Trial Outcomes & Findings for Objective Testing of Tear Film Stability (NCT NCT00789529)

NCT ID: NCT00789529

Last Updated: 2013-05-31

Results Overview

The wettability index is derived from the slope of a metric developed to measure the regularity of the Shack-Hartmann wavefront sensor image. The more wettable a lens is the more stable the metric and the slope of the metric (the wettability index) is closer to zero. The more negative values indicate a less wettable the lens.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

32 participants

Primary outcome timeframe

2 weeks

Results posted on

2013-05-31

Participant Flow

Recruitment of patients was conducted by approaching the patients seen in the practice.

32 subjects were recruited and enrolled in the study. No subjects had to be excluded.

Participant milestones

Participant milestones
Measure
1 - ReNu MultiPlus First, Opti-Free RepleniSH Second
Used ReNu MultiPlus multi-purpose solution for the care of new contact lenses in the first intervention period, and used Opti-Free RepleniSH multi-purpose disinfecting solution for the care of new contact lenses in the second intervention period
2 - Opti-Free RepleniSH First, ReNu MultiPlus Second
Used Opti-Free RepleniSH multi-purpose disinfecting solution for the care of new contact lenses in the first intervention period, and used ReNu MultiPlus multi-purpose solution for the care of new contact lenses in the second intervention period
Overall Study
STARTED
16
16
Overall Study
COMPLETED
15
15
Overall Study
NOT COMPLETED
1
1

Reasons for withdrawal

Reasons for withdrawal
Measure
1 - ReNu MultiPlus First, Opti-Free RepleniSH Second
Used ReNu MultiPlus multi-purpose solution for the care of new contact lenses in the first intervention period, and used Opti-Free RepleniSH multi-purpose disinfecting solution for the care of new contact lenses in the second intervention period
2 - Opti-Free RepleniSH First, ReNu MultiPlus Second
Used Opti-Free RepleniSH multi-purpose disinfecting solution for the care of new contact lenses in the first intervention period, and used ReNu MultiPlus multi-purpose solution for the care of new contact lenses in the second intervention period
Overall Study
Withdrawal by Subject
0
1
Overall Study
Other Reason
1
0

Baseline Characteristics

Objective Testing of Tear Film Stability

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
1 - ReNu MultiPlus First
n=16 Participants
Used ReNu MultiPlus first, Opti-Free RepleniSH Second
2 - Opti-Free RepleniSH First
n=16 Participants
Opti-Free RepleniSH first, ReNu MultiPlus Second
Total
n=32 Participants
Total of all reporting groups
Age, Categorical
<=18 years
0 Participants
n=93 Participants
0 Participants
n=4 Participants
0 Participants
n=27 Participants
Age, Categorical
Between 18 and 65 years
16 Participants
n=93 Participants
16 Participants
n=4 Participants
32 Participants
n=27 Participants
Age, Categorical
>=65 years
0 Participants
n=93 Participants
0 Participants
n=4 Participants
0 Participants
n=27 Participants
Age Continuous
27.3 years
STANDARD_DEVIATION 3.8 • n=93 Participants
27.4 years
STANDARD_DEVIATION 5.1 • n=4 Participants
27.3 years
STANDARD_DEVIATION 4.4 • n=27 Participants
Sex: Female, Male
Female
13 Participants
n=93 Participants
14 Participants
n=4 Participants
27 Participants
n=27 Participants
Sex: Female, Male
Male
3 Participants
n=93 Participants
2 Participants
n=4 Participants
5 Participants
n=27 Participants
Region of Enrollment
United States
16 participants
n=93 Participants
16 participants
n=4 Participants
32 participants
n=27 Participants

PRIMARY outcome

Timeframe: 2 weeks

Population: Per protocol. All participants that completed both arms were analysed.

The wettability index is derived from the slope of a metric developed to measure the regularity of the Shack-Hartmann wavefront sensor image. The more wettable a lens is the more stable the metric and the slope of the metric (the wettability index) is closer to zero. The more negative values indicate a less wettable the lens.

Outcome measures

Outcome measures
Measure
Opti-Free® RepleniSH® MPDS
n=30 Participants
Used Opti-Free® RepleniSH® MPDS
Renu MultiPlus®
n=30 Participants
Used Renu MultiPlus®
Objective, In-vivo Soft Contact Lens Wettability Index
-1.82 wettability index
Standard Deviation 2.88
-1.98 wettability index
Standard Deviation 2.80

SECONDARY outcome

Timeframe: 2 weeks

Subject questionnaire response: Overall comfort at 2 weeks in a 0-50 point scale. 0=Very poor 50 = Excellent

Outcome measures

Outcome measures
Measure
Opti-Free® RepleniSH® MPDS
n=30 Participants
Used Opti-Free® RepleniSH® MPDS
Renu MultiPlus®
n=30 Participants
Used Renu MultiPlus®
Subject Questionnaire Response
42.7 units on a scale
Standard Deviation 7.3
43.1 units on a scale
Standard Deviation 5.0

Adverse Events

1 - ReNu MultiPlus First

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

2 - Opti-Free RepleniSH First

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Dr. George Zikos

Manhattan Vision Associates / Institute for Vision Research

Phone: 2126884277

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place

Restriction type: LTE60