Computed Tomography Enterography (CTE) Versus Capsule Endoscopy for Overt, Obscure Gastrointestinal (GI) Bleeding
NCT ID: NCT01114295
Last Updated: 2013-08-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2010-03-31
2012-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Obscure gastrointestinal bleeding (OGIB) refers to bleeding undiagnosed by upper endoscopy and colonoscopy. In 40-70% of cases of OGIB, a bleeding lesion is localizable to the small bowel. In OGIB, capsule endoscopy (CE) has a diagnostic yield of 40-80%, and has demonstrated diagnostic superiority to push enteroscopy, barium studies, angiography, CT angiography, and routine abdominal CT scan. When CE is non-diagnostic, however, the subsequent diagnostic algorithm is not well-defined. There is currently no established role for cross-sectional imaging for this indication. CT enterography (CTE) combines the spatial and temporal resolution of CT with an orally administered neutral enteric contrast material that permits detailed visualization of the small bowel. Unlike other imaging modalities such as nuclear medicine techniques and catheter angiography, CT is less labor-intensive, more readily available, and provides precise anatomic localization. A novel OGIB-protocol available at Brigham and Women's Hospital for CTE utilizes a dual-phase, dual energy technique that obtains images at two time points to better identify active bleeding in the mesentery. We, the investigators, plan to prospectively study an algorithm that employs CTE and compare to capsule endoscopy to investigate the effectiveness of both modalities and to evaluate the potential role of CTE in OGIB.
The goal of our study is to determine observationally the contribution of both CE and the new protocol for CTE to the evaluation and management of overt obscure GI bleeding and accordingly revise the clinical algorithm.
We hypothesize that CTE will be as or more effective than CE at identifying culprit lesions in overt, obscure gastrointestinal bleeding.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Overt Obscure Gastrointestinal Bleeders
The only cohort in this study are those patients identified as having overt, obscure gastrointestinal bleeding who will then undergo CE or CTE.
Capsule Endoscopy
Prior to the test, patients will be on a clear liquid diet for 24 hours and will have undergone an overnight fast. If a clear liquid diet is not possible, some patients may undergo a bowel preparation the day before the procedure. On the morning of the test, patients will swallow a video capsule with water. Clear liquids will be permitted after 2 hours, and a light meal permitted 4 hours after swallowing the capsule, if appropriate. No medications will be allowed 2 hours before the procedure and drugs that can delay gastric emptying will be avoided until the study is complete. At 8 hours after ingestion, the sensor array and recorder/battery belt pack will be disconnected and the data will be downloaded onto a computer equipped with software for image viewing. Images are sent through 8 skin electrodes to the recorder, stored and viewed on a RAPID workstation. At the end of the recording, the video is transferred to a computer for analysis.
CT Enterography
CT enterography at the Brigham and Women's hospital is performed by using intravenous iodinated contrast material (Ultravist 300) and a neutral oral-enteric contrast material containing methylcellulose (Volumen). During scanning, 150 mL of nonionic intravenous contrast medium will be administered at a rate of 3mL/sec and the imaging conducted 40 and 70 seconds after the administration of the intravenous contrast medium. All imaging will be performed on a Dual-Energy multi-detector row CT scanner, Somatom Definition (Siemens Healthcare, Forcheim, Germany). Two independent X-ray tube/detector system will be used for image acquisition. One tube operates at 140 kV and the other at 80 kV . Slice collimation will be 0.6 mm and images reconstructed at 3 mm thickness with 3 mm reconstruction intervals. Coronal and sagittal images will be reconstructed at 3 mm thickness with 3 mm increments. Images will be reviewed by a radiologist experienced in the interpretation of CT enterography.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Capsule Endoscopy
Prior to the test, patients will be on a clear liquid diet for 24 hours and will have undergone an overnight fast. If a clear liquid diet is not possible, some patients may undergo a bowel preparation the day before the procedure. On the morning of the test, patients will swallow a video capsule with water. Clear liquids will be permitted after 2 hours, and a light meal permitted 4 hours after swallowing the capsule, if appropriate. No medications will be allowed 2 hours before the procedure and drugs that can delay gastric emptying will be avoided until the study is complete. At 8 hours after ingestion, the sensor array and recorder/battery belt pack will be disconnected and the data will be downloaded onto a computer equipped with software for image viewing. Images are sent through 8 skin electrodes to the recorder, stored and viewed on a RAPID workstation. At the end of the recording, the video is transferred to a computer for analysis.
CT Enterography
CT enterography at the Brigham and Women's hospital is performed by using intravenous iodinated contrast material (Ultravist 300) and a neutral oral-enteric contrast material containing methylcellulose (Volumen). During scanning, 150 mL of nonionic intravenous contrast medium will be administered at a rate of 3mL/sec and the imaging conducted 40 and 70 seconds after the administration of the intravenous contrast medium. All imaging will be performed on a Dual-Energy multi-detector row CT scanner, Somatom Definition (Siemens Healthcare, Forcheim, Germany). Two independent X-ray tube/detector system will be used for image acquisition. One tube operates at 140 kV and the other at 80 kV . Slice collimation will be 0.6 mm and images reconstructed at 3 mm thickness with 3 mm reconstruction intervals. Coronal and sagittal images will be reconstructed at 3 mm thickness with 3 mm increments. Images will be reviewed by a radiologist experienced in the interpretation of CT enterography.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Allergy to iodinated intravenous (IV) contrast media
* Swallowing difficulties
* Known small bowel strictures
* Suspected bowel obstruction
* Under the age of 18
* Unable to give consent
* Currently pregnant
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Brigham and Women's Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
John Robinson Saltzman, MD
Director of Endoscopy
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
John Saltzman, MD
Role: PRINCIPAL_INVESTIGATOR
Brigham and Women's Hospital
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CTE vs Capsule 2010
Identifier Type: -
Identifier Source: org_study_id