Use of Heliox Associated With PEEP in Patients With Asthma
NCT ID: NCT01268462
Last Updated: 2010-12-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
32 participants
INTERVENTIONAL
2009-07-31
2010-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Heliox + PEP (Group 1)
Heliox+PEP
For the nebulization with heliox was used radioaerosol a noninvasive delivery system that consists of a nontoxic orofacial mask with two unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). This mask was attached to the patient's face to prevent leaks and maintain proper pressurization and better patient compliance to the PEP. PEP was offered to 10 cm H2O through valve (Vital Signs, Totowa, NY) attached to the expiratory branch. The nebulizer was fed by a flow of 11 l / min of heliox for the heliox group according to the protocol of Hess et al. When powered by heliox mixture, the flow was adjusted flowmeter suitable for this mixture.
Oxygen+PEP(Group 2)
Oxygen+PEP
For nebulization of radioaerosol with oxygen, we used a noninvasive delivery system that consists of a mask with two nontoxic orofacial unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). This mask was attached to the patient's face to prevent leaks and maintain proper pressurization and better patient compliance to PEP (Figure 2). PEP was offered to 10 cm H2O through valve (Vital Signs, Totowa, NY) attached to the expiratory branch. The nebulizer was fed by a stream of 8 l / min oxygen.
Heliox ( Group 3)
Heliox
For the nebulization with heliox we used a noninvasive delivery system that consists of a nontoxic orofacial mask with two unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). We used a PEP valve without resistance.
Oxygen (Group 4)
Oxygen
For nebulization of radioaerosol with oxygen, we used a noninvasive delivery system that consists of a mask with two nontoxic orofacial unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). We used a PEP valve without resistance.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Heliox+PEP
For the nebulization with heliox was used radioaerosol a noninvasive delivery system that consists of a nontoxic orofacial mask with two unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). This mask was attached to the patient's face to prevent leaks and maintain proper pressurization and better patient compliance to the PEP. PEP was offered to 10 cm H2O through valve (Vital Signs, Totowa, NY) attached to the expiratory branch. The nebulizer was fed by a flow of 11 l / min of heliox for the heliox group according to the protocol of Hess et al. When powered by heliox mixture, the flow was adjusted flowmeter suitable for this mixture.
Oxygen+PEP
For nebulization of radioaerosol with oxygen, we used a noninvasive delivery system that consists of a mask with two nontoxic orofacial unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). This mask was attached to the patient's face to prevent leaks and maintain proper pressurization and better patient compliance to PEP (Figure 2). PEP was offered to 10 cm H2O through valve (Vital Signs, Totowa, NY) attached to the expiratory branch. The nebulizer was fed by a stream of 8 l / min oxygen.
Heliox
For the nebulization with heliox we used a noninvasive delivery system that consists of a nontoxic orofacial mask with two unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). We used a PEP valve without resistance.
Oxygen
For nebulization of radioaerosol with oxygen, we used a noninvasive delivery system that consists of a mask with two nontoxic orofacial unidirectional valves - inspiratory and expiratory branch - connected to the nebulizer for radioisotopes Venticis ® II Medical device, class II, CE 0459 (Ventibox / CIS Bio International, France). We used a PEP valve without resistance.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* FEV1 \<60% predicted more than one year
* Reversibility of bronchial obstruction after administration of bronchodilators at least 10% in FEV1 on spirometry.
Exclusion Criteria
* History of smoking over the past three years associated with a consumption greater than 100 cigarettes per year or who had history of smoking increased 10 years
* pulmonary comorbidities such as COPD, bronchiectasis and tuberculosis sequelae
* Pregnancy and any contraindication to the use of PEP, such as active hemoptysis, sinusitis, surgery or facial trauma, oral or injury, epistaxis, esophageal surgery and nausea.
18 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Universidade Federal de Pernambuco
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Universidade Federal de Pernambuco
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hospital das Clínicas
Recife, Pernambuco, Brazil
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Piva JP, Menna Barreto SS, Zelmanovitz F, Amantea S, Cox P. Heliox versus oxygen for nebulized aerosol therapy in children with lower airway obstruction. Pediatr Crit Care Med. 2002 Jan;3(1):6-10. doi: 10.1097/00130478-200201000-00002.
Hess DR, Acosta FL, Ritz RH, Kacmarek RM, Camargo CA Jr. The effect of heliox on nebulizer function using a beta-agonist bronchodilator. Chest. 1999 Jan;115(1):184-9. doi: 10.1378/chest.115.1.184.
Alcoforado L, Brandao S, Rattes C, Brandao D, Lima V, Ferreira Lima G, Fink JB, Dornelas de Andrade A. Evaluation of lung function and deposition of aerosolized bronchodilators carried by heliox associated with positive expiratory pressure in stable asthmatics: a randomized clinical trial. Respir Med. 2013 Aug;107(8):1178-85. doi: 10.1016/j.rmed.2013.03.020. Epub 2013 May 9.
Related Links
Access external resources that provide additional context or updates about the study.
Related Info
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
31012010
Identifier Type: -
Identifier Source: org_study_id