Oral Appliance Therapy in Obstructive Sleep Apnea

NCT ID: NCT00950495

Last Updated: 2014-12-25

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

64 participants

Study Classification

INTERVENTIONAL

Study Start Date

2003-10-31

Study Completion Date

2009-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The aim of the study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure(nCPAP) and of an intra-oral placebo device in obstructive sleep apnea (OSA) patients. The hypothesis for this study was that both MAD therapy and nCPAP therapy have similar, better treatment effects than placebo therapy in OSA. The study was performed according to the CONSORT (consolidated standards of reporting trials) statement (Altman et al., 2001), employing a parallel-group, randomized, placebo-controlled trial design.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Setting and participants:

Eligible OSA patients, living in the greater Amsterdam area, were referred to the Slotervaart Medical Center by their family physician. All patients underwent a thorough medical examination, including a full polysomnographic (PSG) recording, at the departments of Neurology, Pulmonary Medicine, and ENT, as well as a thorough dental examination at the Department of Oral Kinesiology of ACTA. OSA patients were invited for participation in this study when they fulfilled the inclusion criteria and exclusion criteria.

Randomisation and allocation:

After written informed consent was obtained, the patients were randomly allocated to one of three therapy groups (MAD, nCPAP, or placebo; see below). To ensure that the groups were of approx. the same size, block randomisation was used. Block sizes were 6, 12, and 18; sizes were randomly varied. The allocation sequence was automatically generated and subsequently concealed by an independent co-worker, who kept a paper copy in a lockable drawer. Sealed opaque envelopes were used to conceal the allocation from the principal investigator.

Interventions and blinding:

Three forms of therapy interventions were used in this parallel-group study. First, an individually fabricated MAD with an adjustable protrusive mandibular position at a constant vertical dimension was used. Second, nCPAP of the REMstar Pro system was used (Respironics, Herrsching, Germany). Third, a thin (\< 1 mm), hard acrylic-resin palatal splint with only a partial palatal coverage was used as a placebo.

Patients were blinded to the nature of the assigned therapy (placebo or active). After evaluating the therapy, all patients were asked if they were of the opinion that they had received an active or placebo treatment. Blinding of the analyst was ascertained by assigning codes to data sets and by analyzing these sets in random blocks.

Procedure:

From all patients, two full polysomnographic (PSG) recordings were obtained in the sleep laboratory of the Slotervaart Medical Center, using Siesta hardware and Pro-Fusion software (Compumedics, Abbotsford, Australia): one before therapy assignment (baseline PSG) and one after 6 ± 2 months (mean ± SD) of treatment (therapy evaluation PSG). For the MAD and nCPAP groups, the third and fourth PSG recordings for therapy evaluation were performed 6 months and one year after the first therapy evaluation (long-term follow-up). The primary and secondary outcome measures were obtained at baseline and at therapy evaluations.

The MAD and nCPAP were titrated before the start of the treatment. The titration of the nCPAP was performed during a third sleep laboratory examination. The pressure was increased in incremental steps of 1 cm H2O/h, until respiratory disturbances and respiration-related arousals were reduced to ≤ 5/h, and snoring was minimized.

For the titration of the MAD, four ambulatory PSG recordings were obtained at regular intervals, using Monet hardware and Rembrandt Software (Medcare Automation B.V., Amsterdam, The Netherlands). The most effective protrusion position of the MAD (i.e., the mandibular position that yielded the lowest AHI value) was chosen from among four randomly offered positions (viz., 0%, 25%, 50%, and 75% of the maximum protrusion).

For the placebo group, the study procedure was made equally intense as that for the MAD group by making four ambulatory PSG recordings at regular intervals as well.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Obstructive Sleep Apnea

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Parallel design Oral appliance Mandibular advancement device Continuous positive airway pressure Placebo Therapy Side-effects Compliance

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Investigators

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Mandibular advancement device (MAD)

an MAD is placed in the mouth prior to sleep. After waking up in the morning, the appliance is removed.

Group Type ACTIVE_COMPARATOR

Mandibular Advancement Device (MAD)

Intervention Type DEVICE

This oral appliance keeps the mandible and the tongue in a protruded position. This results in an upper respiratory tract widening and/or reduced collapsibility of the upper airway, thereby preventing the upper airway collapse during sleep.

nasal CPAP

The device is turned on, and the nasal mask is placed on the nose prior to sleep. After waking up in the morning, the device is turned off and the mask is removed

Group Type ACTIVE_COMPARATOR

nasal CPAP

Intervention Type DEVICE

The CPAP machine delivers a stream of compressed air via a hose to a nose mask, splinting the airway (keeping it open under air pressure) so that unobstructed breathing becomes possible, reducing and/or preventing apneas and hypopneas

placebo

the placebo appliance is placed in the mouth prior to sleep. After waking up in the morning, the appliance is removed.

