Trial Outcomes & Findings for Technolas 217z Laser With Zyoptix Aspheric Algorithm Used for the LASIK Treatment of Myopia and Myopic Astigmatism. (NCT NCT00769808)
NCT ID: NCT00769808
Last Updated: 2020-09-11
Results Overview
COMPLETED
NA
72 participants
3 months
2020-09-11
Participant Flow
Seventy two myopic participants (144 eyes) were enrolled.
Participant milestones
| Measure |
Technolas 217z Excimer Laser
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Overall Study
STARTED
|
72
|
|
Overall Study
COMPLETED
|
64
|
|
Overall Study
NOT COMPLETED
|
8
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Technolas 217z Laser With Zyoptix Aspheric Algorithm Used for the LASIK Treatment of Myopia and Myopic Astigmatism.
Baseline characteristics by cohort
| Measure |
Technolas 217z Excimer Laser
n=65 Participants
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=5 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
65 Participants
n=5 Participants
|
|
Age, Categorical
>=65 years
|
0 Participants
n=5 Participants
|
|
Age, Continuous
|
32.0 years
STANDARD_DEVIATION 7.1 • n=5 Participants
|
|
Sex: Female, Male
Female
|
29 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
36 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
21 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
2 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
40 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
2 Participants
n=5 Participants
|
PRIMARY outcome
Timeframe: 3 monthsPopulation: There were 59 participants with visual acuity data available for analysis.
Outcome measures
| Measure |
Technolas 217z Excimer Laser
n=59 Participants
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Percentage of Eyes With Uncorrected High Contrast Distance Visual Acuity of 20/40 or Better
|
99.2 percentage of eyes
Interval 97.5 to 100.0
|
PRIMARY outcome
Timeframe: 3 monthsManifest refractions (eyeglass prescriptions) have three components: sphere, cylinder, and axis. Sphere and cylinder are both expressed in diopters, which is a continuous measure of the focusing power needed to make the image sharp on the retina. Manifest refraction spherical equivalent (MRSE) is equal to sphere + ½ x cylinder. It is expressed in diopters (D).
Outcome measures
| Measure |
Technolas 217z Excimer Laser
n=118 eyes
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Percentage of Eyes With Manifest Subjective Refraction (MRSE) Within ± 1.00 Diopter (D) and 0.50 D of Emmetropia
Within 0.50 D
|
109 eyes
|
|
Percentage of Eyes With Manifest Subjective Refraction (MRSE) Within ± 1.00 Diopter (D) and 0.50 D of Emmetropia
Within 1.00 D
|
117 eyes
|
PRIMARY outcome
Timeframe: Baseline, 3 monthsMean change in best-corrected high contrast distance visual acuity. Corrected means spectacle corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity. Acuity was averaged across visits.
Outcome measures
| Measure |
Technolas 217z Excimer Laser
n=118 eyes
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Preservation of Manifest Best Corrected High Contrast Distance Visual Acuity
|
-0.055 units on a scale
Standard Deviation 0.103
|
PRIMARY outcome
Timeframe: 3 monthsOutcome measures
| Measure |
Technolas 217z Excimer Laser
n=118 eyes
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Percentage of Eyes With Manifest Best-corrected Distance Photopic Visual Acuity Decrease of 2 or More Lines
|
1 eyes
|
PRIMARY outcome
Timeframe: 3 monthsManifest refractions (eyeglass prescriptions) have three components: sphere, cylinder, and axis. Sphere and cylinder are both expressed in diopters, which is a continuous measure of the focusing power needed to make the image sharp on the retina. Manifest refraction spherical equivalent (MRSE) is equal to sphere + ½ x cylinder. It is expressed in diopters (D).
Outcome measures
| Measure |
Technolas 217z Excimer Laser
n=118 eyes
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Percentage of Eyes With > 2.00 Diopter of Induced Postoperative Refractive Cylinder
|
0 eyes
|
PRIMARY outcome
Timeframe: 3 monthsCorrected means spectacle corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity. Acuity was averaged across visits.
Outcome measures
| Measure |
Technolas 217z Excimer Laser
n=118 eyes
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Percentage of Eyes That Had High Contrast Best Spectacle Corrected Visual Acuity (HCBSCVA) of 20/20 or Better at Baseline Had a Visual Outcome Worse Than 20/40 at 3 Months
|
0 eyes
|
SECONDARY outcome
Timeframe: Baseline, 3 monthsThe aberrations in the eye's optical system were measured over the entire pupil by the Bausch \& Lomb Zywave II WaveFront Aberrometer, a Hartmann-Shack type device. The pupil should have been at least 6 mm in diameter using 2.5% phenylephrine as a dilating agent to maximize the pupil diameter and hence the amount of wavefront information collected by the Zywave II. The wavefront data was then fitted with Zernike polynomials representing the 2nd, 3rd, 4th and 5th order Zernike terms. These terms represent the wavefront aberration of the eye.
Outcome measures
| Measure |
Technolas 217z Excimer Laser
n=118 eyes
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Percentage Change From Baseline in Higher Order Aberrations.
|
24.9 Percentage change
Standard Deviation 0.1413
|
Adverse Events
Technolas 217z Excimer Laser
Serious adverse events
Adverse event data not reported
Other adverse events
| Measure |
Technolas 217z Excimer Laser
n=66 participants at risk
Bausch \& Lomb Zyoptix Aspheric Algorithm for LASIK correction of myopia and myopic astigmatism.
Bausch \& Lomb 217z Excimer Laser: LASIK correction of myopia and myopic astigmatism
|
|---|---|
|
Eye disorders
Bowman's membrane disorder
|
12.1%
8/66 • 6 months
There were 66 treated participants evaluated for adverse events.
|
|
Eye disorders
Corneal edema
|
6.1%
4/66 • 6 months
There were 66 treated participants evaluated for adverse events.
|
|
Eye disorders
Keratitis
|
24.2%
16/66 • 6 months
There were 66 treated participants evaluated for adverse events.
|
|
Eye disorders
Punctate keratitis
|
54.5%
36/66 • 6 months
There were 66 treated participants evaluated for adverse events.
|
|
Eye disorders
Eye operation complication
|
31.8%
21/66 • 6 months
There were 66 treated participants evaluated for adverse events.
|
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place
Restriction type: OTHER