DM) - Montpellier

NCT ID: NCT01447979

Last Updated: 2012-11-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

EARLY_PHASE1

Total Enrollment

5 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-03-31

Study Completion Date

2012-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

A single arm, single treatment study is proposed to assess the feasibility of a portable artificial pancreas system outside of a hospital based clinical research center.

Adult T1DM patients will use a newly developed platform in conjunction with a subcutaneous insulin infusion pump and a continuous glucose monitor for 18 hours is quasi free conditions (hotel).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Automated closed-loop control (CLC), known as "artificial pancreas" (AP) can have tremendous impact on the health and lives of people with type 1 diabetes (T1D). Our inter-institutional and international research team has been on the forefront of CLC developments since the beginning of the JDRF Artificial Pancreas initiative in 2006. Thus far, we have conducted three closed-loop control clinical trials (totaling 60 subjects with T1D), which demonstrated significantly more time in an acceptable "target" blood glucose range during CLC, and significantly fewer hypoglycemic events during CLC compared to open loop. Our overall objective is to sequentially test, validate, obtain regulatory approval for, and deploy at home, a closed-loop Control-to-Range (CTR) system comprised of two algorithmic components: a Safety Supervision Module (SSM) and an automated Range Correction Module (RCM). The SSM will monitor the safety of the subject's continuous subcutaneous insulin infusion pump (CSII) to prevent hypoglycemia, and will also monitor the integrity of continuous glucose monitor (CGM) data for signal sensor deviations or loss of sensitivity. The RCM will be responsible for the optimal regulation of postprandial hyperglycemic excursions through correction boluses.

The first phase to address our overall objective is a pilot study that will test the ability of a cell-phone-based system to (1) run CTR in an outpatient setting, and (2) be remotely monitored. Specifically, this pilot study entails a hybrid hotel/hospital design targeting adults with T1D that are experienced insulin pump users. Subjects will spend one night in a local hotel, during which the phone-based system will be remotely monitored in an adjacent hotel room for validation that remote system monitoring can successfully occur. Subjects will spend the following day in the hospital, where CTR will be activated, and challenged with meals and a CGM sensor replacement . Subjects will then spend a second night in the hotel for continued evaluation of remote system monitoring, along with outpatient testing of the CTR system run on the phone-based system. This series of admissions will address the first major hurdles that need to be overcome for home deployment of a closed loop CTR system:

Specific Aim 1: The phone-based CTR system can be remotely monitored by nurses/physicians/technicians to confirm appropriate functioning outside of the hospital setting.

Specific Aim 2: The CTR can be deployed outside of the hospital setting.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Type 1 Diabetes Mellitus

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Artificial Pancreas Insulin Pump Continuous Glucose Monitor Closed Loop

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

All patients

this is the only arm of the study, and concerns all patients.

Group Type EXPERIMENTAL

portable artificial pancreas system with Control-To-Range algorithms

Intervention Type DEVICE

The investigators will test the new portable CTR system in CRC conditions for 10h followed by 18h of CTR in a hotel.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

portable artificial pancreas system with Control-To-Range algorithms

The investigators will test the new portable CTR system in CRC conditions for 10h followed by 18h of CTR in a hotel.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patient must be aged between 21 (inclusive) and 65 years old. The age of 21 has been chosen because this trial is supported by a US Foundation.
* Patient must have been clinically diagnosed with Type 1 diabetes mellitus. For an individual to be enrolled at least one criterion from each list must be met:

* Criteria for documented hyperglycemia (at least 1 must be met):

* Fasting glucose ≥126 mg/dL - confirmed
* Two-hour OGTT glucose ≥200 mg/dL - confirmed
* HbA1c ≥6.5% documented - confirmed
* Random glucose ≥200 mg/dL with symptoms
* No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes
* Criteria for requiring insulin at diagnosis (1 must be met):

* Participant required insulin at diagnosis and continually thereafter
* Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually
* Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with latent autoimmune diabetes in adults (LADA) and did require insulin eventually and used continually
* Use of an insulin pump to treat his/her diabetes for at least 1 year
* Actively using a carbohydrate \[CHO\] / insulin ratio for insulin bolus adjustments in order to keep blood glucose in a predefined range
* Patient HbA1c is between 6.0% and 9% as measured with DCA2000 or equivalent device
* Patient must demonstrate proper mental status and cognition for the study
* Patient must be willing to avoid consumption of acetaminophen-containing products during the study interventions involving DexCom use
* Patient must be affiliated or beneficiary of a social medical insurance
* Patient has signed informed consent form prior to study entry

