Randomized Evaluation of Sirolimus-eluting Versus Everolimus-eluting Stent Trial

NCT ID: NCT01035450

Last Updated: 2015-12-10

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE4

Total Enrollment

3206 participants

Study Classification

INTERVENTIONAL

Study Start Date

2010-02-28

Study Completion Date

2014-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to evaluate whether the newly-approved everolimus-eluting stent is not inferior to the sirolimus-eluting stent in terms of the rate of target-lesion revascularization at 1-year and death or myocardial infarction at 3-year after stent implantation in the real world clinical practice.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Sirolimus-eluting stent is the most widely used coronary drug-eluting stent in Japan. Everolimus-eluting stent is a new coronary drug-eluting stent, which is going to be approved in the first quarter of 2010 by the Japanese Ministry of Health, Labor and Welfare. It has recently been reported that everolimus-eluting stent had lower rate of target-lesion revascularization and stent thrombosis at 1 year as compared with paclitaxel-eluting stent. However, trial results comparing everolimus-eluting stent with sirolimus-eluting stent are largely unknown. The purpose of this study is to evaluate whether the newly-approved everolimus-eluting stent is not inferior to the sirolimus-eluting stent in terms of the rate of target-lesion revascularization at 1-year and death or myocardial infarction at 3-year after stent implantation in the real world clinical practice. The design of this study is all-comer design enrolling patients scheduled for percutaneous coronary intervention using drug-eluting stents without any exclusion criteria.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Coronary stent

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Everolimus-eluting stent

Group Type EXPERIMENTAL

Everolimus-eluting stent

Intervention Type DEVICE

Everolimus-eluting stent

Sirolimus-eluting stent

Group Type ACTIVE_COMPARATOR

Sirolimus-eluting stent

Intervention Type DEVICE

Sirolimus-eluting stent

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Everolimus-eluting stent

Everolimus-eluting stent

Intervention Type DEVICE

Sirolimus-eluting stent

Sirolimus-eluting stent

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients scheduled for percutaneous coronary intervention using drug-eluting stents

Exclusion Criteria

* None
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Takeshi Morimoto

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Takeshi Morimoto

Professor

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Takeshi Kimura, MD

Role: PRINCIPAL_INVESTIGATOR

Professor of Medicine, Department of Cardiovascular Medicine, Kyoto University Graduate School of Medicine

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Division of Cardiology, Kyoto University Hospital

Kyoto, Kyoto, Japan

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Japan

References

Explore related publications, articles, or registry entries linked to this study.

Shiomi H, Kozuma K, Morimoto T, Kadota K, Tanabe K, Morino Y, Akasaka T, Abe M, Takeji Y, Suwa S, Ito Y, Kobayashi M, Dai K, Nakao K, Tarutani Y, Taniguchi R, Nishikawa H, Yamamoto Y, Nakagawa Y, Ando K, Kobayashi K, Kawai K, Hibi K, Kimura T; RESET Investigators. 7-Year Outcomes of a Randomized Trial Comparing the First-Generation Sirolimus-Eluting Stent Versus the New-Generation Everolimus-Eluting Stent: The RESET Trial. JACC Cardiovasc Interv. 2019 Apr 8;12(7):637-647. doi: 10.1016/j.jcin.2019.01.234.

Reference Type DERIVED
PMID: 30947938 (View on PubMed)

Ito S, Watanabe H, Morimoto T, Yoshikawa Y, Shiomi H, Shizuta S, Ono K, Yamaji K, Soga Y, Hyodo M, Shirai S, Ando K, Horiuchi H, Kimura T. Impact of Baseline Thrombocytopenia on Bleeding and Mortality After Percutaneous Coronary Intervention. Am J Cardiol. 2018 Jun 1;121(11):1304-1314. doi: 10.1016/j.amjcard.2018.02.010. Epub 2018 Mar 1.

Reference Type DERIVED
PMID: 29628128 (View on PubMed)

Watanabe H, Morimoto T, Shiomi H, Yoshikawa Y, Kato T, Saito N, Shizuta S, Ono K, Yamaji K, Ando K, Kaji S, Furukawa Y, Akao M, Ishikawa T, Tamura T, Yamamoto Y, Muramatsu T, Suwa S, Nakagawa Y, Kadota K, Takatsu Y, Nishikawa H, Hiasa Y, Hayashi Y, Miyazaki S, Kimura T. Mortality impact of post-discharge myocardial infarction size after percutaneous coronary intervention: a patient-level pooled analysis from the 4 large-scale Japanese studies. Cardiovasc Interv Ther. 2019 Jan;34(1):47-58. doi: 10.1007/s12928-018-0517-x. Epub 2018 Mar 5.

Reference Type DERIVED
PMID: 29508236 (View on PubMed)

Shiomi H, Kozuma K, Morimoto T, Igarashi K, Kadota K, Tanabe K, Morino Y, Akasaka T, Abe M, Suwa S, Muramatsu T, Kobayashi M, Dai K, Nakao K, Uematsu M, Tarutani Y, Fujii K, Simonton CA, Kimura T; RESET Investigators. Long-term clinical outcomes after everolimus- and sirolimus-eluting coronary stent implantation: final 3-year follow-up of the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial. Circ Cardiovasc Interv. 2014 Jun;7(3):343-54. doi: 10.1161/CIRCINTERVENTIONS.113.001322. Epub 2014 May 6.

Reference Type DERIVED
PMID: 24803436 (View on PubMed)

Kozuma K, Kimura T, Kadota K, Suwa S, Kimura K, Iwabuchi M, Kawai K, Miyazawa A, Kawamura M, Nakao K, Asano R, Yamamoto T, Suzuki N, Aoki J, Kyono H, Nakazawa G, Tanabe K, Morino Y, Igarashi K. Angiographic findings of everolimus-eluting as compared to sirolimus-eluting stents: angiographic sub-study from the Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial (RESET). Cardiovasc Interv Ther. 2013 Oct;28(4):344-51. doi: 10.1007/s12928-013-0179-7. Epub 2013 Apr 23.

Reference Type DERIVED
PMID: 23608784 (View on PubMed)

Kimura T, Morimoto T, Natsuaki M, Shiomi H, Igarashi K, Kadota K, Tanabe K, Morino Y, Akasaka T, Takatsu Y, Nishikawa H, Yamamoto Y, Nakagawa Y, Hayashi Y, Iwabuchi M, Umeda H, Kawai K, Okada H, Kimura K, Simonton CA, Kozuma K; RESET Investigators. Comparison of everolimus-eluting and sirolimus-eluting coronary stents: 1-year outcomes from the Randomized Evaluation of Sirolimus-eluting Versus Everolimus-eluting stent Trial (RESET). Circulation. 2012 Sep 4;126(10):1225-36. doi: 10.1161/CIRCULATIONAHA.112.104059. Epub 2012 Jul 23.

Reference Type DERIVED
PMID: 22824435 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

C338

Identifier Type: -

Identifier Source: org_study_id