Trial Outcomes & Findings for Examining the Ease of Intubation Using the Parker Flex-Tip® or a Standard Endotracheal Tube (NCT NCT01263873)

NCT ID: NCT01263873

Last Updated: 2014-12-17

Results Overview

To measure the ease of intubation by time in seconds for ETT insertion. Time was measured in seconds and started when the anesthesia provider asked for the ETT and stopped once the ETT was placed through the glottis. The time was obtained from video recordings during the intubation by the principal investigator (PI).

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

60 participants

Primary outcome timeframe

Participants were followed for the duration of intubation, an average of 10 minutes

Results posted on

2014-12-17

Participant Flow

October, 2010 through January, 2011 in operative room.

Participant milestones

Participant milestones
Measure
Parker Flex Tip Endotracheal Tube
Parker Flex-Tip® which is a disposable polyvinyl chloride (PVC) Endotracheal tube with a flexible, tapered tip that is anatomically designed to the airway structures.
Mallinckrodt® Endotracheal Tube
Standard PVC Mallinckrodt® tube used throughout the world for intubating the trachea St. Louis, MO 63134.
Overall Study
STARTED
30
30
Overall Study
COMPLETED
29
29
Overall Study
NOT COMPLETED
1
1

Reasons for withdrawal

Reasons for withdrawal
Measure
Parker Flex Tip Endotracheal Tube
Parker Flex-Tip® which is a disposable polyvinyl chloride (PVC) Endotracheal tube with a flexible, tapered tip that is anatomically designed to the airway structures.
Mallinckrodt® Endotracheal Tube
Standard PVC Mallinckrodt® tube used throughout the world for intubating the trachea St. Louis, MO 63134.
Overall Study
One provider unable to complete numbers
1
1

Baseline Characteristics

Examining the Ease of Intubation Using the Parker Flex-Tip® or a Standard Endotracheal Tube

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Parker Flex Tip Endotracheal Tube
n=30 Participants
Parker Flex-Tip® which is a disposable polyvinyl chloride (PVC) Endotracheal tube with a flexible, tapered tip that is anatomically designed to the airway structures.
Mallinckrodt® Endotracheal Tube
n=30 Participants
Standard PVC Mallinckrodt® tube used throughout the world for intubating the trachea St. Louis, MO 63134.
Total
n=60 Participants
Total of all reporting groups
Age, Categorical
<=18 years
0 Participants
n=5 Participants
0 Participants
n=7 Participants
0 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
21 Participants
n=5 Participants
20 Participants
n=7 Participants
41 Participants
n=5 Participants
Age, Categorical
>=65 years
9 Participants
n=5 Participants
10 Participants
n=7 Participants
19 Participants
n=5 Participants
Age, Continuous
55 years
STANDARD_DEVIATION 14 • n=5 Participants
51 years
STANDARD_DEVIATION 19 • n=7 Participants
53 years
STANDARD_DEVIATION 16 • n=5 Participants
Sex: Female, Male
Female
18 Participants
n=5 Participants
15 Participants
n=7 Participants
33 Participants
n=5 Participants
Sex: Female, Male
Male
12 Participants
n=5 Participants
15 Participants
n=7 Participants
27 Participants
n=5 Participants
Region of Enrollment
United States
30 participants
n=5 Participants
30 participants
n=7 Participants
60 participants
n=5 Participants

PRIMARY outcome

Timeframe: Participants were followed for the duration of intubation, an average of 10 minutes

To measure the ease of intubation by time in seconds for ETT insertion. Time was measured in seconds and started when the anesthesia provider asked for the ETT and stopped once the ETT was placed through the glottis. The time was obtained from video recordings during the intubation by the principal investigator (PI).

Outcome measures

Outcome measures
Measure
Parker Flex Tip Endotracheal Tube
n=30 Participants
Parker Flex-Tip® which is a disposable polyvinyl chloride (PVC) Endotracheal tube with a flexible, tapered tip that is anatomically designed to the airway structures.
Mallinckrodt® Endotracheal Tube
n=30 Participants
Standard PVC Mallinckrodt® tube used throughout the world for intubating the trachea St. Louis, MO 63134.
Ease of Intubation, as Measured by Time in Seconds for ETT Insertion
10.8 Seconds
Standard Deviation 7.6
12.7 Seconds
Standard Deviation 7.3

PRIMARY outcome

Timeframe: Participants were followed for the duration of intubation, an average of 10 minutes

To measure the ease of intubation, once the airway structure was visualized with the GlideScope, the number of ETT redirections at the glottis to intubate the trachea was counted by video recordings by the PI.

Outcome measures

Outcome measures
Measure
Parker Flex Tip Endotracheal Tube
n=30 Participants
Parker Flex-Tip® which is a disposable polyvinyl chloride (PVC) Endotracheal tube with a flexible, tapered tip that is anatomically designed to the airway structures.
Mallinckrodt® Endotracheal Tube
n=30 Participants
Standard PVC Mallinckrodt® tube used throughout the world for intubating the trachea St. Louis, MO 63134.
Ease of Intubation, as Measured by Number of ETT Redirections
0.7 Number of redirections to place ETT
Standard Deviation 1.4
1.3 Number of redirections to place ETT
Standard Deviation 2.8

PRIMARY outcome

Timeframe: Participants were followed for the duration of intubation, an average of 10 minutes

To measure the ease of intubation, an ease of ETT insertion score was obtained by using a 100 millimeter visual analog scale done by the anesthesia provider doing the intubation. The score of 0 millimeters was the easiest intubation and a score of 100 millimeters was the hardest intubation done by that anesthesia provider.

Outcome measures

Outcome measures
Measure
Parker Flex Tip Endotracheal Tube
n=30 Participants
Parker Flex-Tip® which is a disposable polyvinyl chloride (PVC) Endotracheal tube with a flexible, tapered tip that is anatomically designed to the airway structures.
Mallinckrodt® Endotracheal Tube
n=30 Participants
Standard PVC Mallinckrodt® tube used throughout the world for intubating the trachea St. Louis, MO 63134.
Ease of Intubation, as Measured by an Ease of ETT Insertion Score.
12.7 Visual Analog Score in millimeters
Standard Deviation 12.4
17.8 Visual Analog Score in millimeters
Standard Deviation 19.9

Adverse Events

Parker Flex Tip Endotracheal Tube

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Mallinckrodt® Endotracheal Tube

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Brian Radesic

University Hospitals of Cleveland

Phone: 3309725175

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place