Exclusion Criteria

* Diabetic ketoacidosis within the 6 months prior to enrollment
* Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
* Pregnancy, breast feeding, or intention of becoming pregnant
* Uncontrolled arterial hypertension (diastolic blood pressure \>90 mmHg and/or systolic blood pressure \>160 mmHg)
* Conditions which may increase the risk of hypoglycemia such as uncontrolled coronary artery disease during the previous year (e.g. history of myocardial infarction, acute coronary syndrome, therapeutic coronary intervention, coronary bypass or stenting procedure, stable or unstable angina, episode of chest pain of cardiac etiology with documented EKG changes, or positive stress test or catheterization with coronary blockages \>50%), congestive heart failure, history of cerebrovascular event, seizure disorder, syncope, adrenal insufficiency, neurologic disease or atrial fibrillation
* History of a systemic or deep tissue infection with methicillin-resistant staph aureus or Candida albicans
* Use of a device that may pose electromagnetic compatibility issues and/or radiofrequency interference with the DexCom CGM (implantable cardioverter-defibrillator, electronic pacemaker, neurostimulator, intrathecal pump, and cochlear implants)
* Anticoagulant therapy other than aspirin
* Oral steroids
* Medical condition requiring use of an acetaminophen-containing medication that cannot be withheld for the study admissions.
* Psychiatric disorders that would interfere with study tasks (e.g. inpatient psychiatric treatment within 6 months prior to enrollment)
* Mental incapacity, unwillingness or language barriers precluding adequate understanding or cooperation
* Known current or recent alcohol or drug abuse
* Medical conditions that would make operating a CGM, cell phone, or insulin pump difficult (e.g. blindness, severe arthritis, immobility)
* Any skin condition that prevents sensor or pump placement on the abdomen or arm (e.g. bad sunburn, pre-existing dermatitis, intertrigo, psoriasis, extensive scarring, cellulitis)
* Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase ≥three times the upper reference limit
* Impaired renal function measured as creatinine \>1.2 times above the upper limit of normal
* Uncontrolled microvascular (diabetic) complications (other than diabetic non-proliferative retinopathy), such as history of laser coagulation, proliferative diabetic retinopathy, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring treatment
* Active gastroparesis requiring current medical therapy
* If on antihypertensive, thyroid, anti-depressant or lipid lowering medication, lack of stability on the medication for the past 2 months prior to enrollment in the study
* Uncontrolled thyroid disease
* Known bleeding diathesis or dyscrasia
* Known allergy to medical adhesives, components of the insulin pump insertion set or continuous glucose monitor sensor
* Unwillingness to withhold dietary supplements two weeks prior to admission and for the duration of the study participation.
* Unwillingness to withhold pramlintide, liraglutide and exenatide for the duration of the study intervention.
* Patient is actively enrolled in another clinical trial or was part of study within 30 days or whose annual study income is over 4 500€
* Persons deprived of freedom, adults protected by law or vulnerable persons
Minimum Eligible Age

21 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital, Montpellier

OTHER

Sponsor Role collaborator

University of Padova

OTHER

Sponsor Role collaborator

University of California, Santa Barbara

OTHER

Sponsor Role collaborator

University of Virginia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Eric Renard, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

University of Montpellier Hospital

Boris Kovatchev, PhD

Role: STUDY_DIRECTOR

University of Virginia

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Centre d'Investigation Clinique CHU Montpellier

Montpellier, , France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

References

Explore related publications, articles, or registry entries linked to this study.

Kovatchev BP, Renard E, Cobelli C, Zisser HC, Keith-Hynes P, Anderson SM, Brown SA, Chernavvsky DR, Breton MD, Farret A, Pelletier MJ, Place J, Bruttomesso D, Del Favero S, Visentin R, Filippi A, Scotton R, Avogaro A, Doyle FJ 3rd. Feasibility of outpatient fully integrated closed-loop control: first studies of wearable artificial pancreas. Diabetes Care. 2013 Jul;36(7):1851-8. doi: 10.2337/dc12-1965.

Reference Type DERIVED
PMID: 23801798 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

JDRF 22-2011-649

Identifier Type: OTHER_GRANT

Identifier Source: secondary_id

2011-A01096-35

Identifier Type: -

Identifier Source: org_study_id