Trial Outcomes & Findings for Validation of the Stayhealthy BC1 Body Comp Analyzer (NCT NCT01209923)
NCT ID: NCT01209923
Last Updated: 2022-01-13
Results Overview
Percent body was compared between devices
Recruitment status
COMPLETED
Study phase
NA
Target enrollment
362 participants
Primary outcome timeframe
2 measures were assessed during a single visit
Results posted on
2022-01-13
Participant Flow
Participant milestones
| Measure |
Body Composition Testing
Body composition tested using bioelectrical impedance (BC1) and the DEXA or hydrostatic weighing methods.
BC1: Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
|
|---|---|
|
Overall Study
STARTED
|
362
|
|
Overall Study
COMPLETED
|
362
|
|
Overall Study
NOT COMPLETED
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Race and Ethnicity were not collected from any participant.
Baseline characteristics by cohort
| Measure |
Body Composition Testing
n=362 Participants
Body composition tested using bioelectrical impedance and the DEXA or hydrostatic weighing methods.
BC1: Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
|
|---|---|
|
Age, Categorical
<=18 years
|
115 Participants
n=362 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
237 Participants
n=362 Participants
|
|
Age, Categorical
>=65 years
|
10 Participants
n=362 Participants
|
|
Age, Continuous
|
45.7 years
STANDARD_DEVIATION 17.4 • n=362 Participants
|
|
Sex: Female, Male
Female
|
192 Participants
n=362 Participants
|
|
Sex: Female, Male
Male
|
170 Participants
n=362 Participants
|
|
Region of Enrollment
United States
|
360 participants
n=362 Participants
|
PRIMARY outcome
Timeframe: 2 measures were assessed during a single visitPopulation: 247 adults and 115 children
Percent body was compared between devices
Outcome measures
| Measure |
Stayhealthy BC1 Bioelectric Impedance Analyzer
n=362 Participants
Body composition tested using bioelectrical impedance and the DEXA or hydrostatic weighing methods.
BC1: Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
|
Reference Assessment
n=362 Participants
Body composition tested using bioelectrical impedance and the DEXA or hydrostatic weighing methods.
Dual-Energy X-Ray Absoptiometry assessment of body fat for adults or hydrostatic weighing assessment of body fat for children
|
|---|---|---|
|
Percent Body Fat
Women
|
32.8 percent body fat
Standard Deviation 9.1
|
33.4 percent body fat
Standard Deviation 9.6
|
|
Percent Body Fat
Men
|
20.3 percent body fat
Standard Deviation 5.3
|
20.4 percent body fat
Standard Deviation 5.6
|
|
Percent Body Fat
Children
|
18.4 percent body fat
Standard Deviation 8.4
|
18.8 percent body fat
Standard Deviation 8.3
|
Adverse Events
Body Composition Testing
Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place