Trial Outcomes & Findings for Study on OsseoSpeed™ TX Implants in a Chinese Population (NCT NCT01346683)
NCT ID: NCT01346683
Last Updated: 2019-09-27
Results Overview
Marginal Bone Level determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant. Marginal Bone Level expressed in millimeters at the 3 year follow-up visit compared to values obtained at delivery of permanent restoration i.e. loading (baseline).
COMPLETED
NA
45 participants
Evaluated 3 years after implant loading
2019-09-27
Participant Flow
Unit of analysis: Implants
Participant milestones
| Measure |
OsseoSpeed TX
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Overall Study
STARTED
|
45 107
|
|
Overall Study
COMPLETED
|
45 107
|
|
Overall Study
NOT COMPLETED
|
0 0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Study on OsseoSpeed™ TX Implants in a Chinese Population
Baseline characteristics by cohort
| Measure |
OsseoSpeed TX
n=107 Implants
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Age, Continuous
|
55.5 years
STANDARD_DEVIATION 10.21 • n=5 Participants
|
|
Sex: Female, Male
Female
|
26 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
19 Participants
n=5 Participants
|
|
Region of Enrollment
China
|
45 participants
n=5 Participants
|
PRIMARY outcome
Timeframe: Evaluated 3 years after implant loadingPopulation: Protocol deviations excluded, a total of 5 subjects (15 implants), resulting in a per protocol analysis population of 40 subjects (92 implants). In addition a total of 2 subjects (4 implants) had radiographs were not possible measure. Giving an analysis population of 38 subjects (88 implants) for the primary outcome measure.
Marginal Bone Level determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant. Marginal Bone Level expressed in millimeters at the 3 year follow-up visit compared to values obtained at delivery of permanent restoration i.e. loading (baseline).
Outcome measures
| Measure |
OsseoSpeed TX
n=88 Implants
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Marginal Bone Level Alteration
|
0.10 millimeter
Standard Deviation 0.61
|
SECONDARY outcome
Timeframe: From implant placement to the follow-up 36 months after loading.Population: Protocol deviations excluded, a total of 5 subjects (15 implants), resulting in a per protocol analysis population of 40 subjects (92 implants).
Implant survival rate evaluated clinically and radiographically.
Outcome measures
| Measure |
OsseoSpeed TX
n=92 Implants
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Implant Survival
|
92 Implants
|
SECONDARY outcome
Timeframe: Measured from loading of implants to the follow-up 36 months after loading.Population: Protocol deviations excluded, a total of 5 subjects (15 implants), resulting in a per protocol analysis population of 40 subjects (92 implants).
Implant stability evaluated clinically/manually (recorded as stable yes/no)
Outcome measures
| Measure |
OsseoSpeed TX
n=92 Implants
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Implant Stability
|
92 Implants
|
SECONDARY outcome
Timeframe: Measured from loading of implants to the follow-up 36 months after loading.Population: Protocol deviations excluded, a total of 5 subjects (15 implants), resulting in a per protocol analysis population of 40 subjects (92 implants).
Soft tissue status measured by assessment of probing pocket depth (PPD). PPD was measured at 4 different surfaces (mesial, distal, buccal and lingual) and change compared to baseline (loading) was analyzed. A negative value = increased pocket depth.
Outcome measures
| Measure |
OsseoSpeed TX
n=92 Implants
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Soft Tissue Status (PPD).
|
-0.77 millimeter
Standard Deviation 0.95
|
SECONDARY outcome
Timeframe: Measured from loading of implants to the follow-up 36 months after loading.Population: Protocol deviations excluded, a total of 5 subjects (15 implants), resulting in a per protocol analysis population of 40 subjects (92 implants).
Soft tissue status measured by assessment of bleeding on probing (BoP).
Outcome measures
| Measure |
OsseoSpeed TX
n=92 Implants
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Soft Tissue Status (BoP)
|
30 Implants
|
Adverse Events
OsseoSpeed TX
Serious adverse events
| Measure |
OsseoSpeed TX
n=45 participants at risk
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Cardiac disorders
Atrial Fibrillation
|
2.2%
1/45 • Number of events 1 • 3 years
|
Other adverse events
| Measure |
OsseoSpeed TX
n=45 participants at risk
OsseoSpeed TX implants of lengths 8-17 mm
|
|---|---|
|
Infections and infestations
Common cold
|
6.7%
3/45 • Number of events 5 • 3 years
|
Additional Information
Manager Global Clinical Research
Dentsply Sirona Implants, Mölndal, SWEDEN
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place
Restriction type: LTE60