Trial Outcomes & Findings for A Study Evaluating OsseoSpeed TX Using Different Drilling Protocols With Immediate Loading (NCT NCT01340170)
NCT ID: NCT01340170
Last Updated: 2024-11-15
Results Overview
Marginal Bone Level alterations will be determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant.
COMPLETED
NA
168 participants
Implant insertion and 12 months post implant insertion
2024-11-15
Participant Flow
Unit of analysis: Implants
Participant milestones
| Measure |
Standard Drilling Protocol (Group A)
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Group A + B
Subjects with implants from both Group A and Group B
|
|---|---|---|---|
|
Overall Study
STARTED
|
79 83
|
86 99
|
3 6
|
|
Overall Study
Permanent Restoration (Start + 3 Months)
|
79 83
|
81 94
|
3 6
|
|
Overall Study
COMPLETED
|
76 79
|
79 91
|
3 6
|
|
Overall Study
NOT COMPLETED
|
3 4
|
7 8
|
0 0
|
Reasons for withdrawal
| Measure |
Standard Drilling Protocol (Group A)
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Group A + B
Subjects with implants from both Group A and Group B
|
|---|---|---|---|
|
Overall Study
Lost to Follow-up
|
2
|
4
|
0
|
|
Overall Study
Implant failure
|
1
|
3
|
0
|
Baseline Characteristics
Race and Ethnicity were not collected from any participant.
Baseline characteristics by cohort
| Measure |
Standard Drilling Protocol (Group A)
n=79 Participants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=86 Participants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Group A + B
n=3 Participants
Subjects with implants from both Group A and Group B
|
Total
n=168 Participants
Total of all reporting groups
|
|---|---|---|---|---|
|
Age, Continuous
|
46.6 Years
STANDARD_DEVIATION 12.6 • n=79 Participants
|
47.5 Years
STANDARD_DEVIATION 12.3 • n=86 Participants
|
54.3 Years
STANDARD_DEVIATION 17.7 • n=3 Participants
|
47.2 Years
STANDARD_DEVIATION 12.5 • n=168 Participants
|
|
Sex: Female, Male
Female
|
43 Participants
n=79 Participants
|
44 Participants
n=86 Participants
|
3 Participants
n=3 Participants
|
90 Participants
n=168 Participants
|
|
Sex: Female, Male
Male
|
36 Participants
n=79 Participants
|
42 Participants
n=86 Participants
|
0 Participants
n=3 Participants
|
78 Participants
n=168 Participants
|
|
Race and Ethnicity Not Collected
|
—
|
—
|
—
|
0 Participants
Race and Ethnicity were not collected from any participant.
|
PRIMARY outcome
Timeframe: Implant insertion and 12 months post implant insertionPopulation: ITT subjects with MBL data available (MBL data missing for 14 implants in Group A, and from 10 implants in group B). Outcome measure 1 is analyzed on implant level only and does not contain subject level group "Group A + B".
Marginal Bone Level alterations will be determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=68 Implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=84 Implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Marginal Bone Level Change
|
-0.25 mm
Standard Deviation 0.9
|
-0.2 mm
Standard Deviation 0.67
|
SECONDARY outcome
Timeframe: Implant insertion and 3 months post implant insertionPopulation: ITT subjects with MBL data available (MBL data missing from 10 implants in Group A, from 9 implants in group B). Outcome measure 2 is analyzed on implant level only and does not contain subject level group "Group A + B".
Marginal Bone Level alterations will be determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=76 Implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=88 Implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Marginal Bone Level Change
|
-0.2 mm
Standard Deviation 0.62
|
-0.29 mm
Standard Deviation 0.67
|
SECONDARY outcome
Timeframe: 12 months after baseline, i.e., implant insertionPopulation: ITT subjects at 12 months as well as known implant failures already terminated are included in the analysis. Outcome measure 3 is analyzed on implant level only and does not contain subject level group "Group A + B".
Implant survival rate will be evaluated by both clinically and radiographically counting the number of remaining implants from implant placement to one year after loading.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=84 Implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=98 Implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Implant Survival Rate
Implants confirmed success
|
82 Implants
|
94 Implants
|
|
Implant Survival Rate
Implants confirmed failure
|
2 Implants
|
4 Implants
|
SECONDARY outcome
Timeframe: At implant insertionPopulation: ITT population. Outcome measure 4 is analyzed on implant level only and does not contain subject level group "Group A + B".
