Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
50 participants
INTERVENTIONAL
2010-04-30
2011-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Video capsule endoscopy (VCE) is an important tool in the diagnostic management of several gastrointestinal (GI) disorders. Taking a video while passing the GI tract, VCE is the only technique providing image information of the whole small bowel. It is a comfortable and safe procedure; complications due to capsule retention are rare \[1\]. The main disadvantage of VCE is made up by its only dependence on macroscopic information. Therefore it can not be reliably used for the detection of disorders that need histological confirmation. However, lots of macroscopic pathologies can be diagnosed or excluded by VCE. Above all, obscure digestive bleeding (ODB) has become the main indication for the use of VCE \[2\].
Independent from the type of bowel preparation used, the ileocaecal transit cannot be visualized in up to 20 percent of VCE examinations, which means the loss of diagnostic information of the last intestinal parts \[3\]. Risk factors of such incomplete VCE include previous small-bowel surgery, hospitalization, moderate or poor bowel cleansing and a gastric transit time longer than 45 minutes \[4\]. Especially in the latter case, the success of the examination is determined by the battery life expectancy of the capsule technology used \[5\].
The new MiroCam®, a brand of IntroMedic®, is advertised to have a longer battery life expectancy than competitive products throughout the market. To prove this pronouncement, a pilot-study of 16 patients was presented by He Man Kim at the UEGW 2008, comparing MiroCam® to Given®'s PillCam® by sequential application of both capsules. Although the battery life expectancy of MiroCam® was significantly higher, there was no significant difference in the diagnostic yield of both products \[6\]. Currently a similar comparison study between MiroCam® and Pill Cam® is ongoing in France, involving a higher amount of patients \[unpublished data\].
Study Aims
In this prospective study we want to compare IntroMedic®'s MiroCam® to Olympus® Enteropro EndoCapsule® which was so far routinely used at our department. We want to investigate whether one of the two products provides superior diagnostic information about the small bowel. The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration. The secondary end point will be the number of pathologies detected by each capsule. If there will be a significant difference between the two tested products, preferred usage of the superior product may improve the diagnostic yield of future examinations by avoiding incomplete video registration of the small bowel.
Study Design
Prospective Study without randomisation or blinding
Study Population
Patients transferred to our unit to undergo video capsule endoscopy because of
* Obscure digestive bleeding (ODB)
* Chronic anaemia of unknown origin
* Chronic diarrhoea
Exclusion criteria:
* Patients age below 18 years
* Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility
* Refusal to participate in the study
Methods
Our investigation will be performed at the Medical University of Vienna, department of medicine III, clinical division of gastroenterology and hepatology. Patient recruitment will start on the 1st of January 2010. The study will last for six month. The number of patients included within this period will be around 50, based on the current amount of VCE examinations performed at our department.
All patients who fulfil the listed inclusion criteria, will receive the patient information form of this study together with the routine informed consent form of VCE. Potentially occurring questions about the course of the examination, data acquisition and processing in context of the study will be answered by medical professionals.
As routine preparation for VCE, patients will receive 2 litres of washout solution on the previous day of their examination. At the day of the procedure fasting is required. The patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later - to our knowledge the first capsule will have already passed the gastro-duodenal transit at this time. The two capsules used in our investigation are the already mentioned MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. After both capsules have been swallowed, fasting has to be continued for four hours to prevent image interference of VCE.
Risk/Benefit Assessment
The safety of both products used within our investigation was already proved in former clinical trials \[7, 8\]. For the patients enrolled in our study the potentially higher risk of complications will be made up for the expected increase of diagnostic yield that will be implicated by the evaluation of two different bowel videos. The only notable discomfort for patients participating in our investigation will be caused by the rather high amount of adhesive electrodes necessary for both capsules. There should not be any interference of the two video signals as already shown in former investigations \[6,9\].
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
SINGLE_GROUP
DIAGNOSTIC
SINGLE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Video capsule endoscopy (VCE)
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
MiroCam
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
Enteropro EndoCapsule
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Obscure digestive bleeding (ODB)
* Chronic anaemia of unknown origin
* Chronic diarrhoea
Exclusion Criteria
* Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility
* Refusal to participate in the study
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medical University of Vienna
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Werner Dolak, MD
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Andreas Puespoek, MD
Role: STUDY_DIRECTOR
Medical University of Vienna
Werner Dolak, MD
Role: PRINCIPAL_INVESTIGATOR
Medical University of Vienna
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Medical University of Vienna, Department of Medicine III., Clinical Division of Gastroenterology and Hepatology
Vienna, , Austria
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Munoz-Navas M. Capsule endoscopy. World J Gastroenterol. 2009 Apr 7;15(13):1584-6. doi: 10.3748/wjg.15.1584.
Nakamura T, Terano A. Capsule endoscopy: past, present, and future. J Gastroenterol. 2008;43(2):93-9. doi: 10.1007/s00535-007-2153-6. Epub 2008 Feb 29.
Kalantzis C, Triantafyllou K, Papadopoulos AA, Alexandrakis G, Rokkas T, Kalantzis N, Ladas SD. Effect of three bowel preparations on video-capsule endoscopy gastric and small-bowel transit time and completeness of the examination. Scand J Gastroenterol. 2007 Sep;42(9):1120-6. doi: 10.1080/00365520701251601.
Westerhof J, Weersma RK, Koornstra JJ. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009 Jan;69(1):74-80. doi: 10.1016/j.gie.2008.04.034. Epub 2008 Aug 8.
Sanchez-Yague A. Risk factors for incomplete small-bowel capsule endoscopy: should capsule retention be considered independently? Gastrointest Endosc. 2009 Oct;70(4):820; author reply 820. doi: 10.1016/j.gie.2009.02.018. No abstract available.
He Man Kim. Sequential capsule endoscopy of two different capsule endoscopes, MiroCam and Pillcam SB1, without interference: a pilot study. UEGW Oct 21, 2008.
Bang S, Park JY, Jeong S, Kim YH, Shim HB, Kim TS, Lee DH, Song SY. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc. 2009 Feb;69(2):253-9. doi: 10.1016/j.gie.2008.04.033. Epub 2008 Jul 21.
Gheorghe C, Iacob R, Bancila I. Olympus capsule endoscopy for small bowel examination. J Gastrointestin Liver Dis. 2007 Sep;16(3):309-13.
Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, Gostout CJ, Rajan E, Mergener K, Foley A, Lee M, Bhattacharya K. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008 Sep;68(3):487-94. doi: 10.1016/j.gie.2007.12.037. Epub 2008 Apr 14.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
EK 961/2009
Identifier Type: -
Identifier Source: org_study_id