Trial Outcomes & Findings for Validation of the Stayhealthy BC1 Body Comp Analyzer (NCT NCT01209923)

NCT ID: NCT01209923

Last Updated: 2022-01-13

Results Overview

Percent body was compared between devices

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

362 participants

Primary outcome timeframe

2 measures were assessed during a single visit

Results posted on

2022-01-13

Participant Flow

Participant milestones

Participant milestones
Measure
Body Composition Testing
Body composition tested using bioelectrical impedance (BC1) and the DEXA or hydrostatic weighing methods. BC1: Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
Overall Study
STARTED
362
Overall Study
COMPLETED
362
Overall Study
NOT COMPLETED
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Body Composition Testing
n=362 Participants
Body composition tested using bioelectrical impedance and the DEXA or hydrostatic weighing methods. BC1: Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
Age, Categorical
<=18 years
115 Participants
n=362 Participants
Age, Categorical
Between 18 and 65 years
237 Participants
n=362 Participants
Age, Categorical
>=65 years
10 Participants
n=362 Participants
Age, Continuous
45.7 years
STANDARD_DEVIATION 17.4 • n=362 Participants
Sex: Female, Male
Female
192 Participants
n=362 Participants
Sex: Female, Male
Male
170 Participants
n=362 Participants
Region of Enrollment
United States
360 participants
n=362 Participants

PRIMARY outcome

Timeframe: 2 measures were assessed during a single visit

Population: 247 adults and 115 children

Percent body was compared between devices

Outcome measures

Outcome measures
Measure
Stayhealthy BC1 Bioelectric Impedance Analyzer
n=362 Participants
Body composition tested using bioelectrical impedance and the DEXA or hydrostatic weighing methods. BC1: Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
Reference Assessment
n=362 Participants
Body composition tested using bioelectrical impedance and the DEXA or hydrostatic weighing methods. Dual-Energy X-Ray Absoptiometry assessment of body fat for adults or hydrostatic weighing assessment of body fat for children
Percent Body Fat
Women
32.8 percent body fat
Standard Deviation 9.1
33.4 percent body fat
Standard Deviation 9.6
Percent Body Fat
Men
20.3 percent body fat
Standard Deviation 5.3
20.4 percent body fat
Standard Deviation 5.6
Percent Body Fat
Children
18.4 percent body fat
Standard Deviation 8.4
18.8 percent body fat
Standard Deviation 8.3

Adverse Events

Body Composition Testing

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Edward Schroeder

University of Southern California

Phone: 323-442-2498

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place