Evaluated clinically/manually and recorded as stable yes/no.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=86 Implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=102 Implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Implant Stability Assessed Clinically/Manually
Implant stability - No
|
0 Implants
|
5 Implants
|
|
Implant Stability Assessed Clinically/Manually
Implant stability - Yes
|
86 Implants
|
97 Implants
|
SECONDARY outcome
Timeframe: At implant insertion.Population: ITT population. Outcome measure 5 is analyzed on implant level only and does not contain subject level group "Group A + B".
The Osstell® instrument "Osstell® ISQ" will be used to measure RFA. RFA measures the frequency with which a device vibrates. By comparing resonance frequencies the stability of a dental implant can be determined as the resonance frequency changes with different stability. The Osstell® ISQ instrument translates the RFA value into an Implant Stability Quotient (ISQ) scale value. ISQ is a scale from 1 to 100. The ISQ scale has a non-linear correlation to micro mobility, with a higher value corresponding to increased stability.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=86 Implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=102 Implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Implant Stability Using Resonance Frequency Analysis (RFA)
Mesio-Distal
|
78.6 ISQ on implant level
Standard Deviation 6.2
|
77.5 ISQ on implant level
Standard Deviation 9.6
|
|
Implant Stability Using Resonance Frequency Analysis (RFA)
Bucco-Palatinal
|
78.8 ISQ on implant level
Standard Deviation 5.9
|
77.7 ISQ on implant level
Standard Deviation 9.4
|
SECONDARY outcome
Timeframe: After implant insertionPopulation: ITT subjects. Outcome measure 6 is analyzed on implant level only and does not contain subject level group "Group A + B".
After implant insertion, a questionnaire will be completed for each study implant by the surgeon. The questionnaire contains following statements "The implant was guided into the prepared osteotomy", "The implant followed the prepared osteotomy" and "The implant has a good primary stability". The surgeon records his/her response to each statement with a number from 1 to 10 , where 1= totally disagree with the statement, and 10= totally agree with the statement.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=86 Implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=102 Implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Perception During Implant Insertion - "The Implant Was Guided Into the Prepared Osteotomy"
|
7.5 score on a scale
Standard Deviation 2.6
|
7.1 score on a scale
Standard Deviation 2.4
|
SECONDARY outcome
Timeframe: After implant insertionPopulation: ITT subjects. Outcome measure 7 is analyzed on implant level only and does not contain subject level group "Group A + B".
After implant insertion, a questionnaire will be completed for each study implant by the surgeon. The questionnaire contains following statements "The implant was guided into the prepared osteotomy", "The implant followed the prepared osteotomy" and "The implant has a good primary stability". The surgeon records his/her response to each statement with a number from 1 to 10 , where 1= totally disagree with the statement, and 10= totally agree with the statement.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=86 implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=102 implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Perception During Implant Insertion - "The Implant Followed the Prepared Osteotomy"
|
8.2 score on a scale
Standard Deviation 1.6
|
7.6 score on a scale
Standard Deviation 2.0
|
SECONDARY outcome
Timeframe: After implant insertionPopulation: ITT subjects. Outcome measure 8 is analyzed on implant level only and does not contain subject level group "Group A + B".
After implant insertion, a questionnaire will be completed for each study implant by the surgeon. The questionnaire contains following statements "The implant was guided into the prepared osteotomy", "The implant followed the prepared osteotomy" and "The implant has a good primary stability". The surgeon records his/her response to each statement with a number from 1 to 10 , where 1= totally disagree with the statement, and 10= totally agree with the statement.
Outcome measures
| Measure |
Standard Drilling Protocol (Group A)
n=86 implants
A standard drilling protocol will be used in bone quality 1 and 2
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
Soft Bone Drilling Protocol (Group B)
n=102 implants
A soft bone drilling protocol will be used in bone quality 3 and 4
OsseoSpeed TX: OsseoSpeed TX dental implants, 6-17 mm
|
|---|---|---|
|
Perception During Implant Insertion - "The Implant Has a Good Primary Stability"
|
8.7 score on a scale
Standard Deviation 1.3
|
8.1 score on a scale
Standard Deviation 1.7
|
Adverse Events
Standard Drilling Protocol (Group A)
Soft Bone Drilling Protocol (Group B)
Group A + B
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Manager of Global Clinical Reseach
Dentsply Sirona Implants
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place