Group Type PLACEBO_COMPARATOR

placebo

Intervention Type DEVICE

as a placebo, a thin (\< 1 mm), hard acrylic-resin palatal splint with only a partial palatal coverage was used

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Mandibular Advancement Device (MAD)

This oral appliance keeps the mandible and the tongue in a protruded position. This results in an upper respiratory tract widening and/or reduced collapsibility of the upper airway, thereby preventing the upper airway collapse during sleep.

Intervention Type DEVICE

nasal CPAP

The CPAP machine delivers a stream of compressed air via a hose to a nose mask, splinting the airway (keeping it open under air pressure) so that unobstructed breathing becomes possible, reducing and/or preventing apneas and hypopneas

Intervention Type DEVICE

placebo

as a placebo, a thin (\< 1 mm), hard acrylic-resin palatal splint with only a partial palatal coverage was used

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

mandibular repositioning appliance mandibular advancement appliance mandibular repositioning device mandibular repositioning splint mandibular advancement splint oral appliance

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* age \> 18 years
* apnea-hypopnea index (AHI) between 5 and 45 events per hour

Exclusion Criteria

* evidence of respiratory/ sleep disorders other than obstructive sleep apnea
* a body mass index (BMI) \> 40
* medication usage that could influence respiration or sleep
* periodic limb movement disorder
* previous treatment with CPAP or MAD
* reversible morphological upper airway abnormalities (e.g., enlarged tonsils)
* temporomandibular disorders (based on a functional examination of the masticatory system)
* untreated periodontal problems
* dental pain
* lack of retention possibilities for a mandibular advancement device or a placebo appliance
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

VU University of Amsterdam

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ghizlane Aarab

Dr.

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ghizlane Aarab, DDS

Role: PRINCIPAL_INVESTIGATOR

Academic Centre for Dentistry Amsterdam (ACTA), Research Institute Move, University of Amsterdam and VU University Amsterdam

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Academic Centre for Dentistry Amsterdam (ACTA), Research Institute Move, University of Amsterdam and VU University Amsterdam

Amsterdam, , Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

References

Explore related publications, articles, or registry entries linked to this study.

Aarab G, Lobbezoo F, Hamburger HL, Naeije M. Effects of an oral appliance with different mandibular protrusion positions at a constant vertical dimension on obstructive sleep apnea. Clin Oral Investig. 2010 Jun;14(3):339-45. doi: 10.1007/s00784-009-0298-9. Epub 2009 Jun 18.

Reference Type RESULT
PMID: 19536571 (View on PubMed)

Aarab G, Lobbezoo F, Hamburger HL, Naeije M. Variability in the apnea-hypopnea index and its consequences for diagnosis and therapy evaluation. Respiration. 2009;77(1):32-7. doi: 10.1159/000167790. Epub 2008 Oct 29.

Reference Type RESULT
PMID: 18957843 (View on PubMed)

Aarab G, Lobbezoo F, Wicks DJ, Hamburger HL, Naeije M. Short-term effects of a mandibular advancement device on obstructive sleep apnoea: an open-label pilot trial. J Oral Rehabil. 2005 Aug;32(8):564-70. doi: 10.1111/j.1365-2842.2005.01467.x.

Reference Type RESULT
PMID: 16011634 (View on PubMed)

Aarab G, Lobbezoo F, Hamburger HL, Naeije M. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnea: a randomized, placebo-controlled trial. Respiration. 2011;81(5):411-9. doi: 10.1159/000319595. Epub 2010 Oct 20.

Reference Type RESULT
PMID: 20962502 (View on PubMed)

Aarab G, Lobbezoo F, Heymans MW, Hamburger HL, Naeije M. Long-term follow-up of a randomized controlled trial of oral appliance therapy in obstructive sleep apnea. Respiration. 2011;82(2):162-8. doi: 10.1159/000324580. Epub 2011 Mar 31.

Reference Type RESULT
PMID: 21454959 (View on PubMed)

Nikolopoulou M, Naeije M, Aarab G, Hamburger HL, Visscher CM, Lobbezoo F. The effect of raising the bite without mandibular protrusion on obstructive sleep apnoea. J Oral Rehabil. 2011 Sep;38(9):643-7. doi: 10.1111/j.1365-2842.2011.02221.x. Epub 2011 Apr 5.

Reference Type RESULT
PMID: 21463349 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

U/1731/0326

Identifier Type: -

Identifier Source: org_study_id