Incisional Vacuum Assisted Closure (IVAC) Device and Its Effect on Implanted Bone Morphogenic Protein (BMP-2)

NCT ID: NCT00829621

Last Updated: 2016-11-07

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2008-12-31

Study Completion Date

2013-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

People who have been scheduled for surgery using Bone Morphogenic Protein (called BMP-2) and an incisional vacuum assisted closure device (called IVAC) will be asked to join this study.

The purpose of this study is to see if using the IVAC device removes BMP-2 from the wound. BMP-2 is a protein used by the body to increase bone healing, decrease the need for additional surgery, and reduce infection rates.

The IVAC is a device that involves a foam dressing secured with an adhesive drape to make an airtight seal over a surgical incision. Tubing runs from the foam dressing to a device that uses gentle suction to drain fluid out (like a vacuum). The IVAC stays on for 48-72 hours depending on amount of drainage. The IVAC by itself helps reduce wound swelling and complications (such as infection).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

It is hypothesized that the negative pressure associated with an IVAC is not sufficient to remove BMP-2 from a surgical wound.

BMP-2 is commonly used in open tibia fractures at the time of definitive wound closure, and these wounds are prone to increased swelling and wound complications. The recent observation that IVAC decreases wound edema and increases oxygenation has led to their use in such cases. Used in conjunction, it is entirely possible that the negative pressure exerted by the IVAC can remove BMP-2 from surgical site and therefore decreases the effectiveness of BMP-2. We seek to determine if BMP-2 is present in effluent from the IVAC. If in this study the hypothesis is found to be wrong, and BMP-2 is found within the IVAC effluent, we are prepared to proceed with a follow-up study to quantify the BMP-2 removed by the IVAC.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Fractures, Closed

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

BMP-2 Incisional Vacuum Assisted Closure (IVAC)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

75 mmHg suction

IVAC suction 75 mmHg

Group Type ACTIVE_COMPARATOR

75 mmHg suction

Intervention Type OTHER

Incisional Vacuum Assisted Closure (IVAC) Device, set to 75 mmHg suction throughout the duration of the IVAC use.

125 mmHg suction

IVAC suction 125 mmHg

Group Type EXPERIMENTAL

125 mmHg

Intervention Type OTHER

Incisional Vacuum Assisted Closure (IVAC) Device, set to 125 mmHg suction throughout the duration of the IVAC use.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

75 mmHg suction

Incisional Vacuum Assisted Closure (IVAC) Device, set to 75 mmHg suction throughout the duration of the IVAC use.

Intervention Type OTHER

125 mmHg

Incisional Vacuum Assisted Closure (IVAC) Device, set to 125 mmHg suction throughout the duration of the IVAC use.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subject is 18 years or older
* Subject has tibia fracture requiring treatment with BMP-2
* Subject to have an Incisional Vacuum Closure (IVAC) Device, placed on the skin directly over the BMP-2 implantation site
* Subject/guardian able to provide informed consent

Exclusion Criteria

* Subject is less than 18 years old
* Subject has a wound at fracture/surgical site that cannot be closed
* Subject/guardian unable to provide informed consent
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medtronic

INDUSTRY

Sponsor Role collaborator

University of Missouri-Columbia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Brett Crist

Assistant Professor, Co-Director of Trauma Services, Co-Director Trauma Fellowship, Department of Orthopaedic Surgery

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Brett D. Crist, MD

Role: PRINCIPAL_INVESTIGATOR

University of Missouri-Columbia

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Missouri

Columbia, Missouri, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IRB 1097637

Identifier Type: -