Clinical Test for Transtek Glass Body Analyzer

NCT ID: NCT01296048

Last Updated: 2011-12-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

74 participants

Study Classification

OBSERVATIONAL

Study Start Date

2010-11-30

Study Completion Date

2010-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The clinical protocol of the clinical testing of this device:

1. Objective of the test: To verify the functions and efficiency of devices.
2. Test methods and procedures: Comparison Test.
3. DUT: Transtek Glass Body Analyzer, Model: GBF-830, GBF-835, GBF-950, and SA-15.
4. Comparison device: Scaleman Body Fat Scales, FS-148BW1 (Predicate Device).
5. Study endpoints: Transtek devices and the predicate device are substantial equivalence.
6. Statistical methodology used: Description of statistical methods.
7. Result: Efficiencies of Transtek devices and predicate device are in the same level.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Hospital Information The data was collected by West China Medical College Clinical Investigator Team at Wuhou District Hospital, No. 9 Tongzilin Road, Wuhou District, Chengdu 610041, P. R. China.

Investigator: Catharine Zhang, Nurse A; Vivian Luo, Nurse B; Dr. James Zhu, Sponsor.

Contact Dr. James Zhu Tel: +86 1330 8036568 Used Equipments DUT (Device Under Test): Transtek Glass Body Analyzer, GBF-830, GBF-835, GBF-950, and SA-15.

Reference Device: Scaleman Body Fat Scales, FS-148BW1 (Predicate Device). Test Protocol

1. Test Purpose:

The aim of clinical test is to collect weight, body fat, total body water, bone mass, and muscle mass reading value which measured by DUT and reference device.

Note: GBF-835 has not total body water, bone mass, and muscle mass functions. So it just collects weight and body fat data.
2. Target Subject:

The subject database shall contain at least 25 male and 25 female subjects and all above 18 years old. Patient's population analysis is bellow.
3. Test procedures 1) Record the name, age, gender, and height of each subject. 2) Let subject seated calmly for two minutes before test, dry the feet. 3) Use device to measure weight, body fat, total body water, bone mass, and muscle mass; record reading value.

4\) For each subject, repeat 3) to get 3 pairs measurements. 5) Repeat step 1) to 4) for every device (DUT: GBF-830, GBF-835, GBF-950, and SA-15; and reference device: FS-148BW1).

6\) Repeat step 1) to 5) for each subject. 5. Note:

1. No motion and speaking are allowed during the measurement.
2. All DUT use the same algorithms, have the same number of electrodes and contact the patient at the same body locations (feet), and operate on the same frequency.
3. Test environment: Temperature: 20±1℃; Relative humidity: 40\~50%.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Weight Body Fat Disorder Bone Mass

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

weight body fat total body water bone mass muscle mass

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Body Analysis

Comparison test

Intervention Type DEVICE

Scaleman Body Fat Scales, FS-148BW1, accuracy: ±0.1kg and range: 0-180kg.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Comparison test

Scaleman Body Fat Scales, FS-148BW1, accuracy: ±0.1kg and range: 0-180kg.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Brand names: Scaleman Serial numbers: SBFS1002-351 Code name: FS-148BW1

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* male,female

Exclusion Criteria

* below 18 years old
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

West China Hospital

OTHER

Sponsor Role collaborator

Leo Wang

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Leo Wang

Team Leader

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Guoqing Li, Director

Role: PRINCIPAL_INVESTIGATOR

Wuhou District Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Wuhou District Hospital

Chengdu, Sichuan, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

BTS-TRANS02

Identifier Type: OTHER

Identifier Source: secondary_id

Transtek GBA

Identifier Type: -

Identifier Source: org_study_id