Clinical Trail of Transtek Glass Body Fat Analyzer

NCT ID: NCT01440894

Last Updated: 2011-09-27

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

50 participants

Study Classification

OBSERVATIONAL

Study Start Date

2011-02-28

Study Completion Date

2011-02-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The clinical protocol of the clinical testing of this device:

1. Objective of the test: To verify the functions and efficiency of devices.
2. Test methods and procedures: Comparison Test.
3. DUT(Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.
4. Comparison device: Transtek Glass Body Analyzer, GBF-950 (Predicate Device).
5. Study endpoints: Transtek devices and the predicate device are substantial equivalence.
6. Statistical methodology used: Description of statistical methods.
7. Result: Efficiencies of Transtek devices and predicate device are in the same level.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Hospital Information The data was collected by Zhongshan City People's Hospital Clinical Investigator Team at Zhongshan City People's Hospital, No.2 Sunwen Dong Road, Zhongshan, Guangdong 528403, P. R. China.

Investigator: Dr. Stephen Feng, Leader; Fan Futao, Nurse A; Wu Yanting, Nurse B.

Contact Dr. James Zhu Tel: +86 760 88823818 Used Equipments DUT (Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.

Reference Device: Transtek Glass Body Analyzer, GBF-950 (Predicate Device). Test Protocol

1. Test Purpose:

The aim of clinical test is to collect weight, body fat, total body water, bone mass, and muscle mass reading value which measured by DUT and reference device.

Note: GBF-733-W1 and BF-1039 have not bone mass functions. So it just collects weight, body fat, total body water, and muscle mass data.
2. Target Subject:

The subject database shall contain at least 25 male and 25 female subjects and all above 18 years old. Patient's population analysis is bellow.
3. Test procedures 1) Record the name, age, and gender values of each subject. 2) Let subject seated calmly for two minutes before test, dry the feet. 3) Use device to measure weight, body fat, total body water, bone mass, and muscle mass; record reading value.

4\) For each subject, repeat 3) to get 3 pairs measurements. 5) Repeat step 1) to 4) for every device (DUT: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D; and reference device: GBF-950).

6\) Repeat step 1) to 5) for each subject. 5. Note:

1. No motion and speaking are allowed during the measurement.
2. All DUT use the same algorithms, have the same number of electrodes and contact the patient at the same body locations (feet), and operate on the same frequency.
3. Test environment: Temperature: 22±1℃; Relative humidity: 40\~50%.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Weight Body Fat Disorder Bone Mass

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Body Analysis

Comparison test

Intervention Type DEVICE

Reference Device: Transtek Glass Body Analyzer, GBF-950, accuracy: ±0.1kg and range: 0-180kg.

DUT(Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Comparison test

Reference Device: Transtek Glass Body Analyzer, GBF-950, accuracy: ±0.1kg and range: 0-180kg.

DUT(Device Under Test): Transtek Glass Body Fat Analyzer, Model: GBF-733-W1, GBF-1012, BF-1039, BF-1041-A, and GBF-950-D.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Brand name: Transtek

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* male,female

Exclusion Criteria

* below 18 years old
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

BTS International

OTHER

Sponsor Role collaborator

Leo Wang

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Leo Wang

Team leader

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Stephen Feng, Director

Role: PRINCIPAL_INVESTIGATOR

Zhongshan People's Hospital, Guangdong, China

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Zhongshan City People's Hospital

Zhongshan, Guangdong, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

BTS-TRANS03

Identifier Type: OTHER

Identifier Source: secondary_id

TranstekGBFA11003

Identifier Type: -

Identifier Source: org_study_id