Bedside Measurement of Ventilation With or Without a One-way Valve During Lung Lavage
NCT ID: NCT01143961
Last Updated: 2023-08-31
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
50 participants
INTERVENTIONAL
2010-06-30
2011-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
1. To use a non-invasive imaging technique known as electrical impedance tomography (EIT) to measure the amount of lung collapse during an NBL. Half of the patients in the study will have a one-way adapter valve connected to the breathing circuit. This adapter is designed to make the insertion of a suction catheter easier and prevent the loss of gas.
2. Look at which region of the lung the sample is being collected from as the suction tube used to take the samples may pass into either the left or right lung.
EIT is a simple non-invasive technique which has been in use for many years. It uses pairs of electrodes around the chest through which imperceptible currents are passed. A computer shows an image of which parts of the lungs have the most or least air in them. This has the advantage over other imaging techniques in critical care that it does not use radiation and gives a real time picture at the bedside of the variations in ventilation throughout the lungs.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Respiratory Mechanics Measurement of Ventilated Patients Through Low-frequency Oscillometry Technique
NCT06483529
Netosis in Determination of Respiratory Infection Severity
NCT04318691
Assessment of the Diagnostic Capacity of the Mini-broncho Alveolar Lavage Performed Through a Suction Catheter
NCT00763620
May Noninvasive Mechanical Ventilation (NIV) and/or Continuous Positive Airway Pressure (CPAP) Increase the Bronchoalveolar Lavage (BAL) Salvage in Patients With Pulmonary Diseases?
NCT05631132
Fiberoptic Bronchoscopy and Bronchoalveolar Lavage in Critically Ill Ventilated Patients
NCT04502368
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The second objective of the study is to locate the placement of catheter tips during the performance of NBLs, using electrical impedance tomography.
Equipment: A sixteen-electrode single frequency electrical impedance tomography device with on-line image analysis (CareFusion). One-way adapter valves which attach to the catheter mount (CareFusion).
Study Population: Critically ill adult patients admitted to the intensive care unit at the University Hospital of Wales Cardiff in whom NBLs are performed as part of their routine care.
Recruitment: All patients satisfying inclusion and exclusion criteria, admitted to the adult ICU at the University Hospital of Wales from the start date of the study will be considered eligible for recruitment. Patients identified by the duty consultant will be notified to the research team. Patients will be randomly allocated to have NBLs performed with or without the one-way valve attached to the catheter mount.
Since this is an observational pilot study a minimum of fifty patients will be identified.
Interventions: The second cohort of patients will have NBLs performed with the one-way adapter connected to the catheter mount, otherwise there will be no change will be made to the normal standard of care.
Method: Following cleaning of the skin with alcohol wipes sixteen ECG electrodes will be placed equidistantly from one another midway between sternum and umbilicus. A reference electrode will be placed on the right hand side of the chest. NBLs will be undertaken according to routine standards of care. In brief, this involves pre-oxygenating the patient, and inserting a suction catheter attached to a 20ml saline filled syringe through the catheter mount (25 patients) or adapter with one-way valve connected to the catheter mount (25 patients) until resistance is met. The saline is instilled and then slowly withdrawn to obtain a sample. Since saline is conductive, instillation results in a change in local impedance which is detected by the array of electrodes. The image obtained will identify into which region of the lung the catheter is placed. Any changes in the gas content of lung (due to loss of PEEP) will be manifest as changes in lung impedance and reflects a change in regional ventilation. NBLs are undertaken when clinically indicated and patients may have more than one recoding undertaken up to a maximum of three times.
Collection of other data: Baseline demographics of patients will be recorded, including age, sex, APACHE II score, co-morbidities, diagnosis, days from hospital admission. Ventilator settings - mode, inspired oxygen fraction, tidal and minute ventilation, compliance, PEEP and mean airway pressure will be recorded.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
NBL with one-way valve
NBL performed with one-way valve in ventilator circuit during procedure
CSC100 - Verso airway access adapter CareFusion
Following randomisation patients will have a one-way valve inserted into the ventilator circuit (CSC100 - Verso airway access adapter CareFusion) prior to a non-directed bronchoalveolar lavage (NBL) being performed. Changes in regional ventilation will be recorded by electrical impedance tomography during the NBL. Recordings of ventilation will take place for upto four hours. One-way valve will stay in place until ventilator circuit is changed.
Standard NBL
Performance of standard NBL with recording of changes in regional ventilation by electrical impedance tomography
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CSC100 - Verso airway access adapter CareFusion
Following randomisation patients will have a one-way valve inserted into the ventilator circuit (CSC100 - Verso airway access adapter CareFusion) prior to a non-directed bronchoalveolar lavage (NBL) being performed. Changes in regional ventilation will be recorded by electrical impedance tomography during the NBL. Recordings of ventilation will take place for upto four hours. One-way valve will stay in place until ventilator circuit is changed.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients in whom an NBL is indicated as part of standard treatment
* Patient on mechanical ventilation with PEEP
Exclusion Criteria
* Age \<18 years
* Patient not on mechanical ventilation with PEEP
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cardiff and Vale University Health Board
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Matt P Wise, DPhil
Role: PRINCIPAL_INVESTIGATOR
University Hospital of Wales Cardiff & Vale University Health Board
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Adult Critical Care, University Hospital of Wales
Cardiff, South Glamorgan, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
09/MRE09/54
Identifier Type: -
Identifier Source: org_study_id
More Related Trials