Trial Outcomes & Findings for Comparative Study of Implant Surfaces to Enhance Stabilization in Patients With Type 2 Diabetes (NCT NCT01142297)

NCT ID: NCT01142297

Last Updated: 2018-01-03

Results Overview

resonance frequency analysis employed to determine implant stability quotient on a 1-100 point scale with 100 representing the greatest stability.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

24 participants

Primary outcome timeframe

4 months

Results posted on

2018-01-03

Participant Flow

Participant milestones

Participant milestones
Measure
Dental Implant
standard SLA surface and chemically-modified surface implant
Overall Study
STARTED
24
Overall Study
COMPLETED
18
Overall Study
NOT COMPLETED
6

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Comparative Study of Implant Surfaces to Enhance Stabilization in Patients With Type 2 Diabetes

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Dental Implant
n=24 Participants
standard SLA surface and chemically modified surface dental implant : standard SLA surface and modified dental implant : chemically modified surface
Age, Categorical
<=18 years
0 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
20 Participants
n=5 Participants
Age, Categorical
>=65 years
4 Participants
n=5 Participants
Age, Continuous
57.3 years
STANDARD_DEVIATION 9.5 • n=5 Participants
Sex: Female, Male
Female
15 Participants
n=5 Participants
Sex: Female, Male
Male
9 Participants
n=5 Participants
Region of Enrollment
United States
24 participants
n=5 Participants

PRIMARY outcome

Timeframe: 4 months

resonance frequency analysis employed to determine implant stability quotient on a 1-100 point scale with 100 representing the greatest stability.

Outcome measures

Outcome measures
Measure
SLA Minimum ISQ HbA1c<9.5
n=24 Participants
standard SLA surface dental implant : standard SLA surface
Modified SLA Minimum ISQ HbA1c<9.5
n=24 Participants
chemically modified surface modified dental implant : chemically modified surface
Implant Stability Quotient (ISQ)
61.9 units on a scale
Standard Error 5.6
61.3 units on a scale
Standard Error 3.2

SECONDARY outcome

Timeframe: 1 year

Population: Data were not collected

Outcome measures

Outcome data not reported

Adverse Events

Dental Implant

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Modified Dental Implant

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Thomas W. Oates

University of Texas Health Science Center at San Antonio

Phone: 210-567-3590

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place